Tanktop Mounted Return Line Filters
TTF Series
MAX 500 I/min - 10 bar
Low pressure filters
®
LEIF
LEIF
®
AN INNOVATIVE GREEN
FILTER FEATURING
11
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Tanktop Mounted Return Line Filters
TTF Series
Typical Applications
Waste management trucks
Mobile cranes
Power packs
Wheeled loaders
Drilling equipment
Features & Benefits
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 2
12
Features
10 bar rated filter
Cast aluminium head
LEIF
®
elements
Magnetic pre-filtration
In-to-Out filtration
High level of customisation
Full flow bypass with low hysteresis
Standard or customised funnel
Advantages
Can be utilised for severe return line applications
Compact profile, lightweight and durable
Patented element safeguards the use of
genuine parts
Removes ferrous particles, even during bypass
conditions
All captured contamination retains inside the
element
Dedicated system-matched solutions can be
easily made available
Reduction of bypass period due to low hysteresis
Only a small part of the total flow is bypassing
the element
Ensures that oil enters the tank under the oil level
Benefits
Reduced downtime due to premature
filter failures
Less weight, smaller envelop and
cleaner appearance
Guaranteed quality of filtration
Contributes to ISO 14001 certification
Improved fluid cleanliness levels
Extended element life time
No recontamination of system during
change of elements
Improved integration of filter in system
combined with lower initial system costs
Improved protection of system
Significant reduction of oil foaming
The Parker Filtration TTF Series
Return Line Filters
TTF tank top mounted return line filters feature pre-filtration by means
of a magnet column and a full flow bypass with low hysteresis.
Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak
back into the system. TTF filters are available in versions capable
of handling flow rates up to 500 l/min. They can operate up to a
maximum working pressure of 10 bar. Optional filling port in filter
cover, second return port and customised diffusers can be specified.
Manifold type filter head (TSR Series) with four return ports is also
available.
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Low pressure filters
Specification
Operation pressure:
Max. 10 bar.
Assembly:
Tank top mounted.
Connections:
Threaded BSP ports.
Flanged ports on request.
Manifold filter head type TSR on request
available for flows up to 250 l/min.
Filter housing:
Aluminium head and cover.
Seal material:
Nitrile, fluoroelastomer, neoprene.
Operation temperature range:
-40 to +120°C.
Bypass setting
Opening pressure 0.8 / 1.5 or 2 bar.
Other settings on request.
Degree of filtration:
Determined by multipass test according to
ISO 16889.
Flow fatigue characteristics:
Filter media is supported so that the
optimum fatigue life is achieved.
Filtration media:
Microglass III and Ecoglass III for LEIF
®
elements.
Also available 10μm cellulose and 40μm stainless steel mesh.
Element collapse rating:
10 bar (ISO 2941)
Pressure indicator options:
Setting 0.7 or 1.2 bar.
Other settings on request.
Visual pressure gauge.
Electrical pressure switch.
Options:
Diffuser type P (straight pipe, no perforated plate area)
Diffuser type T (with closed diffuser end cap and with perforated plate
area, recommended when oil entry in reservoir is close to the reservoir
bottom or to ensure oil entry under the reservoir oil level)
Magnetic pack:
Standard. TTF400 and 500 are standard supplied without magnets
Filling port in cover: (optional)
Plugged.
Filter element:
LEIF
®
element with reusable metal element sleeve.
Optional conventional style element with steel end caps.
The LEIF
®
element is patented and safeguards the use of genuine parts.
Note: LEIF
®
element can be used with mineral and HEES type oils.
For other fluids consult Parker Filtration.
LEIF
®
contributes to ISO 14001 quality standards.
