18.10
47
Ordering code
Pressure [bar]
Flow [l/min]
47
350
180 - 350
3
80 - 210
2
37
210
3,5:1
8:1
Setting range
[bar]
Pressure Increase
[bar/turn]
Standard setting
4 l/min [bar]
SPRINGS
PILOT RATIO
Cartridge SAE 10
NOT COMPENSATED COUNTERBALANCE VALVE
• Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 l/min
• Max working pressure. . . . . . . . . . . . . . . . . . . 350 bar
• Compensation. . . . . . . . . . . . . . . . Not compensated
• Cartridge tightening torque. . . . . . . . . . . . . . . 50-55 Nm
• Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm
• Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,3 Kg
• Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-predisposed
• Cavity . . . . . . . . . . . . . . . . . . . C331000 page 221
• Body single cavity. . . . . . . . . . . . 172312 page 193
• Body double cavity . . . . . . . . . . . 176312 page 194
0 6 1 3 0 0 0
8
3
0613.0
0 10 20 30 40 50 60 70
10
15
20
25
30
35
0
5
1 2
2
1
Note
-Setting: 1,3 times the maximum load induced pressure.
-The back pressure (2) may affect the relief function
(for circuits with back pressure use 0613.1 or 0613.2).
TAMPER PROOF OPTION
PRE-ARRANGED
NOT PRE-ARRANGED
0
2
21
3
48 55 max
17,4
19
26,8
7/8-14 UNF-2A
4,5
Hex.5
Hex.24
3
2
1
70,5
118,5
Hex.17