GMF iprotect
®
Medium Pressure Filters
Max. 600 I/min - 70 bar
Product Features:
The patented element design guarantees the quality of
filtration, wich directly impacts the oil cleanliness level as the
usage of pirate type after market filters with unknown quality
of filter media is excluded. This in-build safety has a direct,
positive impact on the productivity and profitability of
equipment.
• Guaranteed quality of filtration
• More compact solutions are possible
• Filter element remains in filter bowl during filter service
• Reduce waste over 50% thanks to re-usable element core
• No risk of installation mistake due to a 'foolproof' design
• Unique OEM branding opportunities
• Easy to intergrate into hydraulic manifold solutions
Contact Information:
Parker Hannifin
Hydraulic Filter Division Europe
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parker.com/hfde
A compact, cost
effective medium
pressure filter
Designed with the
iprotect
®
patented filtration
technology
The Parker GMF iprotect
®
is designed
to provide high quality filtration of
hydraulic systems, providing new
possibilities to reduce the cost
of ownership by improving the
productivity and profitability.
A new patented design of the filter
element ensures the quality of filtration
is secured.
With less space available for
filters, Parker has taken on board
the requirements to provide more
compact solutions. A unique feature
is the filter element remains inside the
filter bowl when changing the filter
element. This can save over 500 mm
of space envelope in comparison with
traditional medium pressure filters.
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
1
GMF iprotect
®
Typical Applications
Compressor lube oil
Off-line filter loops
Machine tools (Automotive standard)
Hydrostatic drive charge pumps
Mobile equipment
Pilot lines for servo controls
Oil patch drilling equipment
Injection moulding
The Parker Filtration GMF iprotect
®
Series
Medium Pressure Filters.
This partial list of applications for Parker “GMF” Series
Filters has a common factor, the need for an economical,
medium pressure range filter with excellent fatigue
pressure ratings. Prior to the availability of the “GMF”
filter, applications such as those listed were restricted by
limitations of a spin-on can, or forced into the higher-cost
range of high pressure filters.
The “GMF” Series fills this gap and is now available with
environmentally friendly iprotect
®
elements.
Features & Benefits
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
Features Advantages Benefits
Patented filter element Avoid use of non-genuine
parts
Guaranteed quality of
filtration
Filter element remains in
filter bowl
Less space needed to
change/service filter
More compact solutions
are possible
Environmental-friendly
design
Re-usable filter element
core located in filter bowl
Reduces environmental
waste over 50%
Service-friendly product
design
No handling of loose
re-usable parts
Reduce service time for
filter over 40%
Wide range of differential
pressure indicators
Continuous feedback of
condition filter elements
Optimized filter element life,
contributes to scheduled
maintenance
2
Specification
Filter element:
Degree of filtration:
Quantumfiber™ filter media, determined by Multipass-test according
to ISO16889
iprotect
®
QI
Supported with epoxy coated metal wire mesh, end cap material
reinforced composite. Collapse pressure rated at 20 bar (ISO 2941)
Indicator options (all with SAE8 thread):
- visual M3. - electrical T1.
- electronic F1(PNP). - electronic F2(NPN).
For indicator details see seperate indicator brochure.
Weights (kg):
Model Length 1 Length 2
GMF size 2 1.1 1.6
GMF size 3 2.0 2.5
GMF size 4 5.6 6.9
Fluid compatibility:
Suitable for use with mineral and vegetable oils, and some synthetic
oils. For other fluids, please consult Parker Filtration.
Pressure ratings:
Maximum allowable operating pressure: 70 bar
Rated fatigue pressure: 56 bar
Connections:
Several threaded port options available, flange faced ports available
on GMF size 4.
Connection style Model
GMF size 2 GMF size 3 GMF size 4
BSPF(G) 1”,
3
/4” 1
1
/4”, 1
1
/2” 1
1
/2”, 2”
SAE 12, 16 16, 24 24, 32
Metric 3000-M 2”
Filter housing:
Head material aluminium.
Bowl material hard anodized aluminium.
Seal material:
Nitrile or fluoroelastomer.
Operating temperature range:
Seal material Nitrile: -20°C to +100°C.
Seal material Fluoroelastomer: -20°C to +120°C.
Bypass valve & indicator settings:
Table following gives bypass valve and corresponding indicator setting.
