12-43
SCPSD UK.INDD 17.07.23
Electronic Pressure Switch
Series SCPSD
12
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Technical Data
Input quantities
Reversing cycles ≥ 100 Mio.
Scanning rate ≥ 5 ms
Connecting thread G1/4 BSPP;
ED soft seal NBR
1)
(DIN 3852 T2, form X);
ED (DIN3852 T11, form E)
Torque 35 Nm
Parts in contact with media Low pressure:
1.4404 stainless steel;
AL2O3 ceramic; NBR
high pressure:
stainless steels 1.4404; 1.4542
Temperature range of me-
dium
-20 …+85 °C
Weight approx. 300 g
Output quantities
Accuracy ± 0.5 % FS typ.; ± 1 % FS max.
Temperature drift ± 0.02 % FS/°K typ. (at -20…+85 °C)
± 0.03 % FS/°K max.
Long-term stability ± 0.2 % FS/a
Repeat accuracy ± 0.25 % FS
Switching point accuracy ± 0.5 % FS typ.; ± 1 % FS max.
Display accuracy ± 0.5 % FS typ. ± 1 Digit
± 1 % FS max. ± 1 Digit
Response speed
Switching output ≤ 10 ms
Analogue output ≤ 10 ms
Electrical connection
Power supply 15…30 VDC nominal
24 VDC; protection class 3
Electrical connection M12x1; 4-pole; 5-pole
with gold-plated contacts.
appliance inlet connector
DIN EN 175301-803 form A
(formerly DIN43650)
Short circuit protection yes
Reverse polarity protection yes
Overload protection yes
Current consumption < 100 mA
Housing
directionally adjustable up to 290°
Material pressure die-casting Z 410; painted
Foil material polyester
Display 4-gure 7-segment LED;
red; digit height 9 mm
Protection class IP67 DIN EN 60529;
IP65 with plug-in connector
DIN EN 175301-803 form A
(formerly DIN43650)
Environmental conditions
Environmental temperature
range
-20…+85 °C
Storage temperature range -40…+100 °C
Vibration resistance 20 g; 10…500 Hz
IEC60068-2-6
2)
Shock resistance 50 g; 11 ms
IEC60068-2-29
2)
EM compatibility
Interference emissions EN 61000-6-3
Interference resistance EN 61000-6-2
Outputs
Switching outputs 2 MOSFET high side switches (PNP)
Contact functions normally open/normally closed;
window/hysteresis;
freely settable function
Switching voltage Power supply - 1.5 VDC
Switching current max. 0.5 A per switch
Short circuit current 2.4 A per switch
Analogue output 0/4…20 mA; programmable;
freely scalable;
RL ≤ (power supply - 8 V)/
20 mA (≤ 500 Ω)
1)
Other sealing materials (FPM, EPDM etc.) on request.
2)
Does not apply to DIN EN 175301-803 form A (formerly DIN43650) version.
SCPSD 004 010 016 060 100 250 400 600
Pressure range
P
n
(bar)
-1...4 -1…10 -1...16 0…60 0…100 0…250 0…400 0…600
Overload pressure
P
max
(bar)
10 20 40 120 200 500 800 1200
Burst pressure
P
burst
(bar)
12 25 50 550 800 1200 1700 2200
Measuring element
Ceramic
low pressure
DMS thin lm
high pressure