13
Type
Standard length TSR2
185
271
404
201
286
421
150
286
369
TSR 120
TSR 200
TSR 250
HFL
G1 (BSP)
SAE16
G1
1
/4 (BSP)
SAE20
Ports A Ports B
Note: All ports for return flow only
Max nominal return flow 120-200-250 l/min
Max working pressure 10 bar
Temperature range -30°C to +100°C
Bypass pressure 1,5 bar
LEIF
®
-filtration ratio 2μ/5μ/10μ/20μ
Seals NBR
Options Dipstick
Indicator (electrical/visual)
Technical specification
Ref. No. Description
1 4 Flange nut
31Cover
4 1 Cover-seal
5 1 Top-spring
6 1 Insert
7 1 Insert-seal
8 1 Element
9a 0-1 Indicator
9b 0-3 Plug M10x1
10 0-3 Unit-ring
11 1 Housing
12 1 Gasket
13 1 Sleeve
14 1 Funnel/diffuser
15 1 O-ring
16 1 Bypass set
TTF sealkit: No. 4+7+12
TTF TSR
1
3
4
5
6
7
8
10
11
12
13
14
15
16
9a
9b
Type 1-125/2-170/2-230/2-300
2-400 / 2-500
Type 1-60/1-90/1-120
Free element clearance
F
81
36
Min. oil level
Mounting hole
B
137
L
H
Ø
50
Ø
102±1
Ø
41
0.3
3.2
B
AA
Ø
165 pitch
64
81
81
4x ISO228
G
1
/8” (BSP)
4x
Ø
11
12
Dimensions in mm
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Tanktop Mounted Return Line Filters
TTF Series
Specification (cont.)
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 2
14
NOTE: TTF2 length 9 and 10 are
standard supplied without magnets
NOTE: TTF2 length 9 and 10 are
standard supplied without magnets
Type
G
3
/
4
,G1
G1, G1
1
/4,G1
1
/2
(G2 Single Port)
(Dual Port)
(1
1
/2 SAE)
28
36
(46)
73
92
(107)
68
90
(96)
60
83
10
12
4x9
4x11
G
1
/2
G
3
/4
(G1)
63
87.5
90
132
93
136
TTF60
TTF90
TTF120
TTF125
TTF170
TTF230
TTF300
TTF400
TTF500
TTF length
2
3
4
5
6
7
8
9
10
Connection Option
hh1
D
D1 H1 b R R1 R2 K FP
131
175
225
325
223
303
508
523
563
Section A-A
Section A-A
Top view
H1
h1
h
d
Ø
D1
96
b
A
A
R
K
R1
Ø
D
H1
h1
h
d
Ø
D1
Torqueload filter-cover
For TTF up to length 5 - 4 Nm max.
For TTF length 6 and larger - 10 Nm max.
Optional for TTF2 series
1
1
/2” SAE-3000PSI
or G2”
FP
(Optional plugged
filling port)
Torqueload filter-tank
For TTF up to length 5 - 15 Nm max.
For TTF length 6 and larger - 40 Nm max.
R
2
5
*
Top view
96
b
A
A
R
K
Torqueload filter-cover
For TTF up to length 5 - 4 Nm max.
For TTF length 6 and larger - 10 Nm max.
Optional for TTF2 series
1
1
/2” SAE-3000PSI
or G2”
FP
(Optional plugged
filling port)
Torqueload filter-tank
For TTF up to length 5 - 15 Nm max.
For TTF length 6 and larger - 40 Nm max.
