D91 Series
Directional Control
Valves
NFPA D08, Cetop 8
Catalog HY28-3800/NA
Replaces 4-AM/EN 3800
Proportional Directional Control ValvesBulletin HY28-3800/NA
1
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Technical Information Series D91FT and D91FW
General Description
The D91FT and D91FW series two-stage pilot oper-
ated proportional directional control solenoid valves
are available with or without integrated control elec-
tronics. Valves are available in sizes NG25 (CETOP 8).
Typical applications include reproducible control of
actuator speed in rapid/slow speed profiling, and
smooth acceleration and deceleration performance.
Features
•
Standard DIN/ISO/CETOP/NFPA interfaces.
•
Optional integrated control electronics with ramp
adjustment.
•
Low leakage.
•
Progressive flow characteristics for improved low flow
resolution.
•
Spring centered main stage spool.
•
Wide selecton of spool options and flow capacity.
•
2:1 ratio spool options.
Series D91FW without integrated electronics
Series D91FT with integrated electronics
Supply Voltage 14.5 to 30 VDC
Current 3 amps
Command Signal
(impedance) 0 ± 10 VDC (100K)
(select by ordering code) 0 ± 20 mA (500 ohms)
Command Polarity Pin ‘D’ more positive
than ‘E’; flow P to B
Ramp Time Adjustment 0 to 3 seconds
Environmental Protection
Class NEMA 1 (IP54)
Mating Connector
(order separately) (7-pin CE) Part #167-00032-0
Solenoid (order code “L”)
Nominal Resistance 2.2 ohms
Nominal Current 2.5 amps
Nominal Voltage 6 volts
Solenoid (order code “X”)
1)
Nominal Resistance 9.8 ohms
Nominal Current 1.3 amps
Nominal Voltage 16 volts
Environmental Protection Class NEMA 1 (IP54)
Mating Connectors Part 167-01008-8 (blk)
Solenoid (DIN 4350) Part 167-01007-8 (gr)
(optionally included with valve)
1) For use with 24 volt based electronic driver cards.
Repeatability %<2
Operating Pressure
Port P, A, B Bar (PSI) 345 (5000) max.
Port P, internal pilot 20 (290) min.
Port T, internal drain 10 (150) max.
Port T, external drain 345 (5000) max.
Port Y, pilot drain 10 (150) max.
Port X, external pilot 20-345 (290-5000)
Specifications
Interface DIN (NFPA/ISO/CETOP) NG25 (08)
Flow Rating @10 Bar (150 PSI) ∆p (P→A, B→T)
(Spool options up to) LPM (GPM) 400 (106)
Pilot Flow — Continuous LPM (GPM) 1.2 (0.3)
Step Response (time to reach 90% of a 100% step command)ms 100
Weight kg (lbs.) 19 (42)
Hysteresis %<5
Fluid Cleanliness Level ISO Class 16/13
Fluid Viscosity,
Recommended 80 – 1000 SSU
Fluid Temperature, 0°C to +60°C
Recommended (+32°F to +140°F)
Ambient Operating -20°C to +60°C
Temperature (-4°F to +140°F)
Proportional Directional Control Valves
2
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Bulletin HY28-3800/NA
Ordering Information Series D91FT
Code Description
9 NG25/CETOP 8
Weight:
NG25 19.0 kg (42.0 lbs.)
Code Description
N Nitrile
V Fluorocarbon
Code Pilot Drain
1 Internal External
2 External External
4 Internal Internal
5 External Internal
Flow at
∆∆
∆∆
∆p 5 Bar (72.5 PSI) per metering edge
Code D91
LPM (GPM)
F 300 (79)
Code Description
F Voltage Input 0… ±10V
(with reference output
+10V/-10V)
G Current Input
0... ±20mA
1) Reduced Flow Rate on Port B,
Nominal Flow Rate on Port A
Code A* for spool Q
B
>Q
A
optional
Code V-Notch
Q
A
=Q
B
Q
A
>Q
B
1)
Spool Type
E21 B41
E22 B42
V-Notch Spool Options - Spool Type and Flow Codes
Design
Series
NOTE:
Not required
when ordering.
