D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A223
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Technical Information
General Description
Series D4S seat valves are designed for directional
control functions. A large variety of poppets, springs
and covers - including shuttle valves, stroke limiters,
solenoid valves (VV01) and position control - allow to
design individual hydraulic solutions for nominal flow
up to 600 LPM (158.7 GPM).
A complete program is offered under the Parker brand:
subplate mounted valves (D4S ), SAE flange valves
(D5S), pipe mounted valves (D4S), slip-in
cartridges (CAR - on request).
Features
•
Subplate mounting acc. to ISO 5781.
•
Leak-free seat valve design.
•
Numerous pilot options.
•
6 poppet types.
•
3 sizes (NG10, 25, 32).
All characteristic curves measured with HLP46 at 50°C.
Performance Curves
Sleeve 1,Poppet 1 Sleeve 1, Poppet 2 Sleeve 1, Poppet 4 Sleeve 3, Poppet 4 Sleeve 3, Poppet A Sleeve 3, Poppet B/C
1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.67 1 : 1.67 1 : 1.67
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.95 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
A
= 0.6 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.05 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
A
B
= 0.4 A
C
15° chamfer 15° chamfer 45° chamfer 45° chamfer 45° chamfer 45° chamfer
orifice safety spool throttle spool
Selection of Cartridges
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A224
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Ordering Information
Seat
Valve
Pilot
Connection
Nominal
Size
D4S
Subplate
Mounting
ISO 6264,
Y1 Port G1/4"
Cap
Version
Sleeve
Code Description
1 AA=95%,
AB=5%
3 AA=60%,
AB=40%
Spool
Type
9
Code Description
03 NG10
06 NG25
10 NG32
Code Size Poppet Type Sleeve
1 03, 06, 10 With closed bottom and 15° chamfer
(pZ max. = pA +20 Bar (290 PSI)
1
2 03 With 0.8 dia. orifice at the bottom
and 15° chamfer
1
06, 10 With 1.2 dia. orifice at the bottom
and 15° chamfer
1
4 03, 06, 10 With closed bottom and 45° chamfer 1, 3
A* 06, 10 Safety spool
(for end position control only)
3
B* 06, 10 Throttle spool, 10° chamfer 3
C* 06, 10 Throttle spool, 3° chamfer 3
* Springs 2, 3 and 6 only.
Code Pilot Oil Line in Body
A-X B-Y
1
Internal from A
2
External from X
A
1)
Internal from A
B
1)
External from X
C
Internal from A + B
D
Internal from B
G
External from Y
1)
With VV01 only.
Code Ports X Y Z X-Y Y1
VV01
Standard
1 Pilot Oil = Pilot Drain
—
C Pilot Oil = Pilot Drain
—
With Solenoid Valve (VV01)
2 External PD from cap
5 External to subplate
6 Internal pilot drain
With Stroke Limiter (not for D4S03)
3 Pilot Oil = Pilot Drain
— — — —
4 Pilot Oil = Pilot Drain
— — — —
Key: Open Bore Closed Bore Orifice ∅ 1.2
Note: Combination examples provided on pages A227-A229.