R2
5*
Dimensions in mm
R1
Ø
D
H2
100
For TTF length 5 and larger For TTF length 2, 3 and 4
Type
G
3
/
4
,G1
G1, G1
1
/4,G1
1
/2
(G2 Single Port)
(Dual Port)
(1
1
/2 SAE)
28
36
(46)
73
92
(107)
68
90
(96)
60
83
10
12
4x9
4x11
G
1
/2
G
3
/4
(G1)
63
87.5
90
132
93
136
TTF60
TTF90
TTF120
TTF125
TTF170
TTF230
TTF300
TTF400
TTF500
TTF length
2
3
4
5
6
7
8
9
10
Connection Option
hh1
D
D1 H1 H2 b R R1 R2 K FP
235
280
330
420
305
305
510
525
575
Dimensions in mm
Without Funnel
With Funnel
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
0
0.05
0.1
0.2
0.25
0.3
0.15
0.35
0 50 100 150 200 250
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Flow (US GPM)
6653
013 3926
Δp (PSID)
0
0.73
2.90
3.63
5.08
4.35
1.45
2.18
TSR250 (Element length code 3)
0
0.1
0.2
0.4
0.5
0.6
0.7
0.3
0.8
0 20406080100120
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Flow (US GPM)
21160 5 11 26
31
Δp (PSID)
0
1.5
2.9
4.4
5.8
7.3
8.7
10.2
11.6
TSR120 (Element length code 1)
0
0.05
0.1
0.2
0.25
0.3
0.15
0.35
0 50 100 150 200 250
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Flow (US GPM)
6653
013 3926
Δp (PSID)
0
0.73
2.90
3.63
5.08
4.35
1.45
2.18
TSR (Element length code 2)
0
0.5
1
2
1.5
0 20406080100
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Δp (PSID)
0
7.3
14.5
21.8
29
Flow (US GPM)
0 5 11 16 21 26
TTF60 (Element length code 2)
0 306090120150
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Δp (PSID)
Flow (US GPM)
3931
08 2416
0
0.2
0.4
0.8
1
0.6
1.4
1.2
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
TTF90 (Element length code 3)
0
0.2
0.4
0.8
1
0.6
1.4
1.2
0 60 120 180
02Q
05Q
20Q
Flow (l/min)
Δp (bar)
10Q
Δp (PSID)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
47
016 31
TTF125 (Element length code 5)
0 30 60 90 120 150 180
02Q
05Q
10Q
20Q
Flow (l/min)
Δp (bar)
Δp (PSID)
Flow (US GPM)
31240 8 16 39
47
0
0.2
0.4
0.8
1
0.6
1.4
1.2
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
TTF120 (Element length code 4)
Low pressure filters
Pressure Drop Curves
15
The recommended level of the initial pressure drop for low pressure filters is max 0.5 bar.
If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows:
p=(p32 x viscosity of medium used) / 32cSt.
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Tanktop Mounted Return Line Filters
TTF Series
Pressure Drop Curves (cont.)
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 2
16
050
100 150 200 250 300 350 400 450
Flow (l/min)
Δp (bar)
02Q
05Q
10Q
20Q
Flow (US GPM)
530 132639 667992106
119
0
0.7
0.5
0.4
0.3
0.2
0.1
0.6
0.8
0.9
1
Δp (PSID)
0
1.5
4.4
2.9
5.8
7.3
8.7
10.2
14.5
13.1
11.6
0
050
1.2
0.8
0.6
0.4
0.2
1
1.4
1.6
100 150 200 250 300 350 400 450 500
Flow (l/min)
Δp (bar)
02Q
05Q
10Q
20Q
Δp (PSID)
0
2.9
5.8
8.7
11.6
14.5
17.4
23.2
20.3
Flow (US GPM)
53 66 92 106 119
132
392613079
TTF230 (Element length code 7)
TTF300 (Element length code 8)
0
1.2
0.8
0.6
0.4
0.2
1
1.4
1.6
1.8
0 50 100 150 200 250 300 350 400 450 500 550
Flow (l/min)
Δp (bar)
02Q
05Q
10Q
20Q
Δp (PSID)
0
2.9
5.8
8.7
11.6
14.5
17.4
26.1
23.2
20.3
Flow (US GPM)
261306653 92 106 119 14513239 79
0
050
1.2
0.8
0.6
0.4
0.2
1
1.4
1.6
100 150 200 250 300 350 400 500450 550 600
Flow (l/min)
Δp (bar)
02Q
05Q
10Q
20Q
Δp (PSID)
0
2.9
5.8
8.7
11.6
14.5
17.4
23.2
20.3
Flow (US GPM)
261306653 92 106 119 15914513239 79
TTF400 (Element length code 9)
TTF500 (Element length code 10)
0
050
2
1.5
1
0.5
2.5
100 150 200 250 300 350
Flow (l/min)
Δp (bar)
02Q
05Q
10Q
20Q
Δp (PSID)
0
7.3
14.5
21.8
29
36.3
Flow (US GPM)
0 13263953667993
TTF170 (Element length code 6)
The recommended level of the initial pressure drop for low pressure filters is max 0.5 bar.
