EC-SNR-POS-75O-H SLIP-IN SPOOL POSITION TRANSDUCER
Operating voltage (VBATT): 6÷32 VDC
Max current consumption: <15mA
Operating temperature: -40°C / +85°C
Degree of protection: IP 67
Maximum operating pressure: 45 bar
Output signal (inactive): open collector (pnp)
Output signal (active): VBATT
Switching threshold: 1 mm
Maximum mechanical stroke: ±8 mm
Connector pins: 1 +V (POWER SUPPLY)
2 -V (POWER SUPPLY)
3 OUT A
4 OUT B
Connector type: Deutsch DT04-4P
SPECIFICATIONS
OUTPUT SIGNAL
DESCRIPTION
Position transducer based on Hall effect sensor to detect a movement
from the neutral (zero) position. Slip-in assembly.
OPERATION
The sensor provides two directional signal outputs, each output becomes
active when a movement is detected in its corresponding direction.
Outputs are active low. Two low outputs means fault. It can be used as
a safety device in conjunction with Tecnord’s MMS electronic units (e.g.
MMS 1521).
FEATURES
• Power supply line is protected against reversed polarity and
overvoltage.
• Output protected against short circuits to GND and supply.
• Redundant version (dual electronics) available.
• Electro Magnetic Compatibility (EMC): EN 61000-6-2 (Immunity)
EN 61000-6-3 (Emissions)
• 12 VDC and 24 VDC systems.
• Spool position detect for electrohydraulic manifolds.
APPLICATIONS
WARNING: The specifi cations/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specifi c application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone +39 059 254895 • Fax +39 059 253512 • E-mail: tecnord@tecnord.com
SENSORS - page 9
SENSORS
EC - SNR - POS - 75O - H Slip-In Spool position transducer
Descriptio
n
Position transducer based on Hall effect sensor to detect a movement from the neutral (zero) position. Slip-in assembly.
Operatio
n
The sensor provides two directional signal outputs,
Each output becomes active when a movement
is detected in its corresponding direction.
Outputs are active low. Two low outputs means fault.
It can be used as a safety device in conjunction
with Tecnord's MM
S
electronic units (e.g. MMS.1521).
Feature
s
Power supply line is protected against reversed polarity and overvoltage.
Output protected against short circuits to GND and supply.
Electro Magnetic Compatibility (EMC): EN 61000-6-2 (Immunity), EN 61000-6-3 (Emissions).
Redundant version (dual electronics) available.
Output Signa
l
Specification
s
Operating voltage (VBATT):
6 ÷ 32 Vdc
Max current consumption: <15mA
Operating temperature: -25 ÷ +105 °C
Degree of protection: IP 67
Maximum operating pressure: 35 bar
Output signal (inactive): open collector (pnp)
Output signal (active):
V
BATT
Switching threshold: 1 mm
Maximum mechanical stroke: ±8 mm
Connector type Deutsch DT04-4P
Connector pins: 1 OUT A
1 +V (POWER SUPPLY)
2 -V (POWER SUPPLY-GND)
4 OUT B
Dimension
s
Applications Ordering code:
12 Vdc and 24 Vdc systems
Spool position detect for electrohydraulic manifolds
DIMENSIONS
ORDERING CODE 20.0204.006