Bypass Indicator
1.7 bar 1.2 bar
3.5 bar 2.5 bar
6 bar 5 bar
H
J
F
G
N
K
I
L
GMF size 3
Length 1
A
Length 2
B
Element removal
clearance
35mm (1,4”)
SAE - 4
Drain plug
25.4 (1.00)
Nominal Hex
P
D
C
M
E
GMF size 4
H
J
G
L
K
F
I
N
SAE - 4
Drain plug
P
25.4 (1.00)
Nominal Hex
E
C
D
M
Length 1
A
Length 2
B
Element removal
clearance
40mm (1,6”)
H
I
F
G
L
J
K
N
D
C
E
Length 1
A
Length 2
B
P
SAE - 4
Drain plug
Element removal
clearance
30mm (1,2”)
25.4 (1.00)
Nominal Hex
GMF size 2
M
GMF size 2
GMF size 3
GMF size 4
156.6
(6.17)
170.8
(6.73)
280.9
(11.06)
250.7
(9.87)
262.4
(10.33)
401.6
(15.81)
46.5
(1.83)
62.0
(2.44)
77.7
(3.06)
25.4
(1.09)
32.6
(1.28)
49.5
(1.95)
71.1
(2.80)
107.2
(4.22)
124.8
(4.91)
85.9
(3.38)
127.0
(5.00)
158.7
(6.25)
73.2
(2.88)
111.0
(4.37)
82.6
(3.25)
82.6
(3.25)
121.9
(4.80)
151.4
(5.96)
38.1
(1.50)
62.0
(2.44)
101.6
(4.00)
22.9
(0.90)
31.8
(1.25)
41.1
(1.62)
42.9
(1.69)
58.8
(2.32)
79.4
(3.12)
36.6
(1.44)
60.2
(2.37)
41.3
(1.63)
53
53
69
4xM6-1.0x7.9 deep
4xM8-1.25x13 deep
4xM8-1.25x16 deep
20-27 Nm
57-68 Nm
80-95 Nm
Dimensions in mm (inch)
Model A B C D E F G H I J K L M* N P
*Note: add 45mm for T and F indicators
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
3
GMF size 4 Flange Face Details (SAE 2” 3000-M)
38.9
77.8
21.4
42.8
Flange face
mounting holes
M12-1.75 x 22 deep
Pressure Drop Curves
With 1.7 bar bypass the recommended initial pressure drop is max 0.5 bar.
With 3.5 bar bypass the recommended initial pressure drop is max 1.0 bar.
With 6.0 bar bypass the recommended initial pressure drop is max 2.0 bar
If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:
The total Dp = housing Dph + (element Dpe x working viscosity/30).
Pressure drop curves based on 30 cSt
0 20 40 60 80 100 120
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
G
02QI 05QI
10QI
20QI
MF2 1 elements
Q [l/min]
[ ]∆p bar
0 20 40 60 80 100 120
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF2 2 elements
Q [l/min]
[ ]Dp bar
02QI
05QI
10QI
20QI
0 20 40 60 80 100 120
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF2 housing
Q [l/min]
[ ]p bar
G3/4"
G1"
GMF iprotect
®
Medium Pressure Filters
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
4
Pressure drop curves based on 30 cSt
Pressure Drop Curves
0 50 100 150 200 250 300 350 400
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF3 1 elements
Q [l/min]
[ ]p bar
∆
02QI 05QI 10QI
20QI
0 100 200 300 400 500 600
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF4 1 elements
Q [l/min]
[ ]p bar
∆
02QI
05QI
10QI
20QI
0 50 100 150 200 250 300 350 400
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF3 2 elements
Q [l/min]
[ ]p bar
02QI
05QI
10QI
20QI
∆
0 100 200 300 400 500 600
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF4 2 elements
Q [l/min]
[ ]p bar
∆
02QI
05QI
10QI
20QI
0 50 100 150 200 250 300 350 400
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF3 housing
Q [l/min]
[ ]p bar
∆
G1¼" G1½"
0 100 200 300 400 500 600
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
PRESSURE DROP CURVE
GMF4 housing
Q [l/min]
[ ]p bar
∆
G1¼"
G1½"
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
5
8
3a
3b
2
6
5
4
7
1
9
9
Element Service
A. Stop the system’s power unit.
B. Relieve any system pressure in the filter line.
C. Drain the filter bowl if drain port option is provided.
D. Loosen and remove bowl.
E. Remove filter from filter bowl.
F. Check bowl o-ring and dust seal for damage and
replace if necessary.
G. Lubricate element o-ring with system fluid and drop
in filter bowl with a rotational movement of the filter
element.
H. Install bowl by rotating clockwise and tighten to
specified torque.