D
Directional
Control
Valve
Size
and
Interface
Pilot
Operated
Flow
Control
Electronic
Accessories
Integrated
Electronics
Flow Electronic
Variation
Valve
Accessories
F0
1T
Spool
Type
Style
Seal
Pilot
Connection
C
Mating connector not included in delivery.
Code Description
0 Standard, no accessories
2 Pilot Pressure Reducer
(2)
(2) Recommended for pilot
pressure applications
> 205 Bar (3000 PSI)
9
XB962
Code Sine
Q
A
=Q
B
Q
A
>Q
B
1)
Spool Type
E01 B31
E02 B32
E04 –
E05 –
Flow at
∆∆
∆∆
∆p 5 Bar (72.5 PSI) per metering edge
Code D91
LPM (GPM)
H 400 (106)
Sine Spool Options - Spool Type and Flow Codes
Proportional Directional Control ValvesBulletin HY28-3800/NA
3
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Ordering Information Series D91FW
Code Description
9 NG25/CETOP 8
Code Pilot Drain
1 Internal External
2 External External
4 Internal Internal
5 External Internal
Code Description
W Socket Connector
without Plugs
Design
Series
NOTE:
Not required
when ordering.
D
Directional
Control
Valve
Size
and
Interface
Pilot
Operated
Flow
Control
Solenoid
Variation
Open
Loop
Flow Solenoid Valve
Accessories
FW
1W
Spool
Type
Style SealPilot
Connection
C
Weight:
NG25 19.0 kg (42.0 lbs.)
Flow at
∆∆
∆∆
∆p 5 Bar (72.5 PSI) per metering edge
Code D91
LPM (GPM)
F 300 (79)
Code Sine
Q
A
=Q
B
Q
A
>Q
B
1)
Spool Type
E01 B31
E02 B32
E04 –
E05 –
Flow at
∆∆
∆∆
∆p 5 Bar (72.5 PSI) per metering edge
Code D91
LPM (GPM)
H 400 (106)
Sine Spool Options - Spool Type and Flow Codes
V-Notch Spool Options - Spool Type and Flow Codes
1) Reduced Flow Rate on Port B,
Nominal Flow Rate on Port A
Code A* for spool Q
B
>Q
A
optional
Code V-Notch
Q
A
=Q
B
Q
A
>Q
B
1)
Spool Type
E21 B41
E22 B42
Code Description
N Nitrile
V Fluorocarbon
Code Description
L
2)
6 VDC/2.5A
X 16 VDC/1.3A
2) Standard
Code Description
0 Standard,
no accessories
2 Pilot Pressure
Reducer
(3)
(3) Recommended for
pilot pressure
applications
> 205 Bar (3000 PSI)
9
XB962
Proportional Directional Control Valves
4
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Bulletin HY28-3800/NA
Technical Information Series D91FT and D91FW
Block Diagram (D91FT)
differential
amplifier
power
stage
U
I
U
I
D
voltage input 0…±10V
current input 0…±20mA
protective earth
(Note 1)
reference output
only with electronic variation F
(Note 1)
0V
MIN MAX
ramps
AA
B
D*1FT
B
supply
voltage
E
G
(+) A
(
_
)
B
(
_
)
F
(+) C
dither
voltage converter
Note 1) Refer to ordering code page.
+ CMD
– CMD
+24
0V
+10V
-10V
1 = coil connection
2 = coil connection
PE = ground potential
Integrated Control Electronics (D91FT)
Arrangement of Potentiometers
Wiring D91FW — Solenoid Coil
(without integrated electronics)
X4X1 X3X2
P4 P5 P6 P1 P2 P3
BBBAAA
-
+
-
+
-
+
-
+
-
+
-
+
Connectors for
solenoids
Solenoid Solenoid
on plug side
adjustments
ramp
ramp
MIN
MIN MAXMAX
Command Signal (%)
0 20 40 60 80 100
0
25
50
75
100
Flow (% of Nominal Flow)
D91FW Flow Characteristics
at p = 5 Bar (72.5 PSI) / metering edge
V-Notch
Spool
Sine
Spool
Command Signal (%)
0 20 40 60 80 100
0
25
50
75
100
Flow (% of Nominal Flow)
D91FT Flow Characteristics
(with integrated control electronics)
at p = 5 Bar (72.5 PSI) / metering edge
Sine
Spool
V-Notch
Spool
Performance Curves
Proportional Directional Control ValvesBulletin HY28-3800/NA
5
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Technical Information Series D91FT and D91FW
Wiring Guidelines
Conformance to the CE RFI/EMC susceptibility and
emissions regulations require valves with integrated
electronics be properly wired and grounded. The wiring
diagram below suggests proper practices, and should
be used as a guide for wiring any new application. In
some retrofit applications it may be necessary to
significantly alter an existing wiring layout and ground-
ing methods to achieve the desired RFI/EMC immunity
and avoid ground loops. Note that an improperly wired
application can render a system unusable.
