10
10-24
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Characteristics
Seat valves series D4S are designed for directional con-
trol functions. A large variety of poppets, springs and co-
vers – including shuttle valves, stroke limiters, solenoid
valves (VV01) and position control – allows to design indi-
vidual hydraulic solutions for nominal flow up to 600 l/min.
A complete program is offered under the Parker brand:
subplate mounted valves (D4S - chapter 6),
SAE flange valves (D5S - chapter 9),
pipe mounted valves (D4S - chapter 10),
slip-in cartridges (CAR - on request).
Features
• Leak-free seat valve design
• 2 body designs
- L-body (2-port)
- T-body (3-port)
• Numerous pilot options
• 4 port sizes
- G ½", G 1" for T-body
- G ¾", G 1 ¼" for L-body
• 6 poppet types
D4S10 L-body
D4S06 L-body
10
10-25
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Ordering Code
Code Options
omit Standard
013
Cover for
position control
Code Port size
03
NG10
(CAR4 build-in)
06
NG25
(CAR2 build-in)
10
NG32
(CAR2 build-in)
Seat
valve
Spool
type
Nominal
size
Code Body Ports
6
D4S03 T-body
D4S06 T-body
A, B = G½"; X, Y1 = G¼"
A, B = G1"; X, Y1 = G¼"
D
D4S06 L-body
D4S10 L-body
A, B = G¾"; X, Y1 = G¼"
A, B = G1¼"; X, Y1 = G¼"
1)
Springs 2, 3 and 6 only.
2)
Position control for D4S06/10 only. Spring 2 or 4.
Spool A and sleeve 3. Valve open: proximity switch damped.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
Body
Code Sleeve
1 AA = 95 %, AB = 5 %
3 AA = 60 %, AB = 40 %
Design
series
Seals
Code Pilot oil line in body
A-X B-Y
1
internal from A
2
external from X
Code Ports X Y Z X-Y Y1
VV01
Standard
1 Pilot oil = pilot drain —
C Pilot oil = pilot drain —
With solenoid valve (VV01)
2 Ext. PD from cap
6 Internal pilot drain
With stroke limiter (not for D4S03)
3 Pilot oil = pilot drain — — — —
4 Pilot oil = pilot drain — — — —
Sleeve
Switching
type
Solenoid
voltage
Code Switching type
omit
Standard
w/o vent function
09 VV01 with manual override
de-energized: open
10 VV01 without manual override
11 VV01 with manual override
de-energized:
closed
12 VV01 without manual override
CA Shuttle valve
DA Shuttle valve
CB VV01 code 09 and shuttle valve code CA
CD VV01 code 11 and shuttle valve code CA
DB VV01 code 09 and shuttle valve code DA
DD VV01 code 11 and shuttle valve code DA
BH
VV01 code 10 and shuttle valve code CA and
position control
2)
with amplifier
BK
VV01 code 12 and shuttle valve code CA and
position control
2)
with amplifier
BN
VV01 code 10 and shuttle valve code DA and
position control
2)
with amplifier
BQ
VV01 code 12 and shuttle valve code DA and
position control
2)
with amplifier
BC VV01 code 10 and position control
2)
with amplifier
BE VV01 code 12 and position control
2)
with amplifier
BA Position control
2)
with amplifier
BF
Position control
2)
with amplifier and
shuttle valve code CA
BL
Position control
2)
with amplifier and
shuttle valve code DA
Cap
version
Pilot
connection
Code Size Poppet type Sleeve
1
03, 06,10
With closed bottom and 15° chamfer
(pZ max. = pA +20 bar
1
2
03
With 0.8 dia. orifice at the bottom and
15° chamfer
1
06, 10
With 1.2 dia. orifice at the bottom and
15° chamfer
1
4
03, 06,10
With closed bottom and 45° chamfer 1, 3
A
1)
06, 10
Safety spool (for position control only) 3
B
1)
06, 10
Throttle spool, 10° chamfer 3
C
1)
06, 10
Throttle spool, 3° chamfer
3
open bore closed bore orifice Ø 1.2
Code Seals
1 NBR
5 FPM
OptionsSpring
Code
Spring (approx. cracking pressure [bar])
Sleeve Code 1 Sleeve Code 3
A -> B A -> B B -> A
D4S03 D4S06/10 D4S03 D4S06/10 D4S03 D4S06/10
1 2.8 3.5 6.5 6.5 9.5 11.0
2 0.5 0.5 1.0 1.0 1.5 1.7
3 0.3 0.3 0.6 0.6 0.9 1.0
4 2.2 2.2 4.0 3.5 5.5 6.0
5 — 9.0 — 16.0 — 28.0
6 1.2 1.2 2.0 2.2 3.0 3.8
7 3.0 — 8.0 — 12.0 —
Code Solenoid voltage
omit Standard w/o vent function
G0R 12 V=
G0Q 24 V=
GAR
3)
98 V=
GAG
3)
205 V=
W30 110 V / 50 Hz; 120 V / 60 Hz
