Proportional DC Valve
Series D*1FH
Installation Manual
9
IA HY11-5715-592 D1FH KS42 UK.INDD CM
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Min/Max-Setting
The min/max-setting option achieves a conditioning
of the valve operating range to a certain application.
The min-setting is used for valves with overlapped
main spools, it compensates for the mechanical
overlap by an offset-feature.
The max-setting limits the stroke of the valve spool,
equally the full input signal range will be preserved
and can be used with full resolution.
Both settings are provided separately for both valve
operating directions.
Diagnostic Output
To make available measurements for the momen-
tary position of the valve spool the valve electron-
ics unit provides a diagnostic output. This is avail-
able at the main connector between pin F and
supply zero (pin B) as well as on the printed circuit
board of the valve electronics unit which provides
two diagnostic sockets. The sockets take 2mm
plugs and can e.g. be used in the setting up of the
zero point.
The output is a 0...±10V signal where the value of
10V normally represents the maximum permitted
stroke of the valve spool.
The diagnostic output is short circuit proofed and
is fully operative up to a load of at least 2kOhms
or 5mA.
Position Control
The purpose of the position controller is to compare
the actual value of the spool as given by the valve
electronics sensor with the set value and provide
signals to the actuating solenoids to ensure that
the set position is achieved and maintained. The
sketch below shows the operating principle of the
control circuit.
Power Stage
In the output stage the output signal of the position
controller is converted into an activating signal for
the operating solenoids.
Keeping the power relationships at the solenoid
constant as well as the need for rapid excitation of
the solenoids is achieved with controlled current
from a constant current control stage.The solenoid
current is measured in the valve electronic unit and
compared with the set-value for current in the
constant current controller. As long as there is a
difference between set and actual current values
the output stage will change the solenoid current
in order to equalise them.The solenoid also has a
superimposed dither signal which has been care-
fully matched with the mechanics of the valve to
compensate for mechanical friction so that the
hysteresis will not influence the dynamics of the
valve.
Enable Signal Input
To switch-off the output stage the valve electronics
unit is fitted with an enable signal input which can
at any time be used to interrupt the solenoid current
irrespective of transducer signal or set value. In this
case the main spool takes up - without any delay
- the spring centered position in the valve.
A further function of the enable signal input is to
limit the output of the position control. Normally on
switching off the activated solenoid the output of
the controller would be driven into saturation by the
Integral part of the PID system. Because of this, if
the solenoid is immediately switched on again the
valve spool is for a short period of time operated
indefinetily. To avoid this, the integral part of the
controller is switched out and a limit is placed on
the controller output for as long as the enable input
is switched off. When the enable signal is switched
on again the valve spool will immediately move
from it's central position and take up the required
set position.
The enable signal input is, as far as circuitry is
concerned, completely isolated from the rest of the
electronics to keep interference from peripheral
equipment away from valve electronic unit. It re-
quires a signal in the region of 5 to 30VDC with a
current supply of about 10mA. The enable signal
is fed into the unit via the central connector between
pins B and C.