Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2-Way High-Response Valve
Series TDP
TDP UK.INDD CM 14.09.15
8-115
General
Design
Proportional throttle valve, slip-in cartridge according to ISO 7368 (except for size NG125)
Nominal size DIN
NG25 NG32 NG40 NG50 NG63 NG80 NG100 NG125
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTF
D
value
1)
[years] 75
Weight [kg] 11 13 15 26 52 105 157 193
Vibration resistance [g] 10 sinus 5...2000 Hz acc. IEC 68-2-6
30 random noise 20...2000 Hz acc. IEC 68-2-36
15 shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports A, B, X and SP up to 350, XX observe accumulator pressure rating;
port Y: max. 35
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+60 (NBR: -25...+60)
Viscosity recommended
permitted
[cSt] / [mm²/s]
[cSt] / [mm²/s]
30 ... 80
20 ... 400
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar (linear) [l/min] 420 850 1500 1900 3600 4500 8000 11500
Recommended max. flow (linear) [l/min] 800 2000 3000 4500 8000 13000 20000 29000
Nominal flow at ∆p = 5 bar (progressive) [l/min] 380 750 1300 1700 3200 3900 6800 9200
Recommended max. flow (progressive) [l/min] 700 1750 2600 4000 7000 11250 17000 23000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Pilot oil supply
external via X
external via Y
drain
Leakage in pilot valve at 100 bar [ml/min] <400
Pilot valve size NG06 NG10
Max. pilot flow at 140 bar pilot pr. [l/min] 23 30 40 40 70 80 100 100
Static/dynamic
(for optimal dynamics see installation recommendation)
Step response at pilot press. >140 bar [ms] 10.5 12 14 20 17 23 28 46
Frequency response at pilot press. >140 bar
Amplitude -3 dB; 10 % ±5 %
[Hz] 95 80 74 66 52 46 41 23
Phase -90°; 10 % +5 %
[Hz] 85 63 59 52 56 51 47 45
Hysteresis [%] < 0.1
Sensitivity [%] < 0.05
Temperature drift [%/K] < 0.025
Technical Data
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage / ripple [V] DC 22 ... 30, electric shut-off at < 19, ripple < 5 % eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 A medium lag
Input signal
Code B Voltage
Impedance
Code E Current
Impedance
Code S Current
Impedance
[V]
[kOhm]
[mA]
[Ohm]
[mA]
[Ohm]
0...+10, ripple < 0,01 % eff., surge free
100
0...+20, ripple <0,01 % eff., surge free
< 250
4...20, ripple <0,01 % eff., surge free
<3,6 mA = disable, , >3,8 mA = enble on according to NAMUR NE43
< 250
Differential input max. [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Enable signal [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] 0...+10 / +12.5 error detection, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply
is to be switched off by a suitable switching element with sufficient reliability.