MODEL
RVED8RVED8
Ventable, pilot-operated, balanced piston relief main stage with
integral T-8A control cavity and drain to port 4
SERIESSERIES 2 / 2 / CAPACITY:CAPACITY: 120 L/min. / 120 L/min. / CAVITY:CAVITY: T-22A T-22A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a normally closed modulating element that incorporates an integral pilot control
cavity. It is ventable, externally drained, and is a balanced piston design. The pilot control
cavity will accept any T-8A pressure control cartridge. When the pressure at the inlet (port 1)
reaches the pilot control cartridge setting, the modulating element starts to open to tank
(port 2), throttling flow to regulate the pressure. The pilot cartridge's setting determines the
difference in pressure between the inlet (port 1) and the drain (port 4). The vent port (port 3)
that tees in between the main piston and pilot control cartridge, allows the modulating
element to also be controlled by remote pilot or 2-way valves.
TECHNICAL DATATECHNICAL DATA
Cavity T-22A
Series 2
Capacity 120 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Pilot Control Cavity T-8A
Pilot Control Valve Installation Torque 27 - 33 Nm
Pilot Control Valve Hex Size 22,2 mm
Main stage leakage at 110 SUS (24 cSt) 50 cc/min.@70 bar
Response Time - Typical 10 ms
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990022007
Seal kit - Cartridge EPDM: 990022014
Seal kit - Cartridge Polyurethane: 990022002
Seal kit - Cartridge Viton: 990022006
Model Weight 0.26 kg.
sunhydraulics.com/model/
RVED8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered
c
2025 Sun Hydraulics 2 of 3
(W)(W)
MINIMUM CONTROL PRESSUREMINIMUM CONTROL PRESSURE
WW 100 psi (7 bar)
DD 25 psi (1,7 bar)
(N)(N)SEAL MATERIALSEAL MATERIAL
NN Buna-N
EE EPDM
VV Viton
TECHNICAL FEATURESTECHNICAL FEATURES
Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
Main stage orifice is protected by a 150-micron stainless steel screen.
Not suitable for use in load holding applications due to spool leakage.
Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control
valve should then be installed into the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity.
These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation.
See Pilot Control Cartridges.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids,
greases and lubricants will damage the seals.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation
torque and/or cavity/cartridge machining variations.
PERFORMANCE CURVESPERFORMANCE CURVES
separately and assembled at point of use.
NOTESNOTES