50P Series
High Pressure Filters
136
137
50P Series
Applications
Applications for 50P series filters
- Automotive specified equipment
- Hydrostatic transmission circuits
- Servo and proportional controls
- Offshore drilling rigs
- Mining equipment
- Power units
The design objective for all Parker
filters is to achieve a sensible balance
between cost and performance.
We use state of the art technology
to arrive at innovative yet practical
designs, which are cost effective for
OEM’s and users alike.
The 50P series allows you to
customize each filter to closely match
your needs. Choose the options
which best fit your application. No
need to waste money on features you
don’t need.
The 50P series filters are base
mounted, which provides several
possible advan tages. The bowl
up mounting makes servicing the
elements quick and easy. Simply
remove the top cover to access
the element. A drain port is provided
to allow oil be removed from filter
prior to element servicing. This
design reduces the possibility of oil
spillage and injury to maintenance
personnel.
The 50P series has optional manifold
porting for space saving design
that re duces the number of fittings
and potential leak points. The
porting is also designed to match
the installation of many other
manufacturers. Most important,
the 50P series meets the SAE HF4
automotive standard.
Vent Plug
- Purge all air from
filter assembly
- Improves system
performance
Bowl
- Single or double
length
Head
- Ductile iron
construction-
SAE or manifold
ports
- Meets SAE HF4
automotive
specification
Drain Plug
(not visible)
- Drain oil for
easy service
Indicators
- Visual or
electrical/visual
- Several connector
options
Cover
- Durable ductile iron
- Top service
elements
- No oil spills during
service
Bypass
(not visible)
- Cartridge style
- Precision matched
assemblies
138
50P Series
Features
O-Ring Seal
- Positive sealing for optimum
el e ment efficiency
Plastic End Caps
- Excellent corrosion
pro tection
- Laser marked for clear
long lasting identification
Microglass III Media
- Multi-layer for high capacity and
high efficiency
- Four different micron sizes
available
- Wire reinforced to prevent pleat
bunching
Spiral Support Cylinders
(Not Visible)
- High strength consistent support
- Continuous length eliminates
leak points and increases
surface area
Meets SAE HF4 specificaton
for automotive uses
Feature Advantage Benefit
  
  

 
  
to servicing
  
from elements

  
  
  
 
pleat bunching

50P Series
50PR Reverse Flow Filter

transmission loops because of it’s capability to
handle reverse flow.
Closed circuit HSTs frequently reverse direction
causing flow to reverse in the fluid lines. Pressure
filters installed between pump and motor must be able
to handle reverse flow without having contaminant
washed off of the elements and back into the system.
To prevent such an occurrence, the filters require the
use of internal check valves to direct the flow through
the element in one direction and around the element in
the other. Parker’s internal check valve design
minimizes additional pressure loss and eliminates the
cost associated with external valves and fittings. Also
the inter nal design keeps the envelope dimensions of
the filter to a minimum as can be seen on the
installation drawing.
Sizing 50PR Filter Assemblies
To accurately determine the total pressure loss that will
be seen when used in your system, the following steps
should be taken.

the pressure drop for the maximum system flow on


2. Examine the appropriate pressure loss curve for the
media and bowl length combination. These curves
are found in the Element Performance Data section.
3. Find the pressure drop for the maximum flow rate


4. Find the empty housing pressure drop for the
maximum flow rate through the filter and record

5. Add the values obtained in steps 1 and 3, then
subtract out the value from step 4. The resultant
pressure loss should not exceed 1/3 of the bypass
valve or indicator you intend to select. If this ratio
exceeds 1/3, then a double length housing or other
media grade may need to be considered.
Contact the Hydraulic Filter Division if there
is any doubt as to the total pressure loss you
have calculated.
Bypass Valve
50PR Schematic
RFC
Typical FLow/Pressure Curves For 50 PR
1.75
1.5
1.25
1
0.75
0.5
0.25
0
25
20
15
10
5
0
(BAR)
DIFF. PRESS.
(PSI)
0 10 20 30 40 50 60 70 80 90 100
(GPM)
FLOW
(LPM)
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375
200 SUS200 SUS
FORWARD FLOW (R.F.C.V. ONLY)FORWARD FLOW (R.F.C.V. ONLY)
REVERSE FLOW (TOTAL)REVERSE FLOW (TOTAL)
REVERSE FLOW CHECK VALVEREVERSE FLOW CHECK VALVE
140
50P Series
50P-1 Element Performance
Efficiency %
Efficiency
Beta Rating
1000
10000
99.9
99.5
99.0100
200
20
2
50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
LPM
25
20
15
10
5
0
02Q
20Q
10Q
PSID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
05Q
0 50 100 150 200 250 300 350
0 20 40 60 80 100
LPM
25
20
15
10
5
0
PSID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
Empty Housing
0 50 100 150 200 250 300 350
0 20 40 60 80 100
Flow vs. Pressure Loss
0
20
40
60
80
100
0
1
2
3
4
5
6
Capacity grams
PSID BAR
Capacity
5Q
2Q
20Q
10Q
0 20 40 60 80 100 120
Results typical from Multi-pass tests run per test standard ISO 16889 @ 50 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
141
50P Series
50P-2 Element Performance
Efficiency %
Efficiency
Beta Rating
1000
10000
99.9
99.5
99.0100
200
20
2
50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
25
20
15
10
5
0
02Q
20Q
10Q
05Q
LPM
PSID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
0 100 200 300 400 500
0 30 60 90 120 150
25
20
15
10
5
0
LPM
PSID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
Empty Housing
0 100 200 300 400 500
0 30 60 90 120 150
0
1
2
3
4
5
6
Capacity grams
0
20
40
60
80
100
PSID BAR
Capacity
20Q
10Q
2Q
5Q
0 50 100 150 200 250 300
Flow vs. Pressure Loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 80 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
142
50P Series
50P-3 Element Performance
Efficiency %
Eciency
Beta Rating
1000
10000
99.9
99.5
99.0 100
200
20
2
50.0
95.0
Micron Size
(
c
)
0 4 8 12 16 20
2Q2Q2Q
5Q5Q5Q
20Q20Q20Q
10Q10Q10Q
LPM
25
20
15
10
5
0
02Q
20Q
10Q
P
S
ID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
05Q
0 100 200 300 400 500
0 30 60 90 120 150
Flow vs. Pressure Loss
0
20
40
60
80
100
0
1
2
3
4
5
6
Capacity grams
PSID BAR
Capacity
5Q
2Q
20Q
10Q
0 50 100 150 200 250 300 350 400
Results typical from Multi-pass tests run per test standard ISO 16889 @ 80 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
25
20
15
10
5
0
LPM
PSID
GPM
1.5
1.0
0.5
0.0
BAR
150SUS
Empty Housing
0 100 200 300 400 500
0 30 60 90 120 150
143
50P Series
Specifications
162.6
6.40
68.1
SAE5 VENT