Valves should be wired to the user control cabinet by
shielded cable where the shield is grounded at both
ends. These ground points must be very low imped-
ance earth grounds, and proper wiring practices are
required to avoid system ground loops. In some
RFI/EMC Immunity for valves with integrated electronics
applications it may be necessary to install a low
impedance ground strap between the valve or manifold
and earth to achieve a proper ground.
Note that when assembling cable/connector assem-
blies, the shield must be in electrical contact with the
connector shell to complete the shield circuit through
the valve mating receptacle. (Refer to the Accessories
section of this catalog for pre-assembled ‘EHC’ cable
assemblies)
To minimize the exposure to RFI/EMC radiation,
electronic equipment should be isolated from sources
of high-energy electromagnetic radiation such as
cables carrying high currents, radio transmitters,
electrical load control centers and contactors.
User Control Cabinet
Command Signal
Enable
Spool Position Monitor
Common
Power Supply
+24
0V
Common Grnd Point
Low Impedance
to Earth Grd
Metal Connector
Physical Contact
Low Impedance
to Earth Grd
Valve with
Onboard
Electronics
Shield
D
E
C
F
A
B
G
Pilot Connection (D91FT and D91FW)
M6
1/16
DIN906
NPTF
M6 DIN906
B
P
xy
A
T
B
A
BBP C
a
b0
a
b
0
open, closed
Pilot oil
Inlet
Drain
BC
internal
external
internal
external
external
external
internal
internal
C
B
P
P
T
Proportional Directional Control Valves
6
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Bulletin HY28-3800/NA
Dimensions Series D91FT and D91FW
Inch equivalents for millimeter dimensions are shown in (**)
D91FT
D91FW
307.0
(12.09)
116.0
(4.57)
77.0
(3.03)
230.0
(9.06)
256.0
(10.08)
57.0
(2.24)
116.0
(4.57)
231.0
(9.09)
306.0
(12.05)
230.0
(9.06)
76.0
(2.99)
57.0
(2.24)
Proportional Directional Control ValvesBulletin HY28-3800/NA
7
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Mounting Interface Dimensions Series D91FT and D91FW
Size NG25 (NFPA/ISO/CETOP 08)
mounting pattern per DIN 24340-A6
* Dimension tolerance ±0.1 mm (0.004 in.)
All other dimensions ±0.2 mm (0.008 in.)
** Port not used with valves in this catalog
d (A,B,T,) series 8: 27.0 (1.06)∅
d (P,) series 8: 26.5 (1.04)∅
d (P,A,B,T) series 9: 32.0 (1.26)∅
Location pin 7.5 (0.30)x12.0 (0.47) deep
M12x24.0 (0.94) deep
d
X
A
T
Y
B
P
142.0
(5.59)
130.2*
(5.13)
112.7
(4.44)
100.8
(3.97)
94.5*
(3.72)
77.0*
(3.03)
53.2*
(2.09)
29.4*
(1.16)
17.5
(0.69)
17.5
(0.69)
19.0
(0.75)
73.0
(2.87)
74.6
(2.94)
92.1*
(3.63)
4.8*
(0.19)
11.2
(0.44)
130.0
(5.12)
12.0
(0.47)
Location pin
12.0
(0.47)
7.5
(0.30)
x
deep
Proportional Directional Control Valves
8
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Bulletin HY28-3800/NA
General Description
Supporting accessory products for proportional valves
listed in this section include cable assemblies, connec-
tors, bolt kits, and subplates, valve drivers and power
supplies.
