Proportional Flow Regulator Valve
Series HP02P 21Technical Information
Specifications
Rated Flow @ 2 to 1 19 LPM (5 GPM)
210 Bar (3000 PSI)
Preferable Input Port 1
Port For Best
Hysteresis
Hysteresis @ <10%
100 Hz PWM
Variation of Flow Standard Model
@ 35% of Rated Up To ±20% Of Rated Flow
Current & Constant Model “L”
∆∆
∆∆
∆P Maintained By ±7% Of Rated Flow
Pressure
Compensator
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .08 kg (.17 lbs.)
Cavity 2X
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Flow Regulator
Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.
Features
•
Analog Proportional Partially Pressure Compensated
Flow Regulator regulates flow proportionally to the input
solenoid current
•
The valve is designed to be used in applications where
fine pressure compensation is not required and an
economical solution is important
•
One piece cartridge housing ensures internal
concentricity
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
Nonmagnetic spool and housing assembly
•
Factory-adjusted low variation option (Model “L”) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.
•
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(2)
(1)
(1)
(2)
2 to 1
1 to 2
Pressure
35
500
Bar
PSI
70
1000
105
1500
0
140
2000
175
2500
210
3000
0
Flow
15.2
22.8
7.6
4
6
2
8 30.4
GPM LPM
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow Regulation (Measured at De-Energized Coil)
Input Current (%)
8020 40 60
0
100
0
4 15.2
2 7.6
6 22.8
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
2 to 1 OR 1 to 2
Catalog HY15-3501/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Proportional
Valves
Coils &
Electronics
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Bodies &
Cavities
Solenoid
Valves
Proportional Flow Regulator Valve
Series HP02P 21
PV44
Technical Information
Filter
Screen
Override
Option
Coil
Type
Coil
Termination
Code Filter Screen
0 Not Available
Coil
Voltage
HP02P
08 Size
Proportional
Valve
Style
Code Override Option
0 Not Required
5 Detented M.O.
(Infinite Control)
Dimensions
Millimeters (Inches)
Ordering Information
THIRD-ANGLE
PROJECTION
Code Style (Maximum
Regulated Flow)
21 High Flow (‘SP’ Coil)
19 LPM (5 GPM)
Code Porting
513 3/8″ SAE
515 1/4″ BSP
Body MaterialPorting
Code Body Material
A Aluminum
S Steel
Line Body
LB10
Order Bodies Separately
Code Seals / Kit No.
N Nitrile / Buna-N (Std.)
(SK30076N-1)
V Fluorocarbon /
(SK30076V-1)
Seals
21
Flow
Variation
Code Flow Variation
Omit Standard Up to ±20%
of Rated Flow
L Low Variation
(±7% of Rated Flow)
62.7
(2.47)
19.8
(0.78)
33.8
(1.33)
Manual Override
(Infinite Control)
3/4-16 UNF
15.9
(0.63)
(1)
(2)
XXVDC XXW
CCX XXX H
MADEINU.S.A.
PAT.XXXXXXX
82.04
(3.23)
28.5
(1.12)
5.59
(0.22)
39.6
(1.56)
13.21
(0.52)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque
7/8 Hex.
27 Nm (20 lb. ft.)
Torque
See Super Coil
1/2" I.D.
Information For
Terminal Connectors
Code Coil Voltage
Omit Without Coil
D012 12 VDC
D024 24 VDC
Code Coil Type
Omit Without Coil
SP Super Coil - 19 Watts
Code Coil Termination
Omit Without Coil
D DIN Plug Face
A Amp Jr. Timer*
L Dual Lead Wire*
H Molded Deutsch*
See Super Coil 1/2
″″
″″
″
I.D.
*DC Only
NOTE: Requires 2X Cavity