If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows:
p=(p32 x viscosity of medium used) / 32cSt.
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Low pressure filters
17
0
015
0.08
0.12
0.06
0.04
0.02
0.1
30 45 60 75 90
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
1.74
Flow (US GPM)
0 4 8 12162024
TTF60 (Element length code 2)
Cellulose & stainless steel media
0
0
0.08
0.12
0.06
0.04
0.02
0.1
30 60 90 120
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
1.74
Flow (US GPM)
0 8 16 24 31
TTF90 (Element length code 3)
Cellulose & stainless steel media
0
0
0.08
0.14
0.12
0.06
0.04
0.02
0.1
30 60 90 210180150120
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
2.03
1.74
Flow (US GPM)
0 8 16 24 56473931
TTF120 (Element length code 4)
Cellulose & stainless steel media
0
0
0.08
0.12
0.06
0.04
0.02
0.1
30 60 90 150120
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
1.74
Flow (US GPM)
0 8 16 24 3931
TTF125 (Element length code 5)
Cellulose & stainless steel media
0
0
0.08
0.12
0.06
0.04
0.02
0.1
30 60 90 210180150120
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
1.74
Flow (US GPM)
0 8 16 24 56473931
TTF170 (Element length code 6)
Cellulose & stainless steel media
0
0
0.08
0.14
0.12
0.06
0.04
0.02
0.1
50 100 150 300250200
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
2.03
1.74
Flow (US GPM)
0 132639 796653
TTF230 (Element length code 7)
Cellulose & stainless steel media
0
0
0.08
0.14
0.12
0.06
0.04
0.02
0.1
50 100 150 400300 350250200
Flow (l/min)
Δp (bar)
10C
040W
Δp (PSID)
0
0.29
0.58
0.87
1.16
1.45
2.03
1.74
Flow (US GPM)
0 132639 10679 926653
TTF300 (Element length code 8)
Cellulose & stainless steel media
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Indicator Thread
M10
M10
M10
G1/8"
M10
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
Tanktop Mounted Return Line Filters
TTF Series
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 2
18
Ordering Information
G
1
/
8
(BSP)
Ø
28
9
Protective cover
M10x1
24 A/F
55
74
9
58
75
Elec.rating
Thread connection
Elec.connection
Protection
Code
42V/4A
M10x1
AMP 6.3x0.8 terminals + protective cap
IP65 (with cap) terminals IP00
FMUS1EBMM10L (Switch)
Specifications
Port(s) Filter head
ISO 228-G
3
/4" (BSP) (TTF length 2,3,4 and 5)
ISO 228-G1" (BSP)
ISO 228-G1
1
/4" (BSP) (TTF length 7 and larger)
2xISO 228-G1
1
/4" (BSP) (TTF length 7 and larger)
ISO 228-G1
1
/2"(BSP) (TTF length 7 and larger)
2xISO 228-G1
1
/2"(BSP) (TTF length 7 and larger)
1
1
/2" SAE-3000 PSI (TTF length 7 and larger)
1
1
/2" SAE-3000 PSI (2nd port) + G1
1
/2" (TTF length 7 and larger)
G2" (TTF length 7 and larger)
G2"+G1
1
/2" (TTF length 7 and larger)
ISO 228-G1
1
/4" (BSP) + 2 Ports A ISO228-G1" (TSR only)
2xISO 228-G1
1
/4" (BSP) + 2 Ports A ISO228-G1" (TSR only)
SAE20+2PortsASAE16(TSR only)
2xSAE20 + 2 Ports SAE16 (TSR only)
Indicator Connection / Filter Head Matrix
Elec.rating
Thread connection
Elec.connection
Protection
Switch type
Code
42V / 2A
G
1
/
8
AMP terminal 6.3x0.8
IP65 (terminal IP00)
NO or NC
FMUS2EBMG02L (NO switch)
FMUS3EBMG02L (NC switch)
Specifications
Indicator PS NO/NC pressure switch
Indicator Options
Protective cap
with dual cable duct
for 1, 7-2, 3mm diameter cable
27 A/F
Ø
30.5
M10x1
Amp 6.3x8
terminals
23
1
Switch
1 = COM.