OPTIONAL


158.8
6.25
161.8
6.37
“YY” “PP”
2.68
Pressure Ratings:
Maximum Allowable Operating Pressure



Element Collapse Rating:


Operating Temperatures:

o
F (-40
o

o
F (107
o


o
F (-26
o

o
F (135
o

Filter Materials:


Indicators:


leads or connection as selected.
5A @ 240VAC
3A @ 28VDC
SPDT
Color Coding:
 
 
 
Shipping Weights (approximate):






127.0
5.00

42.8

57.2
114.3

3.86
4.50
14.3
.563
2.25
.0775
1.685
1.375
.31
50.8
2.00
63.5
2.50
Linear Measure:
millimeter
inch
34.8
1.37

3.63
12.7
.50


Z
SAE5

OPTIONAL




INLET



DEEP

X
22.4
.88

3.125

1.56
34.8
1.37
38.1
1.50
18.3
.72
36.5
1.437
12.7
.50


D
Drawings are for reference only.
Contact factory for current version.
387.1
15.24
404.6

622.8
24.52
640.3
25.21
254.0
10.00
254.0
10.00
508.0
20.00
508.0
20.00
X
Z
50P-1 50PR-1 50P-2 50PR-2 50P-3
Dimensions=
mm/inches
850.4
33.48
760.2
30.00
387.1 404.6 622.8 640.3
144
50P Series
Parts List and Service Instructions
Element Service Instructions
When servicing the 50P filter, use the
following procedure.
A. Stop the system’s power unit.
 
or line.
C. If desired, oil can be drained
from filter housing by removing
the drain port plug located in the
head.
 
and remove.
 
F Place new, clean element into
housing centering element
over locator.
 
necessary
H. Apply cover to filter and tighten to
45-50 ft. lbs.
 
20-25 ft. lbs.
Parts List
Index Description Part Number 50P/PR
1 Head Assembly Consult Factory
2 Bowl Consult Factory
3 Cover 
4 Cover O-Ring
 
 
5 Vent Plug 927363
 
 
6 Element See model code page
7 Drain Plug 927363
 
 
8 Bypass Valve

 
 
 
 
Indicator Kits
 
 
 
 
 
O-Ring, Manifold Port
 
 

1
8
2
6
5
3
4
7
145
50P Series
How to Order
50P/50PR Replacement Elements (Fluorocarbon)
Standard Collapse High Collapse
Media Single Double Triple Media Single Double Triple
20Q 931018Q 931020Q 933489Q 20QH 930438Q 931490Q 936449Q
10Q 932670Q 932679Q 933488Q 10QH 932676Q 932685Q 936448Q
05Q 932669Q 932678Q 933487Q 05QH 932675Q 932684Q 936447Q
02Q 932668Q 932677Q 933486Q 02QH 932674Q 932683Q 936446Q
Please note the bolded options reect
standard options with a reduced lead-time.
Consult factory on all other lead-time
options.
BOX 6: Bypass and Indicator Setting
BOX 2: Basic Assembly
Symbol Description
50P 5000 PSI (MAOP)
50PR* Reverse ow
hydrostatic version
BOX 3: Length
Symbol Description
1 Single
2 Double
3 Triple
Symbol Pressure Setting
35 35 psid
50 50 psid
90 90 psid
BOX 7: Ports
Symbol Description
PP SAE-24 straight thread
YY SAE 1½” ange face (J518)
XX 1
3
/
8
” manifold ports on
bottom of head
BOX 8: Options
Symbol Description
1 None
11 Blocked bypass
BOX 1: Seals
Symbol Description
None Buna
F3 Fluorocarbon
E8 EPR
Symbol Description
P Port plugged
PL Port plugged, left side
M Visual indicator
ML Visual indicator, left side
E Electrical indicator with
wire leads and conduit
connection
EL Electrical indicator with
wire leads and conduit
connection, left side
D Electrical indicator w/
ANSI/B.93.55M 3-pin
Brad Harrison style
connection
DL Electrical indicator w/
ANSI/B.93.55M 3-pin
Brad Harrison style
connection, left side
BOX 5: Indicators
BOX 4: Element Media
Symbol Description
20Q Microglass III
10Q Microglass III
05Q Microglass III
02Q Microglass III
Note: For high collapse 2000 psid rated
elements, add “H” behind Q.
Note: Left side is on viewer’s left when looking
into inlet port.
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
*Note: Not available in triple length. Must select
“1” or “2” in BOX 3
F3 50P 1 10Q DL 90 PP 1