EHC cable assemblies are listed for specific valves, by
function, and are supplied with an installed connector
as specified at one end, pig-tails leads at the other.
Note that some valves are not shipped with a mating
connector. Mating connectors are listed by valve
application.
Bolt kits and subplates are listed by valve application.
Refer to catalog 2543/USA: Subplates and Manifolds
for more options.
Installation guides are listed in this section for supple-
mental application information.
Technical Information
EHC Cable Assemblies
Valve Connector
Application Option (1) (2) Pins Function (3) Model
D91FT CE compliant, ‘MS’ style 7 Primary cable assembly EHC158GE
Plastic 7 Primary cable assembly EHC158G
Notes: (1) CE compliant connectors are environmental resistant. Plastic and standard ‘MS’ style are not.
(2) CE compliant cable assemblies must be used to meet CE, RFI and EMC susceptibility and emissions regulations.
(3) Cable length: 4.5 meters (15 feet) standard. Additional length options available, see price list.
Cable Model – Wire Color
Pin 154LR 156R
154LRE 156RE 158 158G 158GE
A Red Black Orange Red Red
B Green Red Blue Black Black
C Black White Black Yellow Red/Bla
D White Green Grn/Yel Blue Blue
E – Orange Red Orange Orange
F – Blue White White White
G – – – Green Green
EHC Cable Assemblies
Wire Color Assignments – D91FT
Accessories
Valve Installation Guide
Installation Guides
D91FT Bul. 2580-M1/USA
Description Variation Order Number
DIN 43650 Black 167-01008-8
DIN 43650 Grey 167-01007-8
PG 9= 19 (0.75)
PG 11= 24 (0.94)
∅
∅
PG 9=~50 (1.97)
PG 11=~53 (2.09)
∅30.5
(1.20)
34.2
(1.35)
M3
Solenoid Connector – D91FW
Proportional Directional Control ValvesBulletin HY28-3800/NA
9
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Technical information
Port Port
Interface Valve Bolt Kit Qty Size Subplate
(1)
Size Location
NG25 D91FT BK228 6 1/2-13 x 3" SPD66NS35 3/4" NPTF Bottom
CETOP 8 D91FW BK360 6 M12 x 75 SPD66NAS35 3/4" NPTF Side
SPD68NS35 1" NPTF Bottom
SPD68NAS35 1" NPTF Side
SPD610NS35 1 1/4" NPTF Bottom
SPD610NAS35 1 1/4" NPTF Side
SPD610SS35 #20 SAE Bottom
SPD610SAS35 #20 SAE Side
(1) Ductile iron; maximum operating pressure: 350 Bar (5000 PSI).
Refer to valve specificatons for actual recommended maximums.
Note: All subplates listed use SAE mounting bolt hardware.
Refer to catalog HY14-2543/US for metric options.
Bolt Kits and Subplates
Accessories
Proportional Directional Control Valves
10
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Bulletin HY28-3800/NA
The items described in this document and other documents or descriptions provided by THE COMPANY, its subsidiaries and its authorized distributors
are hereby offered for sale at prices to be established by THE COMPANY, its subsidiaries and its authorized distributors. This offer and its acceptance
by any customer ("Buyer") shall be governed by all of the following Terms and Conditions. Buyer’s order for any such items, when communicated to THE
COMPANY, its subsidiary or an authorized distributor ("Seller") verbally or in writing, shall constitute acceptance of this offer.
discard or otherwise dispose of any special tooling or other property in its
sole discretion at any time.
8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,
confidential information or equipment furnished by Buyer or any other
items which become Buyer’s property, may be considered obsolete and
may be destroyed by Seller after two (2) consecutive years have elapsed
without Buyer placing an order for the items which are manufactured using
such property, Seller shall not be responsible for any loss or damage to
such property while it is in Seller’s possession or control.
