C10D_C.indd, ddp
131
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Slip-in Cartridge Valves
Catalog HY14-3200/US
Series C10D*CTechnical Information
General Description
Series C10D*C 2/2 way seat valves are equipped with
an inductive switch to monitor the closed position. After
the poppet is lifted from the seat, the design of the
poppet ensures that only a minimum amount of oil can
pass the seat before the inductive switch changes the
signal.
The poppet has a 60/40 area ratio (AA = 0.6 AC, AB =
0.4 Ac) and is capable for flow from A to B and B to A.
For sizes NG80 and NG100 a proximity switch 90° to
the poppet is used.
Features
•
German trade association certificate, No. 00 077.
•
Cavity and mounting pattern according to ISO 7368.
•
Monitored closed position.
•
Inductive switch CE conform.
•
Optional poppet sealing.
•
8 sizes NG16 up to NG100.
Ordering Information
Hydraulically
Operated
D
2/2 Way
Valve
C 00
Code Description
16 NG16
25 NG25
32 NG32
40 NG40
50 NG50
63 NG63
80 NG80
100 NG100
Poppet
Shape
10
Cavity
and
Mounting
Pattern
ISO 7368
0
Valve
Size
Code Description
L 0.1 Bar (1.5 PSI)
N 0.5 Bar (7.3 PSI)
S 1.6 Bar (23.2 PSI)
U 4.0 Bar (58.0 PSI)
Weight:
C10DEC*16 1.5 kg (3.3 lbs.)
C10DEC*25 2.7 kg (6.0 (lbs.)
C10DEC*32 4.3 kg (9.5 lbs.)
C10DEC*40 7.4 kg (16.3 lbs.)
C10DEC*50 12.0 kg (26.5 lbs.)
C10DEC*63 23.0 kg (50.7 lbs.)
C10DFC*80 53.0 kg (116.9 lbs.)
C10DFC*100 89.0 kg (196.2 lbs.)
Spring
Seals
Code Description
Omit Nitrile
V Fluorocarbon
Inductive
Monitoring
German Trade
Association
Certificate
00 077
1)
C
Cover
101
Slip-in
Cartridge
E
Poppet
Seal
Orifice
99
1
Code Description
99 Without Orifice,
Open Orifice Options
Code Description
Omit None
X425 Only with
Spring Codes
S and U
Orifice (See
Accessories)
1) Certificate only for NG16-NG63
Code Description
E NG16-NG63
F NG80 - NG100
Design
Series
C10D_C.indd, ddp
132
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Slip-in Cartridge Valves
Catalog HY14-3200/US
Series C10D*CTechnical Information
Performance Curve
Attention! The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Seal and Bolt Kits
Orifice Recommendation and Thread
Orifices Ø in mm, thread in NPT
Orifice NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
No.: 1 1/16 Ƙ0.8 1/16 Ƙ1.2 1/16 Ƙ1.5 1/8 Ƙ2.0 1/8 Ƙ2.5 1/8 Ƙ3.0 1/8 Ƙ3.0 1/8 Ƙ3.0
Nominal Size 16 25 32 40 50 63 80 100
Seal Kit
Fluorocarbon
SK-CBE160V
SK-CBE250V
SK-CBE320V
SK-CBE400V
SK-CBE500V
SK-CBE630V
SK-CBE800V
SK-CBE100V
Nitrile SK-CBE160 SK-CBE250 SK-CBE320 SK-CBE400 SK-CBE500 SK-CBE630 SK-CBE800 SK-CBE100
Bolt Kit BK414 (BK84) BK391 (BK77) BK415 (BK85) BK416 (BK86) BK417 (BK87) BK418 (BK88) BK419 BK420
Recommended
Torque
27 Nm
(19.9 lb.ft.)
94 Nm
(69.3 lb.ft)
234 Nm
(172.6 lb.ft)
460 Nm
(339.3 lb.ft)
460 Nm
(339.3 lb.ft)
1570 Nm
(1157.9 lb.ft)
935 Nm
(689.6 lb.-ft.)
1910 Nm
(1408.6 lb.-ft.)
