208 209
Specication
Assembly:
In-line lter
Maximum operating pressure:
30 bar
Nominal ow rate (30 cSt):
230 l/min (13.8 m
3
/h)
Connections:
readed BSP ports. SAE ports available by request.
Seal material:
Nitrile, optionally Fluoroelastomer or Neoprene
Operating temperature:
-40°C...+100°C with Nitrile seals, -20°C...+120°C with
Fluoroelastomer seals. For other temperatures consult
Parker Filtration.
Housing material:
Aluminium
Weight:
See dimensions table
Bypass setting:
Opening pressure standard 1.5 bar, optionally 0.8 bar,
2.0 bar or blocked bypass
Filtration materials:
•Ecoglass for LEIF® element with reusable metal
element sleeve. LEIF® contributes to ISO14001.
•GlassbreMicroglassIII
•Resinimpregnatedcellulosepaper10μmnominal
•Cleanablemetalmesh
Magnetic pack:
Standard
Dierential pressure indicators:
Visual or Visual-electrical indicator
Setting 1.2 bar (for 2.0 bar and 1.5 bar bypass)
or 0.7 bar (for 0.8 bar bypass)
Fluid compatibility:
Suitable for use with regular hydraulic and lubrication
oils. For other uids consult Parker Filtration.
Type A B C D E F G H K L M N P S T U V Kg
BSP ISO228 SAE
GA1-30 150 106 32 G¾ 12 70 180 3 50 24 95 9 44 20 28 143 86 63 2.1
GA1-60 160 106 32 G1 16 70 235 18 50 24 95 9 54 20 29 194 86 63 2.6
GA1-90 160 106 32 G1 16 70 275 29 50 24 95 9 54 20 29 238 86 63 3.2
GA1-120 160 106 32 G1¼ 20 70 325 46 50 24 95 9 64 20 29 288 86 63 4.0
GA2-170 230 150 55 G1½ 24 105 390 35 75 37 140 12 72 25 43 338 110 88 7.9
GA2-230 230 150 55 G1½ 24 105 460 58 75 37 140 12 72 25 43 408 110 88 9.0
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA