Measuring critical
system parameters
is essential
Reliable and continuous
control of the filter in all
applications
The Low Pressure range of filter
condition indicators are designed for
use on a wide range of Parker filters
and competitive interchange filters.
A comprehensive range of high quality
indicators for mobile, industrial and
marine applications.
Ideal for giving accurate electrical
feedback of filter clogging condition
in order to facilitate effective
maintenance and ensuring hydraulic
systems, marine/mobile or industrial
are protected from particulate
contamination.
Product Features:
• The Low Pressure range of filter condition indicators,
designed for use on a wide range of Parker filters.
• Accurate electrical filter clogging feedback.
Applications.
• Mobile, industrial and marine equipment
Pressure Switches
Low Pressure Switch
Contact Information:
Parker Hannifin
Hydraulic & Fuel Filtration EMEA
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parker.com/hffe
1/8” G.cyl.
9
22,2
48,9
16
3
84
1/8” G.cyl
PG7
16
22,2
9 3
63,9
Specification
LPS S1
Weight:
70 gram
Maximum working pressure:
40 bar
Connections:
Thread option G1/8.
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
N.O. Normally open
Max Voltage:
48V
Max. switched current
0.5 A
Protection degree
IP00
Protective cap:
Rubber IP54
For more information please see our
preferred part number table below.
Specification
LPS S1 - with connector PG7
Weight:
140 gram
Maximum working pressure:
40 bar
Connections:
Thread option G1/8.
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
N.O. Normally Open
Max Voltage:
48V
Max. switched current
0.5 A
Protection degree
IP00
Protective connector:
IP65
For more information please see our
preferred part number table below.
Pressure Switches
Low Pressure Switch - LPS S1
Parker S1 = 42 V Normally Open preferred part numbers
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS1EBG02MRP1 LPS S1 E B G02 M RP 1
LPSS1IBG02MRP1 LPS S1 I B G02 M RP 1
Parker S1 with PG7
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS1EBG02MPP1 LPS S1 E B G02 M PP 1
1
1/8”G.cyl.
22,2
9
48,9
16
3
84
Specification
LPS S2
Weight:
70 gram
Maximum working pressure:
40 bar
Connections:
Thread option G1/8
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
N.C. Normally Closed
Max Voltage:
48V
Max. switched current
0.5 A
Protection degree
IP00
Protective cap:
Rubber IP54
For more information please see our
preferred part number table below.
Preferred Part Numbers (S2 = 42V Normally Closed N.C.):
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS2EBG02MRP1 LPS S2 E B G02 M RP 1
Specification
LPS S2 - with connector PG7
Weight:
140 gram
Maximum working pressure:
40 bar
Connections:
Thread option G1/8.
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
N.C. Normally Closed
Max Voltage:
48V
Max. switched current
0.5 A
Protection degree
IP00
Protective connector:
IP65
For more information please see our
preferred part number table below.
Parker S2 with PG7
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS2EBG02MPP1 LPS S2 E B G02 M PP 1
Pressure Switches
Low Pressure Switch - LPS S2
2
M10x1
~60
25
9 3
97,8
Specification
LPS S3
Weight:
115 gram
Maximum working pressure:
40 bar
Connections:
Thread M10
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
Change over SPDT contacts
Max Voltage:
24Vdc/250 Vac
Max. switched current
2(1)A/6(1)A
Protection degree
IP00
Protective cap:
Rubber IP54
For more information please see our
preferred part number table below.
Preferred Part Numbers (S3 = 42V Change Over):
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS3HBM20MRP1 LPS S3 H B M10 M RP 1
LPSS3BBM10MRP1 LPS S3 B B M10 M RP 1
LPSS3EBM10MRP1 LPS S3 E B M10 M RP 1
Pressure Switches
Low Pressure Switch - LPS S3
3
Specification
LPS S6
Weight:
190 gram
Maximum working pressure:
150 bar
Connections:
Thread option G1/8.
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
Change over SPDT contacts
Max Voltage:
250V
Max. switched current
5 (1) A
Protection degree
IP00
Protective connector:
IP65
For more information please see our
preferred part number table below.
Specification
LPS S6
Weight:
140 gram
Maximum working pressure:
40 bar
Connections:
Thread option M10 or G1/8.
Mounting Torque:
Max. 8Nm
Temperature:
up to 100°C
Electrical contact:
Change over SPDT contacts
Max Voltage:
250Vac, 30Vdc
Max. switched current
5 (1) A, 4 (3) A
Protection degree
IP00
Protective connector:
IP65
For more information please see our
preferred part number table below.
1/8”G. cyl
Hexagon key 27mm
42
9
61
78
30x30
PG11 cable 6-8/8-10
M10x1 cyl
PG11 CABLE 6-8 / 8-10
25
10 3
85
Preferred Part Numbers (S6 = 250V Change Over):
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS6EBG02APCR1 LPS S6 E B G02 A PCR 1
Preferred Part Numbers (S6 = 250V Change Over):
Part number Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
LPSS6EBM10MPC1 LPS S6 E B M10 M PC 1
LPSS6BBM10MPC1 LPS S6 B B M10 M PC 1
Pressure Switches
Low Pressure Switch - LPS S6
4
Pressure Switches
Low Pressure Switch
Ordering Information
Features & Benefits
Product configurator
Box 3
Code
B
On request
Seal material
Buna/Nitrile
Fluorelastomer (Viton)
Seal type
Box 4
Box 6
Box 5
Code
A
M
Indicator body
Aluminium (Only LPSS6 + rotating system)
Brass
Indicator body
Code
LPS
Indicator series
Low Pressure Switch
Code
Box 1
Code
B
E
H
I
Indicator setting
0.7 bar (10 psi)
1.2 bar (17 psi)
1.5 bar (21 psi)
2.0 bar (29 psi)
Indicator setting
Protective cap and connectors
Rubber Protective cap (Box 2: only S1-S3)
Protective Connector PG7 (Box 2: only S1-S3)
Protective Connector PG11 (Box 2: only S1-S3)
Protective Connector PG11 Rotating 360°
system (Box 2: only S6)
Deutsch Conn. DT04-2P (Box 2: only S1-S3)
Connector AMP Junior timer (Box 2: only S1-S3)
Protection
Protection degree
IP54
IP65
IP65
IP65
IP67
IP67
Box 7
Options
Standard
Other options
Options
Code
1
factory supplied
Box 8
Thread connection
M10x1 Cylindrical
G1/8 Cylindrical
Thread connection
Code
M10
G02
Code
S1
S2
S3
S6
Electrical contacts
Normally Open (NO) Max. 42 V.
Normally Closed (NC) Max. 42 V.
Electrical Change over (SPDT) Max. 40 V.
Electrical Change over (SPDT) Max. 250 V.
Filter type
Box 2
Code
RP
PP
PC
PCR
D2
JT
Box 1
LPS
Box 2
S3
Box 3
E
Box 4
B
Box 5
M
Box 6
G02
Box 7
RP
Box 8
1
Parker Hannifin Ltd.
Hydraulic & Fuel Filtration EMEA
Email: ltrationinfo@parker.com
www.parker.com/hffe
FDHB622UK 04/2017 _RevD - ME© 2017 Parker Hannin Corporation. All rights reserved.
Features Advantages Benefits
Indicators fatique test to full
pressure rating
Reliable indicators for a wide range
of applications
Reliable and continuous control of the
filter in all apllications
Screw-in type indicators Easy mounting Reliable sealing, no leakage
Several indication settings Optimized for each bypass setting Right indicator setting for application
5