Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-35
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
Characteristics
D5S 3-portD5S 2-port
D5S 3-portD5S 2-port
D5S 3-portD5S 2-port
Seat valves series D5S are designed for directional con-
trol functions. They enable individual hydraulic solutions
for nominal flow up to 800 l/min due to a large variety of
poppets, springs and covers, including shuttle valves,
stroke limiters, solenoid valves (VV01) and position
control.
A complete program is offered under the Parker brand:
subplate mounted valves (Series D4S - chapter 6)
SAE flange valves (Series D5S - chapter 9)
pipe mounted valves (Series D4S - chapter 10)
slip-in cartridges (Series CAR - on request)
Features
• Leak-free seat valve design
• 2- and 3-port bodies
• SAE61 flange
• Numerous pilot options
• 6 poppet types
• 4 sizes, SAE 3/4ā€œ, 1ā€œ, 1 1/4ā€œ, 1 1/2ā€œ
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-36
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
Ordering Code
Code Options
omit Standard
013
Position control
with protection
Code Port size
06 SAE ¾"
08 SAE 1"
10 SAE 1¼"
12
1)
SAE 1½"
D5S
Seat
valve
Spool
type
Nominal
size
Code Body Ports
5
3-port
Seat entry, A;
X1, Y1, M = G¼"
7
2-port
Seat entry, A;
X1, Y1 = G¼"
8
2-port
Annular entry, B;
X1, Y1 = G¼"
2)
Springs 2, 3 and 6 only
Body
B
Design
series
Seals
Code Pilot oil line in body
1
internal from A
2
internal from B
3
internal from A and B
4 external from X1
5
internal from B, external from X1
Sleeve
Switching
type
Solenoid
voltage
Code Sleeve
1 AA=95%, AB=5%
3 AA=60%, AB=40%
Code Switching type
omit
Standard
w/o vent function
09 VV01 with manual override
de-energized:
open
10 VV01 without manual override
11 VV01 with manual override
de-energized:
closed
12 VV01 without manual override
CA Shuttle valve
DA Shuttle valve
CB VV01 code 09 and shuttle valve code CA
CD VV01 code 11 and shuttle valve code CA
DB VV01 code 09 and shuttle valve code DA
DD VV01 code 11 and shuttle valve code DA
BH
VV01 code 10 and shuttle valve code CA
and position control
3)
with amplifier
BK
VV01 code 12 and shuttle valve code CA
and position control
3)
with amplifier
BN
VV01 code 10 and shuttle valve code DA
and position control
3)
with amplifier
BQ
VV01 code 12 and shuttle valve code DA
and position control
3)
with amplifier
BC VV01 code 10 and position control
3)
with amplifier
BE VV01 code 12 and position control
3)
with amplifier
BA Position control
3)
with amplifier
BF
Position control
3)
with amplifier
and shuttle valve code CA
BL
Position control
3)
with amplifier
and shuttle valve code DA
Pilot
cap
Pilot body
configuration
Code Body Ports X Y Z X-Y X1 Y1
VV01
Standard
1
2-/3-port
Pilot oil = pilot drain — —
2
2-/3-port
Pilot oil = pilot drain — —
3
2-port
Pilot oil = pilot drain —
With solenoid valve (VV01)
4
2-/3-port
Internal to B —
5
2-port
Internal to B
6
2-/3-port
Ext. out of cap —
7
2-port
Ext. out of cap
With stroke limiter (not for D5S06)
A
2-/3-port
Pilot oil = pilot drain — — —
B
2-/3-port
Pilot oil = pilot drain — — — —
C
2-port
Pilot oil = pilot drain — — —
open bore closed bore orifice Ø 1.2
Code Size Poppet type Sleeve
1
06,
08,10,12
With closed bottom and 15° chamfer
(pZ max. = pA +20bar
1
2
06
With 0.8 dia. orifice at the bottom and 15°chamfer 1
08, 10
With 1.2 dia. orifice at the bottom and 15°chamfer 1
4
06,
08,10,12
With closed bottom and 45° chamfer 1, 3
A
2)
08, 10, 12
Safety spool (for end position control only) 3
B
2)
08, 10, 12
Throttle spool, 10° chamfer 3
C
2)
08, 10, 12
Throttle spool, 3° chamfer
3
Code Seals
1 NBR
5 FPM
3)
Position control for D5S08/10 only.