2=N.C.
3=N.O.
Indicator PS pressure switch
Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.
Part number
TTF310QLBP2EG121
TTF320QLBP2EG121
TTF510QLBP2EG161
TTF520QLBP2EG161
TTF610QLBP2EG203
TTF620QLBP2EG203
TTF810QLBP2EG243
TTF820QLBP2EG243
TTF1010QLBP2HG24A
TTF1010QLBP2HG24A
Supersedes
TTF90-G
3
/4 TXWL3-10 B15 MM
TTF90-G
3
/4 TXWL3-20 B15 MM
TTF125-G1 TXWL3E-10 B15 MM
TTF125-G1 TXWL3E-20 B15 MM
TTF170-G1
1
/4 TXWL4-10 T B15 MM
TTF170-G1
1
/4 TXWL4-20 T B15 MM
TTF300-G1
1
/2 TXWL5A-10 T B15 MM
TTF300-G1
1
/2 TXWL5A-20 T B15 MM
TTF500-G1
1
/2
TXWL5C-10 T B20 MM NMG
TTF500-G1
1
/2
TXWL5C-20 T B20 MM NMG
Flow
(l/min)
90
90
125
125
170
170
300
300
500
500
Model
number
TTF90
TTF90
TTF125
TTF125
TTF170
TTF170
TTF300
TTF300
TTF500
TTF500
Element
length
Length 3
Length 3
Length 5
Length 5
Length 6
Length 6
Length 8
Length 8
Length 10
Length 10
Media
rating (μ)
10
20
10
20
10
20
10
20
10
20
Seals
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Indicator
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Bypass
settings
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
1.5 Bar (22 Psi)
2.0Bar(29Psi)
2.0Bar(29Psi)
Included
options
None
None
None
None
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
Replacement
elements
937878Q
937877Q
937852Q
937875Q
937853Q
937874Q
937855Q
937872Q
937857Q
937870Q
Supersedes
TXWL3-10
TXWL3-20
TXWL3E-10
TXWL3E-20
TXWL4-10
TXWL4-20
TXWL5A-10
TXWL5A-20
TXWL5C-10
TXWL5C-20
Ports
G
3
/4
G
3
/4
G1
G1
G1
1
/4
G1
1
/4
G1
1
/2
G1
1
/2
G1
1
/2
G1
1
/2
Normally open contacts
Normally closed contacts
Standard products table
Visual indicator 1.2 bar
M10: code FMUG1EBPM10L
G
1
/8: code FMUG2EBPG02L
TTF
TSR
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Low Pressure Filters
19
Ordering Information (cont.)