W31 230 V / 50 Hz; 240 V / 60 Hz
Examples see end of chapter
D4S
B
10
10-26
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
G0R G0Q GAR GAG W30 W31
12 V = 24 V = 98 V = 205 V =
110 at 50 Hz
120 at 60 Hz
230 at 50 Hz
240 at 60 Hz
±10 ±10 ±10 ±10 ±5 ±5
2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
32.7 31 31.9 28.2 70/70 VA 70/70 VA
32.7 31 31.9 28.2 280/290 VA 280/290 VA
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
Supply voltage
[V]
[V]
Tolerance supply voltage [%]
Current consumption hold [A]
in rush [A]
Power consumption hold [W]
in rush [W]
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm
2
] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
General
Design
T-body L-body
Size
03 (½") 06 (1") 06 (¾") 10 (1¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight D4S T-body [kg] 3.2 6.6 — —
D4S L-body [kg] — — 3.3 5.6
Hydraulic
Max. operating pressure [bar] Ports A, B up to 350; Port Y 140 (with VV01)
Nominal flow [l/min] 180 360 360 600
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted
recommended
[cSt]/[mm
2
/s]
[cSt]/[mm
2
/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Technical Data
Technical data
D4S pilot configuration
L-body (2-port) T-body (3-port)
Standard
A-X
B
XZ Y
Y1
X-Y
ABAA
AZ
X
A
A-X
B
XZ Y
Y1
X-Y
ABAA
AZ
AA
X1
with vent valve VV01
A-X
B
ABAA
AZ
X
A
XZ Y
Y1
X-Y
VV01
A-X
B
ABAA
AZ
AA
X1
XZ Y
Y1
X-Y
VV01
10
10-27
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Characteristic Curves
Dp/Q performance curves
Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C
1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.67 1 : 1.67 1 : 1.67
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
15° chamfer 15° chamfer 45° chamfer 45° chamfer 45° chamfer 45° chamfer
orifice safety spool throttle spool
Selection of cartridges
All characteristic curves measured with HLP46 at 50 °C.
10
10-28
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
D4S 03/06 T-body D4S 06/10 L-body
Dimensions
Ports Function
Port size
D4S03 T-body D4S06 L-body D4S06 T-body D4S10 L-body
A inlet or outlet G½" G¾" G1" G1¼"
B outlet or inlet G½" G¾" G1" G1¼"
X1 external pilot port G¼"
Y1 external drain
1)
G¼"
Size L1 L2 B1 H1 H2 H3 H4
03 (T-body) 53 92 85 27.5 21 59.5 97.5
06 (T-body) 66.5 117.5 136 38 28 93 131
1)
With VV01 only
Size L3 B2 B3 B4 H5 H6 H7 H8
06 (L-body) 49 81 76 43 23 51 81 119
10 (L-body) 49.8 120.7 85.6 77.8 38.1 50.8 96 134
Seal kits
NG NBR FPM
03 S26-58507-0 S26-58507-5
06 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
10
10-29
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
D4S with VV01
Dimensions
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5
10
10-30
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
External drain out of the cap
DC = 165.6 / AC = 153
90.5
60
133 with VV01
86 without VV01
47
70
Vent valve
VV01
Position
control
Cap
Body D4S
150
Cover
Code
013
Cable 2 m lg.
Position control by proximity switch (incl. amplifier)
Valve open: proximity switch activated.
This proximity switch is pressure proof and has no wea-
ring parts.
Note
Position control for D4S06 and D4S10 only.
D4S position control
Dimensions
D4S stroke limiter
Function PNP, contact
Supply voltage (Us) [VDC] 10...30
Supply voltage ripple [%] £ 10
Current consumption [mA] max. 8
Residual voltage L-signal [V] Us - 2.2 at l
max
Output current (I) [mA] £ 200
Protection class IP67
Ambient temperature [C°] -25...+70
Wire cross section [mm
2
] 3 x 0.5
Note:
Stroke limiter not for use with D4S03, VV01, shuttle valve and positon control.
10
10-31
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Ordering Code Explanation (Examples)
D4S direct operated
D4S with solenoid valve VV01
10
10-32
Directional Seat Valve
Series D4S
D4S UK.indd CM 03.03.17
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Ordering Code Explanation (Examples)
D4S with position control
D4S with stroke limiter