Spring 2 or 4. Spool A and sleeve 3.
OptionsSpring
Code
Spring (approx. cracking pressure [bar])
Sleeve Code 1 Sleeve Code 3
A -> B A -> B B -> A
D5S06 D5S08/12 D5S06 D5S08/12 D5S06 D5S08/12
1 2.8 3.5 6.5 6.5 9.5 11.0
2 0.5 0.5 1.0 1.0 1.5 1.7
3 0.3 0.3 0.6 0.6 0.9 1.0
4 2.2 2.2 4.0 3.5 5.5 6.0
5 — 9.0 — 16.0 — 28.0
6 1.2 1.2 2.0 2.2 3.0 3.8
7 3.0 — 8.0 — 12.0 —
1)
D5S 3-port only
4)
To be used in combination with rectifier
plugs at 120VAC / 230VAC power supply.
Code
Solenoid voltage
omit Standard w/o vent function
G0R 12V=
G0Q 24V=
GAR
4)
98V=
GAG
4)
205V=
W30 110V / 50Hz ; 120V / 60Hz
W31 230V / 50Hz ; 240V / 60Hz
Examples see end of chapter.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-37
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
Electrical (solenoid)
Duty ratio [%] 100
Response time [ms] Energized / De-energized AC: 20/18 , DC: 46/27
Code
G0R G0Q GAR GAG W30 W31
Supply voltage [V]
12V = 24V = 98V = 205V =
110 at 50Hz
120 at 60Hz
230 at 50Hz
240 at 60Hz
Tolerance supply voltage [%]
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
Power consumption hold [W]
31 31 31 31 78 78
in rush [W]
31 31 31 31 264 264
Max. switching frequency AC: up to 7200, DC: up to 16000 switchings/hour
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Coil insulation class H (180 °C)
General
Size 06 08 10 12
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTF
D
value [years] 150
Weight D5S 2port [kg] 3.6 4.1 5.4 —
D5S 3port [kg] 3.4 4.4 5.0 7.8
Hydraulic
Max. operating pressure [bar]
SAE61 Ports A, B 350 350 280 210
Port Y1 30 30 30 30
Nominal flow [l/min] 180 360 600 800
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [°C] -20...+80
Viscosity permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Technical Data
Technical data
D5S pilot configuration
3-port 2-port: Seat Entry 2-port: Annular Entry
Standard
with vent valve VV01 VV01
VV01
X Z Y
Y1
X-Y
A
A
Z1
B
X1
AB
AA
AZ
X Z Y
Y1
X-Y
VV01
A
B
X1
Z1
AB
AA
AZ
VV01
X Z Y
Y1
X-Y
A
B
X1
Z1
AB
AA
AZ
Z Y
Z1
de-energized: open
de-energized: closed
Z Y
Z1
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-38
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
Characteristic Curves / Cartridges
D5S 2-port Leakage
D5S 3-port
Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C
A
Z
B
A
Z
B
A
Z
B
A
Z
B
A
Z
B
A
Z
B
1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.67 1 : 1.67 1 : 1.67
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
15° chamfer 15° chamfer 45° chamfer 45° chamfer 45° chamfer 45° chamfer
orifice safety spool throttle spool
Selection of Cartridges
All characteristic curves measured with HLP46 at 50°C.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-39
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
D5S 2-port
Seat entry Annular entry
Dimensions
Ports Function
Port size
D5S06 D5S08 D5S10
A Inlet or outlet ¾" SAE-61 1" SAE-61 1¼" SAE-61
B Outlet or inlet ¾" SAE-61 1" SAE-61 1¼" SAE-61
X1 External pilot port
G¼"
Y1 External pilot drain
NG l1 l2 l3 b1 h1 h2 h3 h4 d1 d2
06 77 101.0 22.2 60 37 47.6 90 127.6 19 10.5
08 94 120.5 26.2 60 45 52.4 96 133.6 25 10.5
10 94 128.0 30.2 75 48 58.7 109 146.6 32 12.5
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-40
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
Dimensions D5S 3-port
Ports Function
Port size
D5S06 D5S08 D5S10 D5S12
A (2x) Inlet or outlet ¾" SAE-61 1" SAE-61 1¼" SAE-61 1½" SAE-61
B Outlet or inlet ¾" SAE-61 1" SAE-61 1¼" SAE-61 1½" SAE-61
X1
1)
External pilot port
