PROPORTIONAL CONTROLS
Page PT46
W 50/2022
Via Malavolti, 36 - 41122 Modena - ITALY - Phone +39 (059) 254895 - Fax +39 (059) 253512 - mail: tecnord@tecnord.com - www.tecnord.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
EU-F2A 2 WAY PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR
DESCRIPTION
12 size, 1” 1/16-12 thread, “Tecnord” series, solenoid operated, normally closed, poppet style, restrictive type 2
ways pressure compensated proportional ow regulator.
OPERATION
EU-F2A maintains a constant ow rate out of (2) regardless of load pressure variations in the circuit downstream
of (1). When coil is not energized, there is no regulated ow out of (2). The valve begins to respond to load
variations when the ow through the valve creates a pressure differential across the control spool.
Reverse ow from (2) to (1) returns through the control spool and is not compensated. The manual override
increases ow by counter-clockwise rotation of the manual override knob.
FEATURES
• Hardened parts for long-life.
• Industry common cavity.
• Excellent linearity and low hysteresis characteristics.
• Cartridges are voltage interchangeable.
• Optional coil voltages and terminations available.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
Regulated Flow vs. Pressure
Flow vs. Current
1
2
3
Regulated Flow vs. Pressure
Flow vs. Current
1
2
3
Flow Range See curves for various versions
Max System Pressure 3500 PSI (241 bar)
Leakage 0-10 drops / min @ 245 bar
Hysteresis ±5%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -30°C / +100°C
Weight .72 lbs (.32 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 37 ft-lbs (50 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
Cavity TECNORD 3W
Cavity Tools Kit
(form tool, reamer, tap) 40500034
Current Supply Characteristics PWM (Pulse Width Modulation)
Rated Current Range 500-1400 mA
PWM or Super-Imposed
Dither Frequency 100 Hz
Coil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)
VALVE SPECIFICATIONS
COIL SPECIFICATIONS
Port (1) must be connected
in the manifold to port (3).
HYDRAULIC SYMBOL
PERFORMANCE
Regulated Flow vs. Pressure
Pressure Drop 1-2 bar
Regulated Flow (l/min)
2
3
PROPORTIONAL CONTROLS
Page PT47
W 50/ 2022
Via Malavolti, 36 - 41122 Modena - ITALY - Phone +39 (059) 254895 - Fax +39 (059) 253512 - mail: tecnord@tecnord.com - www.tecnord.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
Regulated Flow vs. Pressure
Flow vs. Current
1
2
3
DIMENSIONS
ORDERING INFORMATION
(for bodies style and sizes see section “Accessories”)
EU-F2A – – – –
OPTIONS BODIES
Buna Standard A0 Up to 55 l/min Blank Without Body
Buna, Screw Type Override (Knob) AS Up to 55 l/min N 3/4” BSP Ports
Buna, Screw Type Override (Grad. Knob) AK Up to 55 l/min S #8 SAE Ports
Buna Standard B0 Up to 75 l/min
Buna, Screw Type Override (Knob) BS Up to 75 l/min
Buna, Screw Type Override (Grad. Knob) BK Up to 75 l/min
VOLTAGE
12 12 VDC
Buna Standard C0 Up to 100 l/min 24 24 VDC
Buna, Screw Type Override (Knob) CS Up to 100 l/min
“F” COIL TERMINATION
Buna, Screw Type Override (Grad. Knob) CK Up to 100 l/min HC DIN 43650 (Hirschmann)
DI Deutsch-Integral DT04-2P
JT AMP Jr. Timer
Approximate Coil Weight: .47 lbs (.21 kg)
NOTE: for other seals, consult factory.








Flow vs. Current
Coil 12 VDC - Oil 26 cSt (121 SSU) @ 40°C (104°F)
Current (mA)
Flow (l/min)