GMF size 2 – 20-27 Nm (15-20ft. lbs)
GMF size 3 – 57-68 Nm (42-50ft. lbs)
GMF size 4 – 80-95 Nm (60-70ft. lbs)
I. Confirm there are no leaks after powering the system.
Head
Indicators with SAE 8 thread (code S08)
M3-visual auto reset: 1.2 bar
M3-visual auto reset: 2.5 bar
M3-visual auto reset: 5.0 bar
T1-electrical: 1.2 bar c/w DIN 43650 connector
T1-electrical: 2.5 bar c/w DIN 43650 connector
T1-electrical: 5.0 bar c/w DIN 43650 connector
F1-electrical PNP with 4 LEDs: 1.2 bar/2.5 bar/5.0 bar, NO type switch
F2-electrical NPN with 4 LEDs: 1.2 bar/2.5 bar/5.0 bar, NO type switch
F3-electrical PNP with 4 LEDs: 1.2 bar/2.5 bar/5.0 bar, NC type switch
F4-electrical NPN with 4 LEDs: 1.2 bar/2.5 bar/5.0 bar, NC type switch
Bypass valve
1.7 bar assembly
3.5 bar assembly
6,0 bar assembly
Element (see replacement element part numbers)
Bowl
Single length with drain
Single length without drain
Double length with drain
Double length without drain
Bowl and dust seal
Nitrile
Fluoroelastomer
Drain plug: SAE-4
Nitrile
Fluoroelastomer
Element seals are supplied with pos 5
1
2
3a
3b
4
5
6
7
8
9
Index
Description
GMF Filters Parts List
GMF iprotect
®
Series
Medium Pressure Filters
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
6
Ordering Information (cont.)
Product Configurator
Box 1
GMF2
Box 2
2
Box 3
10QI
Box 4
B
Box 5
T1
Box 6
K
Box 7
G16
Box 8
4
Code
1
2
Length
Length 1
Length 2
Filter type
Box 2
Code
GMF 2
GMF 3
GMF 4
Model
Small size MP filter, T-port
Medium size MP filter, T-port
Large size MP filter, T-port
Code
Box 1
Item is standard
Item is standard green option
Item is semi standard
Item is non standard
123
123
123
123
Highlights Key (Denotes part number availability)
Code
* Fluoroelastomers are available under various registered trademarks,
including Viton (a registered trademark of DuPont) and Fluorel (a registered
trademark of 3M)
02QI
30
60
70
150
200
350
05QI
40
80
90
180
250
400
10QI
55
90
120
230
350
530
20QI
90
100
200
270
520
600
Filter size, port size
GMF 21 - G1”
GMF 22 - G1”
GMF 31 - G1½”
GMF 32 - G1½”
GMF 41 - G2”
GMF 42 - G2”
Nominal flow (l/min) for filter assembly at viscosity 30cSt
Please note the bolded options reflect standard options with a reduced lead-time
of (4) weeks or less. Consult Parker Filtration on all other lead-time options.
Average filtration beta ratio ß (ISO 16889) / particle size µm [c]
% efficiency, based on the above beta ratio (ßx)
ßx(c)=2
50.0%
N/A
N/A
N/A
6
Degree of filtration
ßx(c)=10
90.0%
N/A
N/A
6
11
ßx(c)=75
98.7%
N/A
4.5
8.5
17
ßx(c)=100
99.0%
N/A
5
9
18
ßx(c)=200
99.5%
N/A
6
10
20
ßx(c)=1000
99.9%
4.5
7
12
22
02QI
05QI
10QI
20QI
GMF iprotect
®
Series
Medium Pressure Filters
Code
V
B
Seal material
Fluoroelastomer
Nitrile
Seal type
Box 4Box 3
Quantumfiber™ filter media
iprotect® QI (20 bar collapse rating)
10QI05QI02QI
Glass fibre
Media code
Degree of filtration
20QI
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK
Bypass valve
1.7 bar
3.5 bar
6.0 bar
Bypass valve
Indicator
1.2 bar
2.5 bar
5.0 bar
Code
G
K
M
Box 6
Code
M3
T1
P
F1
F2
F3
F4
Visual indicator
Electrical indicator
Plugged
Electronic 4 LED, PNP, N.O.
Electronic 4 LED, NPN, N.O.
Electronic 4 LED, PNP, N.C.
Electronic 4 LED, NPN, N.C.
Indicator
Box 5
Code
1
4
EX
Options
Standard
Bowl with drain port
ATEX certified*
(Category 2, non-electrical equipment)
Options
Box 8
When filter includes a bypass valve but not an indicator,
code denotes bypass setting.
Note 1*: For ATEX classified filters add EX after the code.
ATEX certified filters with electrical indicator are available on request.
Visual indicators are classified as Category 2, non electrical equipment.
Filter assemblies with EX code will be supplied with a dedicated name plate.
Pls consult Parker Filtration for any questions related to the classification of our products.
