c
2025 Sun Hydraulics 1 of 2
MODEL
DMUT
3-way, direct-acting, balanced spool, solenoid-operated directional valve, 3000
psi (210 bar) - common cavity
SERIES 1C / CAPACITY: 28 L/min. / CAVITY: SC-10-03
(X)CONTROL
X -
(H)SPOOL CONFIGURATION
H Normally Open 1 to 2, Closed 1 to 3
(N)SEAL MATERIAL
N Buna-N
COIL *
No coil
* Additional coil options are available
X-Control, H-Spool
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool directional valve.
This valve is designed to be used with the 780 Series coils.
TECHNICAL DATA
Cavity SC-10-03
Series 1C
Capacity 28 L/min.
Maximum Operating Pressure 210 bar
Typical Valve Leakage at 110 SUS (24cSt) 39 cc/min.@210 bar
Response Time - Typical 50 ms
Switching Frequency 15,000 max. cycles/hr
Solenoid Tube Diameter 12,7 mm
Valve Hex Size 25 mm
Coil Nut Torque 4,8 - 5,3 Nm
Valve Installation Torque 32,5 - 37,9 Nm
Model Weight 0.11 kg.
sunhydraulics.com/model/
DMUT
Model Code Example: DMUTXHNCONFIGURATION OPTIONS
c
2025 Sun Hydraulics 2 of 2
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 3000 psi (210 bar) service.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
All ports are rated to a maximum operating pressure of 3000 psi (210 bar).
This valve features zinc plating on exposed surfaces.
Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
The cartridge installation torque of 26 lbf ft (35 Nm) should be respected for best performance.
The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a
factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes
that will affect the function of the cartridge.
Coils can be mounted on the tube in either direction.
PERFORMANCE CURVES