9. Taxes: Unless otherwise indicated on the face hereof, all prices and
charges are exclusive of excise, sales, use, property, occupational or like
taxes which may be imposed by any taxing authority upon the manufac-
ture, sale or delivery of the items sold hereunder. If any such taxes must
be paid by Seller or if Seller is liable for the collection of such tax, the
amount thereof shall be in addition to the amounts for the items sold. Buyer
agrees to pay all such taxes or to reimburse Seller therefore upon receipt
of its invoice. If Buyer claims exemption from any sales, use or other tax
imposed by any taxing authority, Buyer shall save Seller harmless from
and against any such tax, together with any interest or penalties thereon
which may be assessed if the items are held to be taxable.
10. Indemnity For Infringement of Intellectual Property Rights: Seller
shall have no liability for infringement of any patents, trademarks, copy-
rights, trade dress, trade secrets or similar rights except as provided in this
Part 10. Seller will defend and indemnify Buyer against allegations of
infringement of U.S. Patents, U.S. Trademarks, copyrights, trade dress
and trade secrets (hereinafter ‘Intellectual Property Rights’). Seller will
defend at its expense and will pay the cost of any settlement or damages
awarded in an action brought against Buyer based on an allegation that
an item sold pursuant to this contract infringes the Intellectual Property
Rights of a third party. Seller’s obligation to defend and indemnify Buyer
is contingent on Buyer notifying Seller within ten (10) days after Buyer
becomes aware of such allegations of infringement, and Seller having sole
control over the defense of any allegations or actions including all
negotiations for settlement or compromise. If an item sold hereunder is
subject to a claim that it infringes the Intellectual Property Rights of a third
party, Seller may, at its sole expense and option, procure for Buyer the
right to continue using said item, replace or modify said item so as to make
it noninfringing, or offer to accept return of said item and return the
purchase price less a reasonable allowance for depreciation. Notwith-
standing the foregoing, Seller shall have no liability for claims of infringe-
ment based on information provided by Buyer, or directed to items
delivered hereunder for which the designs are specified in whole or part
by Buyer, or infringements resulting from the modification, combination or
use in a system of any item sold hereunder. The foregoing provisions of
this Part 10 shall constitute Seller’s sole and exclusive liability and Buyer’s
sole and exclusive remedy for infringement of Intellectual Property Rights.
If a claim is based on information provided by Buyer or if the design for an
item delivered hereunder is specified in whole or in part by Buyer, Buyer
shall defend and indemnify Seller for all costs, expenses or judgments
resulting from any claim that such item infringes any patent, trademark,
copyright, trade dress, trade secret or any similar right.
11. Force Majeure: Seller does not assume the risk of and shall not be
liable for delay or failure to perform any of Seller’s obligations by reason
of circumstances beyond the reasonable control of Seller (hereinafter
‘Events of Force Majeure’). Events of Force Majeure shall include without
limitation, accidents, acts of God, strikes or labor disputes, acts, laws,
rules or regulations of any government or government agency, fires,
floods, delays or failures in delivery of carriers or suppliers, shortages of
materials and any other cause beyond Seller’s control.
12. Entire Agreement/Governing Law: The terms and conditions set
forth herein, together with any amendments, modifications and any
different terms or conditions expressly accepted by Seller in writing, shall
constitute the entire Agreement concerning the items sold, and there are
no oral or other representations or agreements which pertain thereto. This
Agreement shall be governed in all respects by the law of the State of Ohio.
No actions arising out of the sale of the items sold hereunder or this
Agreement may be brought by either party more than two (2) years after
the cause of action accrues.
9/91-P
1. Terms and Conditions of Sale: All descriptions, quotations, propos-
als, offers, acknowledgments, acceptances and sales of Seller’s products
are subject to and shall be governed exclusively by the terms and
conditions stated herein. Buyer’s acceptance of any offer to sell is limited
to these terms and conditions. Any terms or conditions in addition to, or
inconsistent with those stated herein, proposed by Buyer in any accep-
tance of an offer by Seller, are hereby objected to. No such additional,
different or inconsistent terms and conditions shall become part of the
contract between Buyer and Seller unless expressly accepted in writing
by Seller. Seller’s acceptance of any offer to purchase by Buyer is
expressly conditional upon Buyer’s assent to all the terms and conditions
stated herein, including any terms in addition to, or inconsistent with those
contained in Buyer’s offer, Acceptance of Seller’s products shall in all
events constitute such assent.
