3-87
Direct Operated Proportional DC Valve
Series D3FP
D3FP UK.INDD RH 12.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Characteristics
The direct operated control valve D3FP of the nominal
size NG10 (CETOP05) shows extremly high dynamics
combined with high flow. First of all it is used for highest
accuracy in positioning of hydraulic axis and controlling
of pressure and velocity.
Driven by the new patented VCD
®
actuator the D3FP
reaches the frequency response of real servovalves.
At power-down the spool moves in a defined position. All
common input signals are available.
Technical features
• Real servovalve dynamics
(-3dB/350Hz at ±5% input signal)
• Max. tank pressure 350 bar
(with external drain port Y)
• Defined spool positioning at power-down - optional
P-A/B-T or P-B/A-T or center position
(for overlapped spools)
• Onboard electronics
• Spool / sleeve design
3-88
D3FP UK.INDD RH 12.08.2011
Direct Operated Proportional DC Valve
Series D3FP
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Ordering Code
Direct.
control
valve
Spool
position
on power
down
1)
Command-
signal
Acces-
sories
Please order connector separately.
See chapter 3 accessories.
Spool
type
Design
series
(not required
for ordering)
Seals
Code Signal Function
B +/- 10V 0...+10V -> P-A
E +/- 20mA 0...+20mA -> P-A
S 4...20mA 12...20mA -> P-A
Size
DIN NG10
CETOP05
NFPA D05
Y-port
(plugged)
4)
1)
On power down the spool moves in a defined position. This cannot
be guaranteed in case of single flow path on the control edge A – T
resp. B – T with pressure drops above 120 bar or contamination in
the hydraulic fluid.
2)
approx. 10% opening, only zerolapped spools and underlapped
spools.
3)
only for overlapped spools
4)
needs to be removed at tank pressure >35 bar
Proportional
control
VCD Spool/
sleeve
design
Code Seals
N NBR
V FPM
H for HFC fluid
Code Spool pos. at power down
A
2)
B
2)
C
3)
Code Spool type
Flow [l/min]
at ∆p 35bar
per metering edge
Zerolap
E50Y 100
E50P 50
B60Y 100
B60P 50
Underlap approx. -0.5%
E55Y 100
E55P 50
Overlap 18%
E01Y
E01P
100
50
E02Y
E02P
100
50
B31Y
B31P
100 / 50
50 / 25
B32Y
B32P
100 / 50
50 / 25
Q
B
= Q
A
/2
Q
B
= Q
A
/2
Q
B
= Q
A
/2
Q
B
= Q
A
/2
PF3D 9 0
Code Connection type
0 6 + PE acc. EN175201-804
5 11 + PE acc. EN175201-804
7 6 + PE + Enable
3-89
Direct Operated Proportional DC Valve
Series D3FP
D3FP UK.INDD RH 12.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Technical Data
General
Design Direct operated proportional DC valve
Actuation VCD
®
actuator
Size NG10/CETOP05/NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+50
MTTF
D
value [years] 75
Weight [kg] 6.5
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure
[bar]
[bar]
Ports P, A, B 350
Port T max. 35, port Y max. 35
1)
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+60
Viscosity permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
20...380
30...80
Filtration ISO 4406 (1999) 18/16/13 (meet NAS 1638: 7)
Flow nominal
at ∆p=35bar per control edge
2)
[l/min] 50 / 100
Flow maximum [l/min] 150
Leakage at 100 bar [ml/min] <400 (Zerolap spool); <100 (Overlap spool)
Static / Dynamic
Step response at 100% step
3)
[ms] <6
Frequency response (±5% signal)
3)
[Hz] 200 (amplitude ratio -3dB), 200 (phase lag -90°)
Hysteresis [%] <0.05
Sensitivity [%] <0.03
Temperature drift [%/K] <0.025
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple [V] 22 ... 30, ripple <5% eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 medium lag
Input signal
Voltage
Impedance
Current
Impedance
Current
Impedance
[V]
[kOhm]
[mA]
[Ohm]
[mA]
[Ohm]
10...0...-10, ripple <0.01% eff., surge free, 0...+10V P->A
100
20...0...-20, ripple <0.01% eff., surge free, 0...+20mA P->A
250
4...12...20, ripple <0.01% eff., surge free, 12...20mA P->A
<3.6 mA = disable, >3.8 mA = according to NAMUR NE43
250
Differential input max.
Code 0
Code 5
Code 7
[V]
[V]
[V]
30 for terminal D and E against PE (terminal G)
30 for terminal 4 and 5 against PE (terminal W )
30 for terminal D and E against PE (terminal G)
Enable signal (only code 5/7) [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] +10...0...-10 / +Ub, rated max. 5mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection
Code 0/7
Code 5
6 + PE acc. EN 175201-804
11 + PE acc. EN 175201-804
Wiring min. Code 0/7
Code 5
[mm²]
[mm²]
7 x 1.0 (AWG 18) overall braid shield
8 x 1.0 (AWG 18) overall braid shield
Wiring lenght max. [m] 50
1)
For applications with p
T
>35 bar the Y-port has to be connected and the plug in the Y-port has to be removed.
2)
Flow rate for different ∆p per control edge:
3)
Measured with load (100 bar pressure drop/two control edges)
Q
x
= Q
Nom.
·
√
∆p
x
∆p
Nom.
3-90
D3FP UK.INDD RH 12.08.2011
Direct Operated Proportional DC Valve
Series D3FP
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Characteristic Curves
Frequency response
±5% command signal
±90% command signal
Pressure gain
Flow curves
at ∆p = 35 bar per metering edge
Spool type E50/E55, E01/E02
* When exceeding the functional limits, for a period of time the
valve will go into fail safe and power supply needs to be switched
off/on to re-enable the valve.
Command signal [%]
Flow
100%=Q
Nom.
75
50
25
0
P-B
A-T
P-A
B-T
-100 -80 -60 -40 -20 0 20 40 60 80 100
E50/E55
E01/E02
Functional limits*
at 25%, 50%, 75% and 100% command signal
Spool type E01/E02
Functional limits*
at 25%, 50%, 75% and 100% command signal
Spool type E50/E55
A B
P T
100%
75%
50%
25%
Flow Q [l/min]
0
150 3000
Pressure drop p P-T [bar]
75 225
150
120
90
60
30
180
210
25 50 100 125 175 200 250 275
A B
P T
100%
75%
50%
25%
Flow Q [l/min]
0
150 3000
Pressure drop p P-T [bar]
75 225
150
120
90
60
30
180
210
25 50 100 125 175 200 250 275
3-91
Direct Operated Proportional DC Valve
Series D3FP
D3FP UK.INDD RH 12.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Block Diagrams
Code 7
6 + PE + Enable
Code 0 Code 5
6 + PE 11 + PE
3-92
D3FP UK.INDD RH 12.08.2011
Direct Operated Proportional DC Valve
Series D3FP
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
X
T T
BA
P
Y
245.2
69.6
159
30
48
147
1)
A B
41.7 203.5
Ø11
Ø6.8
Surface finish
BK385
4xM6x40
DIN 912 12.9
13.2 Nm
±15%
NBR: SK-D3FP
FPM: SK-D3FP-V
HFC: SK-D3FP-H
1)
O-ring recess diameter on valve body.
Dimensions