207
GA Series
Medium Pressure Filters
Max. 230 l/min. 30 bar
Contamination-proof
and customizable
filter solution
Designedforvariousapplications.
In-outlterprinciplemeansthereis
nopossibilityforcontaminatedleak
backintothesystem.Suppliedwith
magnetic pre-filtration. Customizable
for filter coolants thus ideal for metal
cutting equipment. Visual or electronic
differential pressure indicators and
environmentallyfriendlyltration
elements available.
Applications:
• Gearboxes
• Bypassltration
• Stonecrushers
• Lubeoilsystems
• Metalcuttingequipment
Contact Information:
Parker Hannin
Hydraulic Filter Division Europe
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parker.com/hfde
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA
208 209
Specication
Assembly:
In-line lter
Maximum operating pressure:
30 bar
Nominal ow rate (30 cSt):
230 l/min (13.8 m
3
/h)
Connections:
readed BSP ports. SAE ports available by request.
Seal material:
Nitrile, optionally Fluoroelastomer or Neoprene
Operating temperature:
-40°C...+100°C with Nitrile seals, -20°C...+120°C with
Fluoroelastomer seals. For other temperatures consult
Parker Filtration.
Housing material:
Aluminium
Weight:
See dimensions table
Bypass setting:
Opening pressure standard 1.5 bar, optionally 0.8 bar,
2.0 bar or blocked bypass
Filtration materials:
•Ecoglass for LEIF® element with reusable metal
element sleeve. LEIF® contributes to ISO14001.
•GlassbreMicroglassIII
•Resinimpregnatedcellulosepaper10μmnominal
•Cleanablemetalmesh
Magnetic pack:
Standard
Dierential pressure indicators:
Visual or Visual-electrical indicator
Setting 1.2 bar (for 2.0 bar and 1.5 bar bypass)
or 0.7 bar (for 0.8 bar bypass)
Fluid compatibility:
Suitable for use with regular hydraulic and lubrication
oils. For other uids consult Parker Filtration.
Type A B C D E F G H K L M N P S T U V Kg
BSP ISO228 SAE
GA1-30 150 106 32 G¾ 12 70 180 3 50 24 95 9 44 20 28 143 86 63 2.1
GA1-60 160 106 32 G1 16 70 235 18 50 24 95 9 54 20 29 194 86 63 2.6
GA1-90 160 106 32 G1 16 70 275 29 50 24 95 9 54 20 29 238 86 63 3.2
GA1-120 160 106 32 G1¼ 20 70 325 46 50 24 95 9 64 20 29 288 86 63 4.0
GA2-170 230 150 55 G1½ 24 105 390 35 75 37 140 12 72 25 43 338 110 88 7.9
GA2-230 230 150 55 G1½ 24 105 460 58 75 37 140 12 72 25 43 408 110 88 9.0
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA
209
Visual Indicator - Manifold connected to filter housing
Code (0.7 bar setting) FMUD5BBAXXXL
Code (1.2 bar setting) FMUD5EBAXXXL
Visual / Electrical Indicator - Manifold connected to filter housing
Code (0.7 bar setting and NO type switch) FMUE5BBAXXXL
Code (1.2 bar setting and NO type switch) FMUE5EBAXXXL
Electric rating 120Vac/12VA or 100Vdc/10W
Electrical connection AMP terminal 6.3. x 0.8 with plugged cable gland
Protection IP65
Switch type NO (NC on request)
PressureDropCurvesforHousing
∆ p
total
= ∆ p
housing
+ ∆ p
element
e recommended level of the initial pressure drop for
this lter is maximum 0.5 bar.
∆ p-curves are measured at 30 cSt.
