3-15
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Characteristics
The D*1FW pilot-operated proportional DC valve is avail-
able in size NG10 (CETOP5), NG16 (CETOP7) and NG25
(CETOP8).
Typical applications include reproducible control of ac-
tuator speed in rapid / slow speed profiling, and smooth
acceleration and deceleration performance.
In combination with the digital power amplifier PWD00A-
400, the valve parameters can be saved, changed and
duplicated.
Technical features
• Progressive flow characteristics for
sensitive adjustment of flow rate
• Fail-safe centre position
• Center position monitoring optional
D31FW
3-16
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
D31 D41 D91
75 --
- 200 -
--400
Ordering Code
Code Inlet Drain
1 Internal External
2 External External
4 Internal Internal
5 External Internal
D
F
DC
valve
Spool
type
Flow
Code
L
Solenoid description
6 V/2.5A
1
Nominal
size
W
Valve
accessories
Solenoid
description
(other current
on request)
Pilot
connection
C
Nominal size
NG10 / CETOP 5
NG16 / CETOP 7
NG25 / CETOP 8
Code
3
4
9 *
Design
series
Flow
control
Seal
NBR
(different
seal
compound
on request)
NW
Please order plug/s separately.
See chapter 3 accessories.
Flow [l/min]
at ∆p = 5bar per metering edge
Code
C
F
H
Code
Standard
Monitor switch
0
8
Valve accessories
Code
E01
E02
B31
B32
Spool type
Q
B
= Q
A
/2
Q
B
= Q
A
/2
* with enlarged connections
Ø 32 mm
3-17
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Technical Data
General
Design Pilot-operated DC Valve
Actuation Proportional solenoid
Size NG10 NG16 NG25
(CETOP 5) (CETOP 7) (CETOP 8)
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position Any
Ambient temperature [°C] -20...+60
Weight [kg] 7.1 10.8 19
Hydraulic
Max. operating pressure [bar] Ports P, A, B, T, X max. 350; Port Y max. 10
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+60
Viscosity permitted [mm
2
/s] 20...380
Viscosity recommended [mm
2
/s] 30...80
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1683: 7)
Flow nominal at ∆P=5 bar
per control edge * [l/min] 75 200 400
Leakage at 100 bar [ml/min] 100 200 600
Pilot supply pressure [bar] 20-350 (optimal dynamics at 50)
Pilot flow at 100bar [l/min] <1.2
Pilot flow, step response [l/min] 0.8 1.7 3.8
Static / Dynamic
Step response at 100% step [ms] 60 75 100
Hysteresis [%] <5
Electrical characteristics
Duty ratio [%] 100%
Protection class IP54
Solenoid Code L
Supply voltage [V] 6
Current consumption [A] 2.5
Resistance [Ohm] 2.2
Coil insulation class F (155 °C)
Electrical connection 2+PE acc. EN 175301-801
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield
Wiring lenght max. [m] 50
Electrical monitor switch
Protection class IP65
Ambient temperature [°C] 0-70
Supply voltage/ripple [V] 18...42, ripple <10% eff.
Current consumption
without load [mA] <30
Max. output current
per channel, ohmic [mA] 400
Min. output load
per channel, ohmic [kOhm] 100
Max. output drop at 0.2A [V] <1.1
Max. output drop at 0.4A [V] <1.6
EMC EN 50081-1 / EN50082-2
Max. tol. ambient field
strength [A/m] 1200
Min. distance to next AC
solenoid [m] 0.1
Interface 4+PE acc. IEC 61076-2-101 (M12)
Wiring min. [mm²] 5x0.5 (AWG 20) overall braid shield
Wiring lenght max. [m] 50
* Flow rate for different ∆p per control edge: Q
x
= Q
Nom.
·
√
∆p
x
∆p
Nom.
3-18
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Flow characteristics
at ∆p = 5 bar per metering edge
Characteristic Curves / Plugs
D*1FW
Spool code E* Spool code B*
1 = coil connection
2 = coil connection
PE = ground potential
Plugs
Solenoid coil
1 = output B (normally closed)
2 = supply (18...42 VDC)
3 = output A (normally closed)
4 = GND (0V)
5= PE
Monitor switch
3-19
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Dimensions
Pilot oil inlet (supply) and outlet (drain)
D31FW
D41FW
D91FW
3-20
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
D41FW
D31FW
NBR
BK385 4x M6x40 13.6 Nm SK-D31FW-N20
DIN 912 12.9 ±15 %
Surface finish
NBR
2x M6x55 11 Nm
BK320 4x M10x60 54 Nm SK-D41FW-N20
DIN 912 12.9 ±15 %
Surface finish
Dimensions
3-21
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Dimensions
D91FW
NBR
BK360 6 x M12x95 94 Nm SK-D91FW-N20
DIN 912 12.9 ±15 %
Surface finish
3-22
D_1FW.PMD CM
Pilot-Operated Proportional DC Valve
Series D*1FW
Catalogue HY11-2500/UK
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Notes