2. Payment: Payment shall be made by Buyer net 30 days from the date
of delivery of the items purchased hereunder. Amounts not timely paid
shall bear interest at the maximum rate permitted by law for each month
or portion thereof that the Buyer is late in making payment. Any claims by
Buyer for omissions or shortages in a shipment shall be waived unless
Seller receives notice thereof within 30 days after Buyer’s receipt of the
shipment.
3. Delivery: Unless otherwise provided on the face hereof, delivery shall
be made F.O.B. Seller’s plant. Regardless of the method of delivery,
however, risk of loss shall pass to Buyer upon Seller’s delivery to a carrier.
Any delivery dates shown are approximate only and Seller shall have no
liability for any delays in delivery.
4. Warranty: Seller warrants that the items sold hereunder shall be free
from defects in material or workmanship for a period of 18 months from
date of shipment from THE COMPANY. THIS WARRANTY COMPRISES
THE SOLE AND ENTIRE WARRANTY PERTAINING TO ITEMS PRO-
VIDED HEREUNDER. SELLER MAKES NO OTHER WARRANTY,
GUARANTEE, OR REPRESENTATION OF ANY KIND WHATSOEVER.
ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO,
MERCHANTABILITY AND FITNESS FOR PURPOSE, WHETHER EX-
PRESS, IMPLIED, OR ARISING BY OPERATION OF LAW, TRADE
USAGE, OR COURSE OF DEALING ARE HEREBY DISCLAIMED.
NOTWITHSTANDING THE FOREGOING, THERE ARE NO WARRAN-
TIES WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR
PARTIALLY, TO BUYER’S DESIGNS OR SPECIFICATIONS.
5. Limitation Of Remedy: SELLER’S LIABILITY ARISING FROM OR
IN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CON-
TRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR RE-
PLACEMENT OF THE ITEMS SOLD OR REFUND OF THE PURCHASE
PRICE PAID BY BUYER, AT SELLER’S SOLE OPTION. IN NO EVENT
SHALL SELLER BE LIABLE FOR ANY INCIDENTAL, CONSEQUEN-
TIAL OR SPECIAL DAMAGES OF ANY KIND OR NATURE WHATSO-
EVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING
FROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT OR
ITEMS SOLD HEREUNDER, WHETHER ALLEGED TO ARISE FROM
BREACH OF CONTRACT, EXPRESS OR IMPLIED WARRANTY, OR
IN TORT, INCLUDING WITHOUT LIMITATION, NEGLIGENCE, FAIL-
URE TO WARN OR STRICT LIABILITY.
6. Changes, Reschedules and Cancellations: Buyer may request to
modify the designs or specifications for the items sold hereunder as well
as the quantities and delivery dates thereof, or may request to cancel all
or part of this order, however, no such requested modification or cancel-
lation shall become part of the contract between Buyer and Seller unless
accepted by Seller in a written amendment to this Agreement. Acceptance
of any such requested modification or cancellation shall be at Seller’s
discretion, and shall be upon such terms and conditions as Seller may
require.
7. Special Tooling: A tooling charge may be imposed for any special
tooling, including without limitation, dies, fixtures, molds and patterns,
acquired to manufacture items sold pursuant to this contract. Such special
tooling shall be and remain Seller’s property notwithstanding payment of
any charges by Buyer. In no event will Buyer acquire any interest in
apparatus belonging to Seller which is utilized in the manufacture of the
items sold hereunder, even if such apparatus has been specially con-
verted or adapted for such manufacture and notwithstanding any charges
paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter,
Offer of Sale
Proportional Directional Control ValvesBulletin HY28-3800/NA
11
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio, USA
Notes
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
INJURY AND PROPERTY DAMAGE.
This document and other information from THE COMPANY, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having
technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the
variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by THE COMPANY and its subsidiaries
at any time without notice.
WARNING
Parker Hannifin Corporation
Hydraulic Pump Division
14249 Industrial Parkway
Marysville, OH 43040 USA
Tel: 937-644-4435
Fax: 937-642-3639
www.parker.com/hydraulicpump
Catalog HY28-3800/NA
PDF, 3/06
©©
©©
© Copyright 2006
Parker Hannifin Corporation
All Rights Reserved.