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A225
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Ordering Information
Design
Series
B
Seal
Code Description
1 Nitrile
5 Fluorocarbon
OptionsSwitching
Type
Spring
Code Description
Omit Standard
013 Cover for
End Position
Control
Code
Spring — Approx. Cracking Pressure in Bar (PSI)
Sleeve Code 1 Sleeve Code 3
A -> B A -> B B -> A
D4S03 D4S06/10 D4S03 D4S06/10 D4S03 D4S06/10
1 2.8 (40.6) 3.5 (50.8) 6.5 (94.3) 6.5 (94.3) 9.5 (137.8) 11.0 (159.5)
2 0.5 (7.3) 0.5 (7.3) 1.0 (14.5) 1.0 (14.5) 1.5 (21.8) 1.7 (24.7)
3 0.3 (4.4) 0.3 (4.4) 0.6 (8.7) 0.6 (8.7) 0.9 (13.1) 1.0 (14.5)
4 2.2 (31.9) 2.2 (31.9) 4.0 (58.0) 3.5 (50.8) 5.5 (79.8) 6.0 (87.0)
5 – 9.0 (130.5) – 16.0 (232.0) – 28.0 (406.0)
6 1.2 (17.4) 1.2 (17.4) 2.0 (29.0) 2.2 (31.9) 3.0 (43.5) 3.8 (55.1)
7 3.0 (43.5) – 8.0 (116.0) – 12.0 (174.0) –
Code Description
Omit Standard without Vent Function
09 VV01 with Manual Override De-energized;
power comp. open
10 VV01 without Manual Override
11 VV01 with Manual Override De-energized;
power comp. closed
12 VV01 without Manual Override
CA Shuttle Valve
DA Shuttle Valve
CB VV01 Code 09 and Shuttle Valve Code CA
CD VV01 Code 11 and Shuttle Valve Code CA
DB VV01 Code 09 and Shuttle Valve Code DA
DD VV01 Code 11 and Shuttle Valve Code DA
BH VV01 Code 10 and Shuttle Valve Code CA and
Position Control* with Amplifier
BK VV01 Code 12 and Shuttle Valve Code CA and
Position Control* with Amplifier
BN VV01 Code 10 and Shuttle Valve Code DA and
Position Control* with Amplifier
BQ VV01 Code 12 and Shuttle Valve Code DA and
Position Control* with Amplifier
BC VV01 Code 10 and Position Control* with Amplifier
BE VV01 Code 12 and Position Control* with Amplifier
BA Position Control* with Amplifier
BF Position Control* with Amplifier and Shuttle Valve
Code CA
BL Position Control* with Amplifier and Shuttle Valve
Code DA
* Position control for D4S06/10 only.
Spring 2 or 4. Spool A and sleeve 3.
Valve open: Proximity Switch damped.
Solenoid
Voltage
Code Description
Omit Standard w/o vent function
G0R 12V
G0Q 24V
GAR 98V
GAG 205V
W30 110V 50Hz / 120V 60Hz
W31 230V 50Hz / 240V 60Hz
Weight:
D4S03 2.7 kg (6.0 lbs
D4S06 4.5 kg (9.9 lbs)
D4S10 6.0 kg (13.2 lbs)
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A226
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Technical Information
Electrical (Solenoid)
Duty Ratio
100%
Response Time
Energized / De-energized AC 20/18 ms, DC 46/27 ms
Protection Class
IP65 in accordance with EN60529 (plugged and mounted)
Code G0R G0Q GAR GAG W30 W31
Supply Voltage
12V 24V 98V 205V 110V at 50Hz/
120V at 60 Hz
220V at 50Hz/
240V at 60Hz
Tolerance Supply Voltage
+5 to -10 +5 to -10 +5 to -10 +5 to -10 +5 to -10 +5 to -10
Power Consumption, Hold [W]
31 31 31 31 78 78
Power Consumption, In Rush [W]
31 31 31 31 264 264
Max. Switching Frequency [1/h]
AC up to 7200; DC up to 16,000 switchings/hour
Solenoid Connection
Connector as per EN175301-803
Protection Class
IP65 in accordance with EN 60529 (plugged and mounted)
Coil Insulation Class
H (180°C) (356°F)
Specifications
General
Size 03 06 10
Mounting
Subplate according to ISO 6264
Mounting Position
Unrestricted
Ambient Temperature Range
-20°C to +50°C (-4°F to +122°F)
MTTFD
150 years
Hydraulic
Maximum Operating
Pressure
Ports A, B
up to 350 Bar
(5075 PSI)
up to 350 Bar
(5075 PSI)
up to 350 Bar
(5075 PSI)
Port Y
with VV01
140 Bar
(2030 PSI)
140 Bar
(2030 PSI)
140 Bar
(2030 PSI)
Nominal Flow
180 LPM
(47.6 GPM)
360 LPM
(95.2 GPM)
600 LPM
(158.7 GPM)
Fluid
Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature
-20°C to +80°C (-4°F to +176°F)
Viscosity Permitted
Recommended
10 to 650 cSt / mm
2
/s (46 to 3013 SSU)