G¼"Y1 External pilot drain
M Pressure gauge
NG l1 l2 l3 l4 b1 b2 h1 h2 h3 h4 h5 h6 d1 t1 d2 d3
06 49 47.6 56 63 22.2 60 41 47.6 29.5 22.2 82 119 3/8" UNC 20 19 10.5
08 55 52.4 58 65 26.2 60 47 52.4 30.5 26.2 103 141 3/8" UNC 23 25 10.5
10 57 58.7 64 61 30.2 75 65 58.7 37.5 30.2 113 150 7/16" UNC 22 32 12.5
12 37 69.8 55 93 35.7 80 73 69.8 35.5 35.7 140 178 1/2" UNC 27 38 13.5
Dimensions
1)
closed when supplied
Seal kits
NG NBR FPM
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-41
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
Example pilot oil external from X1, pilot drain internal out of B
Function
Solenoid de-energized:
pilot oil from X1 to Z blocks the connection
from A to B or B to A.
Solenoid energized:
pilot pressure from X1 is blocked in the VV01.
The oil in Z is internally drained to port B. Al-
lowing flow from A to B, while B to A remains
blocked.
D5S with VV01 dimensions
D5S with Vent Valve
Seal kits
NBR FPM
DC solenoid
S26-58515-0 S26-58515-5
AC solenoid
S26-35237-0 S26-35237-5
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-42
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
D5S with position control
Position control by proximity switch (incl. amplifier). Valve open: proximity switch activated. This proximity switch is
pressure proof and has no wearing parts.
Note: Position control for D5S08 and D5S10 only.
D5S with position control dimensions
Function PNP, contact
Supply voltage (Us) [VDC] 10...30
Supply voltage ripple [%] £ 10
Current consumption [mA] max. 8
Residual voltage L-signal [V] Us - 2.2 at l
max
Output current (I) [mA] £ 200
Protection class IP67
Ambient temperature [C°] -25...+70
Wire cross section [mm
2
] 3 x 0.5
D5S with Position Control
Example D5S 2 port
Technical data (proximity switch)
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-43
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
D5S stroke limiter
D5S with shuttle valve
Dimensions
D5S with Stroke Limiter
Example:
D5S08-54A...
D5S10-54A...
D5S12-54A...
X1 = external pilot-oil (optional)
Note:
Stroke limiter not for use with D5S06, solenoid valve VV01, shuttle
valve and position control.
Shuttle valve only in connection with vent valve VV01.
Stroke limiter dimensions
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-44
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
D5S 2-port
Seat entry Annular entry
D5S 3-port Stroke limiter D5S 3-port
Ordering Code Explanation (Examples)
Stroke limiter D5S 2-port
Seat entry Annular entry
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-45
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
Ordering Code Explanation (Examples)
D5S 2-port with solenoid valve VV01
Seat entry Annular entry
D5S 2-port with with solenoid valve VV01 and shuttle valve
Seat entry Annular entry
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-46
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
Ordering Code Explanation (Examples)
D5S 3-port with solenoid valve VV01
D5S 3-port with with solenoid valve VV01 and shuttle valve
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-47
Directional Seat Valve
Series D5S
D5S UK.INDD CM 07.09.11
Ordering Code Explanation (Examples)
D5S 2-port position control
Seat entry Annular entry
Seat entry Annular entry
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-48
D5S UK.INDD CM 07.09.11
Directional Seat Valve
Series D5S
Ordering Code Explanation (Examples)
D5S 3-port position control
Seat entry Annular entry
Seat entry Annular entry