2026 Sun Hydraulics 1 of 2
MODEL
COFOCOFO
120:1 ratio, pilot-to-close check valve
SERIESSERIES 2 / 2 / CAPACITY:CAPACITY: 4 L/min. (1,3 mm) / 4 L/min. (1,3 mm) / CAVITY:CAVITY: T-2A T-2A
(X)(X)CONTROLCONTROL
XX Standard Pilot
(D)(D)MINIMUM PILOT PRESSUREMINIMUM PILOT PRESSURE
DD 60 psi (4 bar)
(N)(N)SEAL MATERIALSEAL MATERIAL
NN Buna-N
VV Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a pilot-to-close check cartridge that has a 120:1 pilot ratio. The valve is designed
specifically to discharge an accumulator when the pump is turned off. With no pressure at
the pump port (port 3), the valve is open between the accumulator (port 1) and tank (port 2).
60 psi (4 bar) at port 3 will close the valve for accumulator pressures up to 5000 psi (350 bar).
When pump pressure at port 3 is below 300 psi (20 bar) there is a leak path from port 3 to
tank (port 2) to ensure accumulator discharge when the pump is turned off. When pump
pressure is above 300 psi (20 bar) the leak path closes for efficiency.
TECHNICAL DATATECHNICAL DATA
Cavity T-2A
Series 2
Capacity 4 L/min. (1,3 mm)
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,3 cc/min.
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990202007
Seal kit - Cartridge Polyurethane: 990002002
Seal kit - Cartridge Viton: 990202006
Model Weight 0.22 kg.
sunhydraulics.com/model/
COFO
Model Code Example: COFOArrayModel Code Example: COFOArrayCONFIGURATION OPTIONSCONFIGURATION OPTIONS
c
2026 Sun Hydraulics 2 of 2
TECHNICAL FEATURESTECHNICAL FEATURES
Features hardened steel seats for excellent wear characteristics and contamination tolerance.
Note: The discharge of the accumulator is across an .05 inch (1,27 mm) diameter orifice. The discharge time for large accumulators
with low pre-charge pressures may be too long. In this case there are 2-valve circuits that greatly increase the capacity. See the Tech
Tips (FAQs).
The valve is a poppet design that results in very low leakage of stored fluid from the accumulator.
Leakage of the pump signal only occurs when the pump is unloaded to below 300 psi (20 bar).
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation
torque and/or cavity/cartridge machining variations.