Code
G12
G16
G20
G24
G24
G32
R32
Ports
GMF size 2: Thread G
3
/4
Thread G1
GMF size 3: Thread G1
1
/4
Thread G1
1
/2
GMF size 4: Thread G1
1
/2
Thread G2
SAE flange 2" 3000-M
Filter connection
Box 7
Order code Filter size and seal type
930000140 GMF21 & GMF22 Seal Kit Nitrile
930000141 GMF31 & GMF32 Seal Kit Nitrile
930000142 GMF41 & GMF42 Seal Kit Nitrile
930000149 GMF21 & GMF22 Seal Kit Fluoroelastomer
930000150 GMF31 & GMF32 Seal Kit Fluoroelastomer
930000151 GMF41 & GMF42 Seal Kit Fluoroelastomer
GMF Seal Kits
7
Ordering Information
GMF spare elements
Note: Filter assemblies ordered from the product configurator on previous page are on extended lead times. Where possible, please make your selection from the table above.
Selecting the M3 or T1 type indicator will not extend the lead time for the standard products.
Part numbers
GMF2205QIVPKG161
GMF2210QIVPKG161
GMF2220QIVPKG161
GMF3205QIVPKG241
GMF3210QIVPKG241
GMF3220QIVPKG241
GMF4205QIVPKG321
GMF4210QIVPKG321
GMF4220QIVPKG321
Fluoroelastomer seals
Element type
GMF 21 Glassfibre 2 µm
GMF 21 Glassfibre 5 µm
GMF 21 Glassfibre 10 µm
GMF 21 Glassfibre 20 µm
GMF 22 Glassfibre 2 µm
GMF 22 Glassfibre 5 µm
GMF 22 Glassfibre 10 µm
GMF 22 Glassfibre 20 µm
GMF 31 Glassfibre 2 µm
GMF 31 Glassfibre 5 µm
GMF 31 Glassfibre 10 µm
GMF 31 Glassfibre 20 µm
GMF 32 Glassfibre 2 µm
GMF 32 Glassfibre 5 µm
GMF 32 Glassfibre 10 µm
GMF 32 Glassfibre 20 µm
GMF 41 Glassfibre 2 µm
GMF 41 Glassfibre 5 µm
GMF 41 Glassfibre 10 µm
GMF 41 Glassfibre 20 µm
GMF 42 Glassfibre 2 µm
GMF 42 Glassfibre 5 µm
GMF 42 Glassfibre 10 µm
GMF 42 Glassfibre 20 µm
Flow
(l/min)
60
80
100
200
280
320
490
530
600
Model
number
GMF size 2
GMF size 2
GMF size 2
GMF size 3
GMF size 3
GMF size 3
GMF size 4
GMF size 4
GMF size 4
Element
length
2
2
2
2
2
2
2
2
2
Media
rating (µ)
5
10
20
5
10
20
5
10
20
Seals
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
Fluorelastomer
iprotect
®
QI
Order code
938895Q
938896Q
938897Q
938898Q
938899Q
938900Q
938901Q
938902Q
938903Q
938904Q
938905Q
938906Q
938907Q
938908Q
938909Q
938910Q
938911Q
938912Q
938913Q
938914Q
938915Q
938916Q
938917Q
938918Q
Indicator
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Plugged indicator port
Collapse pressure 20 bar
Description
GMF 21 02QI V Element
GMF 21 05QI V Element
GMF 21 10QI V Element
GMF 21 20QI V Element
GMF 22 02QI V Element
GMF 22 05QI V Element
GMF 22 10QI V Element
GMF 22 20QI V Element
GMF 31 02QI V Element
GMF 31 05QI V Element
GMF 31 10QI V Element
GMF 31 20QI V Element
GMF 32 02QI V Element
GMF 32 05QI V Element
GMF 32 10QI V Element
GMF 32 20QI V Element
GMF 41 02QI V Element
GMF 41 05QI V Element
GMF 41 10QI V Element
GMF 41 20QI V Element
GMF 42 02QI V Element
GMF 42 05QI V Element
GMF 42 10QI V Element
GMF 42 20QI V Element
Bypass
settings
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
element collapse
pressure
20 bar
20 bar
20 bar
20 bar
20 bar
20 bar
20 bar
20 bar
20 bar
Replacement elements
938900Q
938901Q
938902Q
938908Q
938909Q
938910Q
938916Q
938917Q
938918Q
Ports
G1"
G1"
G1"
G1½"
G1½"
G1½"
G2"
G2"
G2"
Standard products table
Standard products table
Parker Hannifin
Hydraulic Filter Division Europe
FDHB818UK Rev.B
8