Code
2
3
4
5
6
7
8
9
10
1
2
3
Housing
TTF 1-60
TTF 1-90
TTF 1-120
TTF 1-125
TTF 2-170
TTF 2-230
TTF 2-300
TTF 2-400
TTF 2-500
TSR2-120
TSR2-200
TSR2-250
Filter type
Box 2
TTF
TSR
Code
Box 1
Code
B
V
N
Seal material
Nitrile
Fluorelastomer
Neoprene
Seal type
Box 4
Code
B
E
H
X
on request
Bypass valve
0.8 bar
1.5 bar
2.0 bar for TTF series
Blocked bypass
Other bypass settings
Bypass valve
Box 6
Code
G1
G2
S1
S2
S3
S4
S5
N
P
P2
on request
Pressure gauge, setting 1.2 bar, M10x1
Pressure gauge, setting 1.2 bar, G
1
/8 for dual head ports and TSR series
Pressure switch 42V, 1.2 bar setting, NO/NC, M10x1
Pressure switch 42V, 1.2 bar setting, NO with G
1
/8 BSP
Pressure switch 42V, 1.2 bar setting, NC with G
1
/8 BSP
Pressure switch 250V, NO/NC with G
1
/8
Pressure switch 220V, NO/NC with M10
No indicator, indicator ports not machined
No indicator, indicator port R plugged
No indicator, indicator ports L + R plugged
Other settings for indicators / gauges on request
Indicator
Box 5
Options
No diffuser required
Diffuser type T with perforated plate area
Diffuser type P without perforated plate area
Diffuser with integrated hose connection for TTF
lengths 2, 3 and 4
No magnets
Dipstick
Plugged filling port
Diffuser type T and no magnets
Diffuser type P and no magnets
Diffuser type T, no magnets, plugged filling port
Diffuser type P, no magnets, plugged filling port
Other combinations
Options
Box 8
Note: TTF size 2-400 and 2-500 are standard supplied
without magnets
Product configurator
Configurator example of a TTF Series filter
Box 1
TTF
Box 2
9
Box 3
05QL
Box 4
V
Box 5
S3
Box 6
H
Box 7
L24
Box 8
1
Configurator example of a TSR Series filter
Box 1
TSR
Box 2
3
Box 3
20QL
Box 4
B
Box 5
G2
Box 6
E
Box 7
2G20
Box 8
3
Note: for all dual head ports and TSR series apply G
1
/8 connection for indicator
Average filtration beta ratio ß (ISO 16889) / particle size μm [c]
% efficiency, based on the above beta ratio (ßx)
ßx(c)=2
50.0%
N/A
N/A
N/A
6
Degree of filtration
Media
code
ßx(c)=10
90.0%
N/A
N/A
6
11
ßx(c)=75
98.7%
N/A
4.5
8.5
17
ßx(c)=100
99.0%
N/A
5
9
18
ßx(c)=200
99.5%
N/A
6
10
20
ßx(c)=1000
99.9%
4.5
7
12
22
02Q/02QL
05Q/05QL
10Q/10QL
20Q/20QL
Element media
Disposable element
LEIF
®
element
Cellulose
Nom. rating
10C
20Q
20QL
Abs. rating
040W10Q
10QL
05Q
05QL
02Q
02QL
Glass fibre
Microglass III (for disposable elements)
Ecoglass III (for Leif
®
elements)
Wire mesh
Degree of filtration
Box 3
Item is standard
Item is standard green option
Item is semi standard
Item is non standard
123
123
123
123
Highlights Key (Denotes part number availability)
Note: Standard items are in stock, semi standard items are available within
four weeks
Code
G12
G16
G20
2G20
G24
2G24
L24
LD24
G32
GM32
G20
2G20
S20
2S20
Ports
ISO 228-G
3
/4" (BSP) (TTF length 2,3,4 and 5)
ISO 228-G1" (BSP)
ISO 228-G1
1
/4" (BSP) (TTF length 7 and larger)
2xISO 228-G1
1
/4" (BSP) (TTF length 7 and larger)
ISO 228-G1
1
/2" (BSP) (TTF length 7 and larger)
2xISO 228-G1
1
