10
10-8
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Characteristics
Pilot operated pressure reducing valves for in-line mount-
ing series R4R have a similar design to the subplate
mounted R4R series. For single functions – where no
manifold blocks are used – the valves can be directly
placed in the pipework.
The valves are available with 2 ports (L-body) or with 3
ports (T-body).
Features
• Pilot operated with manual adjustment
• Normally closed to avoid undesired motion
• 2 interfaces
- L-body (R4R06-G¾", R4R10-G1¼")
- T-body (R4R03-G½", R4R06-G1")
• 3 pressure stages
• 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
• With optional vent function
R4R10 L-body
R4R06 L-body
R4R
5
2
B
10
10-9
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Drain line
ext. from
pilot head
(Y1)
Ordering Code
Code Seal
1 NBR
5 FPM
Code Nominal size
03 NG10 (G½")
06
NG25
(G1" - T-body,
G¾" - L-body)
10 NG32 (G1¼")
Max.
pressure
350 bar
Pressure
stages
Pressure
reducing
valve
Design
series
Seal OptionsNominal
size
Body
Code Body
6
R4R03 T-body
R4R06 T-body
D
R4R06 L-body
R4R10 L-body
Code Pressure stages
1 up to 105 bar
3 up to 210 bar
5 up to 350 bar
Adjust-
ment
Switching
type
Solenoid
voltage
Code Adjustment
1 Hand knob
3
Acorn nut
with lead seal
4 Cylinder lock
Code Solenoid voltage
omit
Standard w/o
vent function
G0R 12 V=
G0Q 24 V=
GAR
1)
98 V=
GAG
1)
205 V=
W30
110 V / 50 Hz
120 V / 60 Hz
W31
230 V / 50 Hz
240 V / 60 Hz
1)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
Code Switching type
omit Standard w/o vent function
09
Solenoid not activated,
pressure reducer non-active
11
Solenoid activated
pressure reducer non-active
10
10-10
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
General
Design
T-body L-body
Size
03 (½") 06 (¾") 06 (1") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 4.9 5.0 7.3 8.3
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350; Ports B and Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm
2
/s] 20...400
Viscosity recommended [cSt] / [mm
2
/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
G0R G0Q GAR GAG W30 W31
12 V = 24 V = 98 V = 205 V =
110 at 50 Hz
120 at 60 Hz
230 at 50 Hz
240 at 60 Hz
±10 ±10 ±10 ±10 ±5 ±5
2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Supply voltage
[V]
[V]
Tolerance supply voltage [%]
Current consumption hold [A]
in rush [A]
Power consumption hold [W]
in rush [W]
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm
2
] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical Data
R4R
R4R with vent function
General
Design
T-body L-body
Size
03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 3.2 3.3 5.6 6.6
Hydraulic
Max. operating pressure [bar] Ports A, B and X: 350; Port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt]/[mm
2
/s] 20...400
Viscosity recommended [cSt]/[mm
2
/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
10
10-11
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Characteristic Curves
Reduced pressure pA versus flow Q
R4R03
1)
Reduced pressure pA versus flow Q
R4R06
1)
Reduced pressure pA versus flow Q
R4R10
1)
Minimum pressure curve
1)
Measured at 350 bar primary pressure pB.
Minimum pressure curve
Minimum pressure curve
Pressure p [bar]
5
0
10
15
20
25
30
10050 150
Flow Q [l/min]
5
0
15
10
25
20
30
25015050 100 200 300 350
Flow Q [l/min]
Pressure p [bar]
Pressure p [bar]
10
0
20
30
40
50
60
100 200 300 400 500
Flow Q [l/min]
70
80
All characteristic curves measured with HLP46 at 50 °C.
10
10-12
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Dimensions
NG Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 L1 L2 L3
03 T-body 85 – – – 27.5 59.5 97.5 – – – 53 92 –
06 T-body 136 – – – 38 93 131 – – – 66.5 117.5 –
06 L-body – 81 76 43 – – – 51 81 119 – – 49
10 L-body – 120.7 85.8 77.8 – – – 50.8 96 134 – – 49.8
Ports Function
Port size
R4V03 T-body R4V06 L-body R4V06 T-body R4V10 L-body
B pressure (inlet) G½ " G¾ " G1 " G1¼ "
A pressure (outlet) G½ " G¾ " G1 " G1¼ "
X1 external remote control or vent connection G¼ " G¼ " G¼ " G¼ "
Y1 external drain G¼ " G¼ " G¼ " G¼ "
T-body L-body
Seal kits
NG NBR FPM
03 S26-58507-0 S26-58507-5
06 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
10
10-13
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
51.8
70
15
Y1X1
Y1
143 max.
60.3
85
47
Vent valve
Main valve
Pilot valve
X1
38.6
R4R with vent function
Dimensions
Code External drain
11
B
A
X
Y1
Z
XY
09
B
A
X
Y1
Z
XY
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5