If the medium used has a viscosity dierent from 30 cSt,
pressure drop over the element can be estimated as
follows:
∆ p
total
= ∆ p
housing
+ ∆ p
element
x
working viscosity
30 cSt
GA1 housings GA2-170/230 housings
Flow [m
3
/h]
0 1 2 3 4 5 6 7 8 9
Flow [m
3
/h]
0 3 6 9 12 15 18
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA
210 211
GA Series
PressureDropCurvesforElements
GA2-230 elements (Length 7)
GA1-30 elements (Length 0)
Flow [m
3
/h]
0 1 2 3
GA1-60 elements (Length 2)
Flow [m
3
/h]
0 1 2 3 4 5 6
GA1-90 elements (Length 3)
Flow [m
3
/h]
0 3 6 9
GA1-120 elements (Length 4)
Flow [m
3
/h]
0 3 6 9 12
GA2-170 elements (Length 6)
Flow [m
3
/h]
0 3 6 9 12 15
Flow [m
3
/h]
0 3 6 9 12 15 18
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA
211
Product Description for GA
Complete Filter:
Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8
SEAL TYPE
Seal material CODE
Nitrile B
Fluoroelastomer V
Neoprene N
Table 4
BYPASS VALVE
Bypass/indicator setting CODE
0.8 bar/0.7 bar B
1.5 bar/1.2 bar E
2.0 bar/1.2 bar H
No/No X
Table 6
FILTER CONNECTIONS
Port size CODE
G¾ (length 0) G12
G1 (length 2 and 3) G16
G1¼ (length 4) G20
G1½ (length 6 and 7) G24
Table 7
GA Series
Medium Pressure Filters
FILTER TYPE
Model CODE
Medium pressure lter, aluminium GA
Table 1
FILTER SIZE
Housing size - element length CODE
1-30 0
1-60 2
1-90 3
1-120 4
2-170 6
2-230 7
Table 2
DEGREE OF FILTRATION
Element type CODE
Microglass III
Glassbre 2 µm 02Q
Glassbre 5 µm 05Q
Glassbre 10 µm 10Q
Glassbre 20 µm 20Q
LEIF
®
elements
Glassbre 2 µm 02QL
Glassbre 5 µm 05QL
Glassbre 10 µm 10QL
Glassbre 20 µm 20QL
Other medias
Cellulose 10 µm (nom) 10C
Cleanable metal mesh 40 µm 040W
Table 3
OPTIONS
Options CODE
With bypass and magnets 1
No bypass, with magnets 2
With bypass, no magnets 5
No bypass, no magnets 6
Table 8
INDICATORS
Options CODE
Visual indicator on right* D3
Visual indicator on left* D4
Visual-electrical indicator on right* E3
Visual-electrical indicator on left* E4
Both indicator ports plugged P2
Table 5
* Indicator ports on other side machined and plugged.
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA
212 213
CONVENTIONAL TYPE REPLACEMENT ELEMENTS WITH NITRILE SEALS
Element
length
Housing
size
Microglass III Cellulose
10 µm
(nom)
Cleanable
metal mesh
40 µm
02Q 05Q 10Q 20Q
0 1 - 30 937752Q 937753Q 937788Q 937789Q 937720 937821
2 1 - 60 937751Q 937754Q 937787Q 937790Q 937721 937820
3 1 - 90 937750Q 937755Q 937786Q 937791Q 937722 937819
4 1 - 120 937749Q 937756Q 937785Q 937792Q 937723 937818
6 2 - 170 937747Q 937758Q 937783Q 937794Q 937725 937816
7 2 - 230 937746Q 937759Q 937782Q 937795Q 937726 937815
LEIF
®
REPLACEMENT ELEMENTS
Element
length
Housing
size
Ecoglass III
02QL 05QL 10QL 20QL
0 1 - 30 937822Q 937885Q 937884Q 937883Q
2 1 - 60 937823Q 937880Q 937881Q 937882Q
3 1 - 90 937824Q 937879Q 937878Q 937877Q
4 1 - 120 937825Q 937850Q 937851Q 937876Q
6 2 - 170 937827Q 937848Q 937853Q 937874Q
7 2 - 230 937828Q 937847Q 937854Q 937873Q
Please note the bolded options reect standard options with reduced lead-time.
SPARE PARTS
Seal kit CODE
Seal material GA0-4 GA6-7
Nitrile 2049010009 2049010010
Fluoroelastomer 2049010031 2049010032
Neoprene 2049010038 2049010039
Parker Hannifin
HydraulicFilterDivisionEurope
FDHB500UK/GA