C10D_C.indd, ddp
133
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Slip-in Cartridge Valves
Catalog HY14-3200/US
Series C10D*CTechnical Information
General
Size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Interface
2-way slip-in cartridge valve according to ISO 7368
Mounting Position
Unrestricted
Operation
Hydraulic
Ambient Temperature
-40°C to +60°C (-40°F to +140°F)
Hydraulic
Maximum Operating Pressure
350 Bar (5075 PSI)
Nominal Flow LPM
āˆ†p = 5 Bar (73 PSI) GPM
220
(58)
450
(119)
900
(238)
1300
(344)
1800
(476)
3600
(952)
5000
(1322)
7500
(1984)
Fluid
Hydraulic oil according to DIN 51524 ... 525
Viscosity Recommended
30 to 80 cSt (mm
2
/s)
Viscosity Permitted
20 to 380 cSt (mm
2
/s)
Fluid Temperature Recommended
+30°C to +50°C (+86°F to +122°F)
Fluid Temperature Permitted
-20°C to +60°C (-4°F to +140°F)
Filtration
NAS 1638 class 9, to be achieved by ß10 > 75 ISO 18/16/13
Control Volume at
Maximum Stroke cm
3
2.03 6.45 12.21 20.32 39.40 94.56 950 1300
Control Surface
(Surface C = 100%) A/B
Approximately 60% / 40% related on surface C
Opening Pressure
Flow Direction B to A
L = 0.25 Bar (3.6 PSI), N 1.25 Bar (18.1 PSI),
S = 4.0 Bar (58.0 PSI), U = 10.0 Bar (58.0 PSI)
Opening Pressure
Flow Direction A to B
L = 0.16 Bar (2.3 PSI), N 0.85 Bar (12.3 PSI),
S = 2.7 Bar (39.2 PSI), U = 6.6 Bar (95.7 PSI)
Electrical (Position Control per IEC 61076-2-101 (M12x1) NG16 to NG63
Protection Class
IP65 in accordance with EN60529 (plugged and mounted)
Ambient Temperature
0°C to +50°C (+32°F to +122°F)
Supply Voltage / Ripple
18V to 42V / 10%
Current Consumption without Load
≤30mA
Output Current per Channel, Ohmic
400mA, maximum
Output Load per Channel, Ohmic
100k Ohm, minimum
Output Drop at 0.2A
≤1.1 VDC, maximum
Output Drop at 0.4A
≤1.6 VDC, maximum
EMC
EN50081-1 / EN50082-2
Ambient Field Strength
<1200A/m, maximum tolerance
Distance to Next AC Solenoid
>0.1 m (3.9 in.), minimum
Interface
Mx12x1
Wiring
5 x 0.25 mm
2,
minimum, brad shield recommended
Wiring Length
50 m (164 ft.), maximum recommended
Specifications
M12 Pin Assignment
1 + Supply 18...42V
2 Normally open
3 0V
4 Normally closed
5 Earth ground
C10D_C.indd, ddp
134
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Slip-in Cartridge Valves
Catalog HY14-3200/US
Series C10D*CTechnical Information
Extract from the German Trade Association Certificate (Applies to NG16 to NG63 only)
Fachausschuss Maschinenbau,
Hebezeuge, Hütten- und
Walzwerksanlagen
Prüf- und Zertifizierungsstelle
im BG-PRÜFZERT
Hauptverband der gewerblichen
Berufsgenossenschaften
Name und Anschrift Parker Hannifin GmbH
des Bescheinigungsinhabers: Hydraulic Controls Division
(Auftraggeber) Gutenbergstr. 38 - 40, D- 41564 Kaarst
Name und Anschrift Parker Hannifin GmbH
des Herstellers: Hydraulic Controls Division
Gutenbergstr. 38 - 40, D- 41564 Kaarst
Zeichen des Auftraggebers: Zeichen der Prüf- und Zertifizierungsstelle:
MHHW 612.1:612.28-UB Gb/bt
Produktbezeichnung: 2/2- Wegesitzventil mit Überwachung
Einbauventil nach DIN 24342 (entspricht DIN ISO 7368)
Typ: C10 DEC 101.....
Das geprüfte Baumuster entspricht den einschlägigen Bestimmungen der EG-Maschinenrichtline 2006/42/EG.
Bescheinigungs-Nummer
00 077
Electrical Specifications
M12 Pin Assignment
1 + U
S
10...30V
2 Out A: not connected
3 0V
4 Out A: normally closed
Definition
Start position monitored:
The switching point of the inductive switch is within the closed position of the poppet.
After the inductive switch changes the signal the valve opens.
Electrical (Position Control per IEC 61076-2-101 (M12x1) NG80 to NG100
Protection Class
IP65 in accordance with EN60529 (plugged and mounted)
Ambient Temperature
0°C to +50°C (+32°F to +122°F)
Supply Voltage U
s
/ Ripple
10V to 30V / 10%
Current Consumption without Load
≤10mA
Output Current per Channel, Ohmic
200mA, maximum
Output Load per Channel, Ohmic
100k Ohm, minimum
Output Drop at 0.2A
≤2 VDC, maximum
EMC
EN61000-6-4 / EN61000-6-2
Distance to Next AC Solenoid
>0.1 m (3.9 in.), minimum
Interface
Mx12x1
Wiring
3 x 0.14 mm
2,
minimum, brad shield recommended
Wiring Length
50 m (164 ft.), maximum recommended
C10D_C.indd, ddp
135
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Slip-in Cartridge Valves
Catalog HY14-3200/US
Series C10D*C
Inch equivalents for millimeter dimensions are shown in (**)
Nominal Size H h b1 d1 d2 t2
+0.1
16
130.0
(5.12)
40.0
(1.57)
79.0
1)
(3.11)
32.0
(1.26)
25.0
(0.98)
56.0
(2.20)
25
135.0
(5.31)
45.0
(1.77)
85.0
(3.35)
45.0
(1.77)
34.0
(1.34)
72.0
(2.87)
32
140.0
(5.51)
50.0
(1.97)
102.0
(4.02)
60.0
(2.36)
45.0
(1.77)
85.0
(3.35)
40
150.0
(5.91)
60.0
(2.36)
125.0
(4.92)
75.0
(2.95)
55.0
(2.17)
105.0
(4.13)
50
160.0
(6.30)
70.0
(2.76)
140.0
(5.51)
90.0
(3.54)
68.0
(2.68)
122.0
(4.80)
63
175.0
(6.89)
85.0
(3.35)
180.0
(7.09)
120.0
(4.72)
90.0
(3.54)
155.0
(6.10)
80
195.0
(7.68)
105.0
(4.13)
250.0
(9.84)
145.0
(5.71)
110.0
(4.33)
205.0
(8.07)
100
210.0
(8.27)
120.0
(4.72)
300.0
(11.81)
180.0
(7.09)
135.0
(5.31)
245.0
(9.65)
1)
Width 65mm (2.56 in.)
Cavity and mounting patterm according to ISO7368
Dimensions
NG16 to NG63 NG80 to NG100