/2" (BSP) (TTF length 7 and larger)
1
1
/2" SAE-3000 PSI (TTF length 7 and larger)
1
1
/2" SAE-3000 PSI (2nd port) + G1
1
/2" (TTF length 7 and larger)
G2" (TTF length 7 and larger)
G2"+G1
1
/2" (TTF length 7 and larger)
ISO 228-G1
1
/4" (BSP) + 2 Ports A ISO228-G1" (TSR only)
2xISO 228-G1
1
/4" (BSP) + 2 Ports A ISO228-G1" (TSR only)
SAE20 + 2 Ports A SAE16 (TSR only)
2xSAE20 + 2 Ports SAE16 (TSR only)
Filter connection
Box 7
Code
1
3
4
9
5
6
8
A
B
C
D
on request
10023561 0-1 Hyd. Return filter-TTF310QLBG1EG123
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 2
20
Tanktop Mounted Return Line Filters
TTF Series
TTF60
Part number spare element
TTF90
Part number spare element
TTF120
Part number spare element
TTF125
Part number spare element
TTF170
Part number spare element
TTF230
Part number spare element
TTF300
Part number spare element
TXX2-10-B
937721
TXX3-10-B
937722
TXX3D-10-B
937723
TXX3E-10-B
937724
TXX4-10-B
937725
TXX5-10-B
937726
TXX5A-10-B
937727
TXW2-20-B
937790Q
TXW3-20-B
937791Q
TXW3D-20-B
937792Q
TXW3E-20-B
937793Q
TXW4-20-B
937794Q
TXW5-20-B
937795Q
TXW5A-20-B
937796Q
ST2-40-B
937820
ST3-40-B
937819
ST3D-40-B
937818
ST3E-40-B
937817
ST4-40-B
937816
ST5-40-B
937815
ST5A-40-B
937814
TXW2-10-B
937787Q
TXW3-10-B
937786Q
TXW3D-10-B
937785Q
TXW3E-10-B
937748Q
TXW4-10-B
937783Q
TXW5-10-B
937782Q
TXW5A-10-B
937781Q
TXW2-5-B
937754Q
TXW3-5-B
937755Q
TXW3D-5-B
937756Q
TXW3E-5-B
937757Q
TXW4-5-B
937758Q
TXW5-5-B
937759Q
TXW5A-5-B
937760Q
TXW2-2-B
937751Q
TXW3-2-B
937750Q
TXW3D-2-B
937749Q
TXW3E-2-B
937748Q
TXW4-2-B
937747Q
TXW5-2-B
937746Q
TXW5A-2-B
937745Q
Supersedes Spare Element table (TXW & TXX replaced by 900000 number)
TTF60
Part number spare element
TTF90
Part number spare element
TTF120
Part number spare element
TTF125
Part number spare element
TTF170
Part number spare element
TTF230
Part number spare element
TTF300
Part number spare element
TTF400
Part number spare element
TTF500
Part number spare element
TSR120
Part number spare element
TSR200
Part number spare element
TSR250
Part number spare element
TXWL2-20
937882Q
TXWL3-20
937877Q
TXWL3D-20
937876Q
TXWL3E-20
937875Q
TXWL4-20
937874Q
TXWL5-20
937873Q
TXWL5A-20
937872Q
TXWL5B-20
937871Q
TWXL5C-20
937870Q
PXWL3-20
937895Q
PXWL4-20
937896Q
PXWL4A-20
937897Q
TXWL2-10
937881Q
TXWL3-10
937878Q
TXWL3D-10
937851Q
TXWL3D-10
937852Q
TXWL4-10
937853Q
TXWL5-10
937854Q
TXWL5A-10
937855Q
TXWL5B-10
937856Q
TXWL5C-10
937857Q
PXWL3-10
937892Q
PXWL4-10
937893Q
PXWL4A-10
937894Q
TXWL2-5
937880Q
TXWL3-5
937879Q
TXWL3D-5
937825Q
TXWL3E-5
937849Q
TXWL4-5
937848Q
TXWL5-5
937847Q
TXWL5A-5
937846Q
TXWL5B-5
937845Q
TXWL5C-5
937844Q
PXWL3-5
937889Q
PXWL4-5
937890Q
PXWL4A-5
937891Q
TXWL2-2
937823Q
TXWL3-2
937824Q
TXWL3D-2
937825Q
TXWL3E-2
937826Q
TXWL4-2
937827Q
TXWL5-2
937828Q
TXWL5A-2
937829Q
TXWL5B-2
937830Q
TXWL5C-2
937831Q
PXWL3-2
937886Q
PXWL4-2
937887Q
PXWL4A-2
937888Q
Supersedes Spare Element table (TXWL & PXWL replaced by 900000 number)
Ordering Information (cont.)