Hydraulics
11
11
1
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio 44035 USA
Proportional Directional Control Valves
Bulletin 2562-M1/USA
d31fs.p65, dd, fm
Series D31FSTechnical Information
NOTE: Positive (+) voltage com-
mand energizes solenoid B which
produces valve flow P→B, A→T.
Negative (–) command energizes
solenoid A which produces valve
flow P→A, B→T.
PILOT AND DRAIN CONFIGURATIONS
Pilot 13 Drain 14
Code Qty Part Number Pilot Qty Part Number Drain
1 — Internal 1 5000471 (M6 x 6) External
2 1 5000471 (M6 x 6) External 1 5000471 (M6 x 6) External
4 — Internal — — Internal
5 1 5000471 (M6 x 6) External — — Internal
M6
M6
10
9
11
1
5
1
1
8
3
6
2
7
1 1 D1FVE02BCVXP20 Pilot Valve
2 1 692915 Hirschmann Plug (gray)
3 1 692914 Hirschmann Plug (black)
5 1 1210503 LVDT Assembly w/ plug
6 4 M5 x 30 Pilot Valve Mtg. Bolt
REPAIR PARTS
7 2 45051416 Spool Centering Spring
8 4 2012*-9 O-Ring 2-012N552-90
9 5 2014*-9 O-Ring 2-014N552-90
10 2 2119*-9 O-Ring 2-119N552-90
12 2 2013*-9 O-Ring 2-013N552-90 (below)
Item Qty Part Number DescriptionItem Qty Part Number Description