HPCV16
hydraforce.com
HIGH PRESSURE PILOT OPERATED CHECK VALVE
Overview
Symbol
Description
The HPCV16 is a high pressure pilot operated, hydraulic check valve for
use in blocking or load holding circuits
Operation
The valve allows flow from port "b" to port "a", while normally blocking
flow in the opposite direction. Flow will be allowed from "a" to "b" when
pressure is applied to port "x". The valve has 2.3:1 pilot ratio, so at least
44% of the load pressure held at port "a" is required at port "x" to open
the valve
Features
Hardened seat for long life and low leakage.
❍
Optional sealed pilot piston.
❍
Optional spring ranges.
❍
Check section is serviceable as a cartridge.
❍
All HyPerformance products are tested to the rigorous standards of
the NFPA specification T2.6.1.
❍
All HyPerformance valves are tested at a verification level of 90%
and an assurance of 99%.
❍
Ratings
Pressure Ratings
Pressure rating
350 bar
420 bar (5075 psi)
6090 psi - Note: 10% cycle life
Proof pressure
689 bar (10000 psi)
Burst pressure
1379 bar (20000 psi)
Pilot ratio
2.3:1
Flow Ratings
Flow rating
151 lpm (40 gpm)
Maximum internal leakage
5 drops/min - Note: Port A to b, at 350 bar (5075 psi)
200 ml/min - Note: Port x to b, at 34.5 bar (500 psi)
1.5 lpm (0.4 gpm) - Note: Port x to b, at 350 bar (5075 psi)
hydraforce.com
10/12/2020
HPCV16