EC-SNR-POS-75O-H SLIP-IN SPOOL POSITION TRANSDUCER
Operating voltage (VBATT): 6÷32 VDC
Max current consumption: <15mA
Operating temperature: -40°C / +85°C
Degree of protection: IP 67
Maximum operating pressure: 45 bar
Output signal (inactive): open collector (pnp)
Output signal (active): VBATT
Switching threshold: 1 mm
Maximum mechanical stroke: ±8 mm
Connector pins: 1 +V (POWER SUPPLY)
2 -V (POWER SUPPLY)
3 OUT A
4 OUT B
Connector type: Deutsch DT04-4P
SPECIFICATIONS
OUTPUT SIGNAL
DESCRIPTION
Position transducer based on Hall effect sensor to detect a movement
from the neutral (zero) position. Slip-in assembly.
OPERATION
The sensor provides two directional signal outputs, each output becomes
active when a movement is detected in its corresponding direction.
Outputs are active low. Two low outputs means fault. It can be used as
a safety device in conjunction with Tecnord’s MMS electronic units (e.g.
MMS 1521).
FEATURES
• Power supply line is protected against reversed polarity and
overvoltage.
• Output protected against short circuits to GND and supply.
• Redundant version (dual electronics) available.
• Electro Magnetic Compatibility (EMC): EN 61000-6-2 (Immunity)
EN 61000-6-3 (Emissions)
• 12 VDC and 24 VDC systems.
• Spool position detect for electrohydraulic manifolds.
APPLICATIONS
WARNING: The specifi cations/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specifi c application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone +39 059 254895 • Fax +39 059 253512 • E-mail: tecnord@tecnord.com
SENSORS - page 9
SENSORS
EC - SNR - POS - 75O - H Slip-In Spool position transducer
Descriptio
Position transducer based on Hall effect sensor to detect a movement from the neutral (zero) position. Slip-in assembly.
Operatio
The sensor provides two directional signal outputs,
Each output becomes active when a movement
is detected in its corresponding direction.
Outputs are active low. Two low outputs means fault.
It can be used as a safety device in conjunction
with Tecnord's MM
electronic units (e.g. MMS.1521).
Feature
Power supply line is protected against reversed polarity and overvoltage.
Output protected against short circuits to GND and supply.
Electro Magnetic Compatibility (EMC): EN 61000-6-2 (Immunity), EN 61000-6-3 (Emissions).
Redundant version (dual electronics) available.
Output Signa
Operating voltage (VBATT):
6 ÷ 32 Vdc
Max current consumption: <15mA
Operating temperature: -25 ÷ +105 °C
Degree of protection: IP 67
Maximum operating pressure: 35 bar
Output signal (inactive): open collector (pnp)
Output signal (active):
V
BATT
Switching threshold: 1 mm
Maximum mechanical stroke: ±8 mm
Connector type Deutsch DT04-4P
Connector pins: 1 OUT A
1 +V (POWER SUPPLY)
2 -V (POWER SUPPLY-GND)
4 OUT B
Dimension
Applications Ordering code:
12 Vdc and 24 Vdc systems
Spool position detect for electrohydraulic manifolds
DIMENSIONS
ORDERING CODE 20.0204.006