30 cSt / mm²/s (139 SSU)
Filtration
ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
D4S Pilot Configuration
D4S Direct Operated D4S with VV01
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A227
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Ordering Information
D4S Direct Operated Examples
D4S with VV01 Examples
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A228
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Ordering Information
D4S with VV01 Examples
D4S with Shuttle Valve Examples
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A229
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Ordering Information
D4S with Position Control Examples
D4S with Stroke Limiter Examples
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A230
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Dimensions
NG ISO-code X1 X2 X3 X4 X5 X6 X7 Y1 Y2 Y3 Y4
10 6264-06-09-*-97
42.9
(1.69)
35.8
(1.41)
21.5
(0.85)
-
7.2
(0.28)
21.5
(0.85)
31.8
(1.25)
66.7
(2.63)
58.8
(2.31)
33.4
(1.31)
7.9
(0.31)
25 6264-08-13-*-97
60.3
(2.37)
49.2
(1.94)
39.7
(1.56)
-
11.1
(0.44)
20.6
(0.81)
44.5
(1.75)
79.4
(3.13)
73.0
(2.87)
39.7
(1.56)
6.4
(0.25)
32 6264-10-17-*-97
84.2
(3.31)
67.5
(2.66)
59.5
(2.34)
42.1
(1.66)
16.7
(0.66)
24.6
(0.97)
62.7
(2.47)
96.8
(3.81)
92.8
(3.65)
48.4
(1.91)
3.8
(0.15)
NG ISO-code B1 B2 H1 H2 H3 L1 L2 D1 D2 D3 t1 D4 t2 D5 D6
10 6264-06-09-*-97
87.3
(3.44)
33.35
(1.31)
83.0
(3.27)
21.0
(0.83)
45.0
(1.77)
29.0
(1.14)
94.8
(3.73)
15.0
(0.59)
7.0
(0.28)
7.1
(0.28)
8.0
(0.31)
M10
16.0
(0.63)
10.8
(0.43)
17.0
(0.67)
25 6264-08-13-*-97
105.0
(4.13)
39.7
(1.56)
109.5
(4.31)
29.0
(1.14)
71.5
(2.81)
34.7
(1.37)
126.8
(4.99)
23.4
(0.92)
7.1
(0.28)
7.1
(0.28)
8.0
(0.31)
M10
18.0
(0.71)
110.8
(0.43)
17.0
(0.67)
32 6264-10-17-*-97
120.0
(4.72)
48.4
(1.91)
120.0
(4.72)
29.0
(1.14)
82.0
(3.23)
30.6
(1.20)
144.3
(5.68)
32.0
(1.26)
7.1
(0.28)
7.1
(0.28)
8.0
(0.31)
M10
20.0
(0.79)
10.8
(0.43)
17.0
(0.67)
NG ISO-code Bolt Kit Surface Finish
Nitrile Fluorocarbon
10 6264-06-07-*-97 BK 505 4x M10 x 35 DIN 912 12.9 63 Nm S26-58507-0 S26-58507-5
25 6264-08-11-*-97 BK 485 4x M10 x 45 DIN 912 12.9 (46.5 lb.-ft.) S26-58475-0 S26-58475-5
32 6264-10-15-*-97 BK 506 6x M10 x 45 DIN 912 12.9 ±15% S26-58508-0 S26-58508-5
Inch equivalents for millimeter dimensions are shown in (**)
Seal
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A231
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Dimensions
D4S with VV01
Dimensions in brackets [ ] are for version VV01with
shuttle valve code DB or DD.
Note: Shuttle valves only use in connection with vent valve VV01.
D4S with Shuttle Valve
Inch equivalents for millimeter dimensions are shown in (**)
VV01 Seal Kits
Nitrile Fluorocarbon
DC Solenoid
S26-58515-0 S26-58515-5
AC Solenoid
S26-35237-0 S26-35237-5
D4S.indd, dd
Directional Seat Valves
Catalog HY14-2500/US
Series D4S
A232
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Dimensions
Dimensions D4S Stroke Limiter
Dimensions D4S Position Control
Function PNP, contact
Supply voltage (Us) [VDC]
10...30
Supply voltage ripple [%]
≤ 10
Current consumption [mA]
max. 8
Residual voltage L-signal [V]
Us - 2.2 at l
max
Output current (I) [mA]
≤ 200
Protection class
IP67
Ambient temperature [C°]
-25...+70; (-13°F...+158° F)
Wire cross section [mm
2
]
3 x 0.5
Technical Information (proximity switch)
Position Control by Proximity Switch (incl. Amplifier)
Valve open: proximity switch activated.
This proximity switch is pressure proof and has no wearing
parts.
Note: Position control for D4S06 and D4S10 only.
Note: Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control.
Inch equivalents for millimeter dimensions are shown in (**)