Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-55
3-Port Compensator
Series R5P
R5P UK.INDD CM 02.08.11
Characteristics
Direct operated 3 way pressure compensators series R5P
can be combined with any type of fixed or adjustable flow
resistor (throttle) to provide a load compensated flow.
The combination with the proportional throttle valve F5C
serves as a compact 3 way flow control unit in SAE flange
design. The R5P is typically used as meter-in compensa-
tor in front of the flow resistor.
The R5P is additionally equipped with a pressure relief
pilot, that controls the compensator cartridge and oper-
ates a system pressure relief valve. The R5P*P2 provides
a proportional relief function.
Features
• Seated type 3 way pressure compensator
• SAE61 flange
• 8.4 bar control pressure
• Pressure relief function (optionally proportional)
• With optional vent function
• 3 sizes, SAE 3/4“, 1“, 1 1/4“
• Load compensated flow in combination with F5C
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-56
R5P UK.INDD CM 02.08.11
3-Port Compensator
Series R5P
AR5P
SAE 61
Interface
Pressure
stages
3-port
compensator
Design
series
Seals OptionsPilot
connection
Nominal
size
Pilot
ports
Adjust-
ment
Switching
type
Solenoid
voltage
Code Adjustment
1 Hand knob
3
Acorn nut with
lead seal
Code Switching type
omit
Standard w/o
vent function
09
Solenoid not activated
unpressure circulation
11
Solenoid activated
unpressure circulation
Ordering Code
Code Seals
6)
1 NBR
5 FPM
6)
Further seals on request
3)
Through port Y1.1
4)
PP through port X1 in outlet flange
Code Pilot connection
2
internal PD
internal PP
4)
6
external PD
3)
internal PP
4)
Code Solenoid voltage
omit
Standard w/o
vent function
G0R 12V=
G0Q 24V=
GAR
5)
98V=
GAG
5)
205V=
W30
110V / 50Hz
120V / 60Hz
W31
230V / 50Hz
240V / 60Hz
Code Port size
06 SAE ¾"
08 SAE 1"
10 SAE 1¼"
1)
Y1 port is used in combination with
F5C, when the F5C should be drained
through the R5P (internal or external
drain)
Code Pilot ports Port Y1
1)
9
G¼"
plugged
P open
SAE 61 interface
Code Size
Max. pressure
[bar]
4 10 280
5 06/08 350
Code Pressure stages
1 7...105 bar
3 7...210 bar
5
2)
7...350 bar
2)
R5P10-4*5 up to 280 bar
5)
To be used in combination with
rectifier plugs at 120VAC/230VAC
power supply.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-57
3-Port Compensator
Series R5P
R5P UK.INDD CM 02.08.11
Code Seals
5)
1 NBR
5 FPM
Ordering Code
AR5P
Design
series
Seals Options
P2
Propor-
tional
pressure
control
G0R
Solenoid
voltage
12V 2.3A
SAE 61
Interface
Pressure
stages
3-port
compensator
Pilot
connection
Nominal
size
Pilot
ports
Adjust-
ment
Code Adjustment
1 Hand knob
3
Acorn nut with
lead seal
5)
Further seals on request
3)
Through port Y1.1
4)
PP through port X1 in outlet flange
Code Pilot connection
2
internal PD
internal PP
4)
6
external PD
3)
internal PP
4)
Code Port size
06 SAE ¾"
08 SAE 1"
10 SAE 1¼"
1)
Y1 port is used in combination with
F5C, when the F5C should be drained
through the R5P (internal or external
drain)
Code Pilot ports Port Y1
1)
9
G¼"
plugged
P open
SAE 61 interface
Code Size
Max. pressure
[bar]
4 10 280
5 06/08 350
Code Pressure stages
1 7...105 bar
3 7...210 bar
5
2)
7...350 bar
2)
R5P10-4*5 up to 280 bar
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-58
R5P UK.INDD CM 02.08.11
3-Port Compensator
Series R5P
G0R G0Q GAR GAG W30 W31
12V = 24V = 98V = 205V =
110 at 50Hz
120 at 60Hz
230 at 50Hz
240 at 60Hz
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
31 31 31 31 78 78
31 31 31 31 264 264
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTF
D
value [years] 150
Weight R5P [kg] 3.7 4.4 5.3
R5P with VV01 [kg] 5.4 6.1 7.0
Hydraulic
Max. operating pressure [bar]
Ports A, B 350 350 280
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [°C] -20...+80
Viscosity permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Electrical (solenoid) R5P with VV01
Duty ratio [%] 100
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
Supply voltage
[V]
Tolerance supply voltage [%]
Power consumption hold
in rush
[W]
Response time [ms] Energized / De-energized AC: 20/18 , DC: 46/27
Max. switching frequency AC: up to 7200, DC: up to 16000 switchings/hour
Coil insulation class H (180 °C)
Technical Data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTF
D
value [years] 75
Weight [kg] 5.5 6.2 7.1
Hydraulic
Max. operating pressure Ports A, B [bar] 350 350 280
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 90 300 600
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [°C] -20...+80
Viscosity permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Electrical (proportional solenoid)
Duty ratio [%] 100
Nominal voltage [V] 12
Max. current [A] 2.3
Coil resistance [Ohm] 4 at 20°C
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Power amplifier PCD00A-400
R5P
R5P*P2
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-59
3-Port Compensator
Series R5P
R5P UK.INDD CM 02.08.11
Dimensions
R5P
l1 l2 l3 l4 l5 l6 b1 b2 h1 h2 h3 h4 h5 h6 d1 d2 d3
R5P06 47.6 63 56 148 1 49 60 20 119 81.6 29.5 22.2 41.6 20.8 19 10.5 3/8" UNC
R5P08 52.4 65 58 144.6 5 54.5 60 23 142 103 30.5 26.2 48.6 24.3 25 10.5 3/8" UNC
R5P10 58.7 61 62 146.6 3 56.5 75 22 149 111.5 37.5 30.2 64.1 29.3 32 12.5 7/16" UNC
Ports
Port Function
Port size
R5P06 R5P08 R5P10
A Inlet/outlet ¾" 1" 1¼"
B2 Tank ¾" 1" 1¼"
X2 Internal pilot pressure M3
X2.2 External pilot pressure G¼"
Y1 Internal pilot drain M3
Y1.1 External pilot drain G¼"
M Pressure gauge G¼"
Seal kits
NG NBR FPM
06 S16-91461-0 S16-91461-5
08 S16-91460-0 S16-91460-5
10 S16-91459-0 S16-91459-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-60
R5P UK.INDD CM 02.08.11
3-Port Compensator
Series R5P
R5P*P2
Dimensions
Drain line only external from the pilot head (Y1.1).
The pilot drain port must be connected to a stable
low pressure tank line. Pressure variations in the
drain port should be avoided.
Space for plug removal
Note
On initial start up and after long shut down
periods bleed air from this plug.
NBR FPM
Prop. section
P2
S26-58473-0 S26-58473-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-61
3-Port Compensator
Series R5P
R5P UK.INDD CM 02.08.11
R5P with vent function
Dimensions
Code Internal drain External drain
11
B
A A
X
Z
X Y
A
B Y
A
X
Z
X Y
09
A
B
A
X
Z
X Y
A
B Y
A
X
Z
X Y
Seal kits
NBR FPM
DC solenoid
S26-58515-0 S26-58515-5
AC solenoid
S26-35237-0 S26-35237-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-62
R5P UK.INDD CM 02.08.11
Notes