217
PRESSURE CONTROLS
Low Noise Type
Pilot Operated Relief Valves
C
Low Noise Type Pilot Operated Relief Valves
DIMENSIONS IN
MILLIMETRES (INCHES)
Mounting surface
S-BG-03: ISO 6264-AR-06-2-A
S-BG-06: ISO 6264-AS-08-2-A
S-BG-10: ISO 6264-AT-10-2-A
Valve Model Numbers
Japanese Std. "JIS" and European Design Std. N. American Design Std.
Socket Head Cap Screw
S-BG-03
S-BG-06
S-BG-10
Qty.
M12 40 Lg.
M16 50 Lg.
M20 60 Lg.
1/2-13 UNC 1-1/2 Lg.
5/8-11 UNC 2 Lg.
3/4-10 UNC 2-1/4 Lg.
4
4
4
Model Numbers
S-BG-03
S-BG-06
S-BG-10
76
(2.99)
163.5
(6.44)
A D
Dimensions mm (Inches)
B C E F H J K N P Q S T U V X Z
98
(3.86)
120
(4.72)
53.8
(2.12)
82.6
(3.25)
70
(2.76)
11.1
(.44)
18.7
(.74)
14
(.55)
26.9
(1.06)
41.3
(1.63)
35
(1.38)
53.8
(2.12)
88.9
(3.50)
66.7
(2.63)
73.6
(2.90)
46.1
(1.81)
58.8
(2.31)
26.9
(1.06)
44.9
(1.77)
33.7
(1.33)
180
(7.09)
163.5
(6.44)
13.5
(.53)
21.5
(.85)
17.5
(.69)
21
(.83)
32
(1.26)
26
(1.02)
50
(1.97)
65
(2.56)
50
(1.97)
130
(5.12)
167
(6.57)
130
(5.12)
103
(4.06)
135
(5.31)
103
(4.06)
21.5
(.85)
33.5
(1.32)
26
(1.02)
106
(4.17)
155
(6.10)
122
(4.80)
26.1
(1.03)
21.1
(.83)
19.3
(.76)
13
(.51)
18
(.71)
13
(.51)
36.1
(1.42)
21.3
(.84)
Z
Fully Extended
J
Mounting Surface
(O-Rings Furnished)
Locating Pin
6(.24)
Dia.
44(1.73)
Dia.
INC.
Pressure Adjustment Handle
Two Collars
Lock Nut
14(.55)
Dia.
U
V
X
T
Pressure Gauge Connection
"Y"
Thd
Vent Port
H
Tank Port
F
Fully Extended
Fully Extended
J
E
Pressure Port
C
D
B
A
S
Q
P
"K"
Dia. Through
"N"
Dia. Spotface
4 Places
6
(.24)
Attachment
Mounting Bolts
Instructions
S-BG-03-
*
-L-40/4090
Model Numbers
"Y"
Thd.
S-BG-03-
*
-
*
-40
S-BG-03-
*
-
*
-4090
S-BG-06-
*
-
*
-40
S-BG-06-
*
-
*
-4090
S-BG-10-
*
-40
S-BG-10-
*
-4090
Rc 1/4 = 1/4 BSP.Tr
1/4 NPT
Rc 1/4 = 1/4 BSP.Tr
1/4 NPT
Rc 1/4 = 1/4 BSP.Tr
1/4 NPT
Note:For dimensions of the valve mounting
surface, see the dimensional drawing
(
P. 213) of the sub-plate used together.
Note:For other dimensions, see the figures
shown left.
S-BG- -
*
-R
03
06
Opposite Handle Position
S-BG-06-
*
-L-40/4090
S-BG-10-
*
-40/4090
If a remote control relief valve is used in the vent circuit, see page 203. In addition, if the internal volume of the vent
line is too large, chattering is likely to occur. Thus, as far as possible reduce the inside Dia. and the length of the pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressures or anti-clock-
wise for lower pressures. After adjustments, do not forget to tighten the lock nut.
Piping of the tank line should not be connected to any tank line of the other valves, but connected directly to the reservoir.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is
equivalent to 10 MPa (1450 PSI).
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a flow rate above
5 L/min (1.3 U.S. GPM) and model 10 with 8 L/min (2.1 U.S. GPM).