BC31
Cavity PlugsTechnical Information
Catalog MSG17-3502/UK
Parker Hannifin Corporation
Mobile Hydraulic Systems Division Europe
Check
Valves
CV
Shuttle
Valves
SH
Load/Motor
Controls
LM
Flow
Controls
FC
Pressure
Controls
PC
Logic
Elements
LE
Directional
Controls
DC
Solenoid
Valves
SV
Proportional
Valves
PV
Coils &
Electronics
CE
Bodies &
Cavities
BC
Technical
Data
TD
Omit C C C C C C C C C
A O O C O O O C
B O C O O O C O
C C O O O C O O
D *O *O *C *C
E C O O C
Ordering Information
Plug Cavity Plug
Thread Size
Cavity
Type
Type Seals
Code Seals
Omit Nitrile
Code Cavity Plug Thread Size
08 3/4 - 16
10 7/8 - 14
12 1-1/16 - 12
16 1-5/16 - 12
Consult Factory for Shaded Areas.
SymbolsGeneral Description
Parker cavity plugs can be used in any Integrated
Hydraulic Circuit where one valve serves several
machines and/or options. Two machines may have
identical circuits except for one having a pressure
reducing function, and the other not having this
function. The machine that does not require this
function can have the pressure reducing function
replaced by a cavity plug; thereby utilizing a common
body for both machines.
Specifications
Maximum Working Pressure - 350 Bar (5000 PSI)
Material - Steel
P
Code Cavity Type
2 Two Way
3 Three Way
4 Four Way
4C Four Way Special
Two Way Three Way Four Way
Code 1 2 1 2 3 1 2 3 4
C = Blocked O = Open
* Only Available In Sizes 08 and 10.
Consult Factory for Shaded Areas.
(3
)
(3)(2)
(4
)
(4)
(2
)
(2)
(3)
(2)
(1)(1)
(1)
(1)
2-Way
PXX-2
3-Way
PXX-3
4-Way
PXX-4
4-Way Special
PXX-4C
2-Wa
y3
-Way
4-Way
4-Way
Special
1
3
4
2
Type
N