FLOW CONTROLS
EC12-30 Pressure Compensator
DESCRIPTION
A screw-in, cartridge-style pressure-compensating element, intended for use with a
remote fi xed or variable orifi ce to yield a two-port-type, pressure-compensated, fl ow-
regulating hydraulic valve.
OPERATION
The EC12-30 maintains a constant fl ow rate from ➁ regardless of load pressure
changes in the circuit downstream of
➁.
The cartridge maintains a constant differential pressure from circuit point P to port
➀ (see USASI Symbol), thereby regulating the hydraulic fl ow rate between the two
points in the circuit.
FEATURES
• Hardened parts for long life.
• Quiet, modulated response.
• Industry common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Regulated Flow Rate: 58 lpm (15 gpm) max.
Standard Compensator Bias Spring: 6.9 bar (100 psi) See note on Ordering Table.
Flow Maintenance: ±10% from 0.38 to 58 lpm (0.1 to 15 gpm) at pressures from
5.5 to 207 bar (80 to 3000 psi)
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC12-3; See page 9.112.1
Cavity Tool: CT12-3XX; See page 8.600.1
Seal Kit: SK12-3X-MM; See page 8.650.1
USASI: ISO:
SYMBOLS
PERFORMANCE
(Cartridge Only)
5.410.1
8.1/0.32
7.1/0.28
6.1/0.24
5.1/0.20
4.1/0.16
ORIFICE DIAMETER mm/inch
Output Flow vs. Orifice Dia.
with 100 psid Spring
32 cSt/150 ssu oil at 40°C
18.9
5
FLOW lpm/gpm
37.9
10
3.0/0.12
56.8
15
2.0/0.08
1.0/0.04
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
Cartridge: Weight: 0.23 kg. (0.50 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Buna N O-rings and polyester
elastomer back-ups standard.
Standard Ported Body: Weight:
1.13 kg. (2.5 lbs.) Anodized high-
strength 6061 T6 aluminum alloy,
rated to 207 bar (3000 psi). Ductile
iron bodies available; dimensions
may differ. See page 8.012.1
DIMENSIONS
MATERIALS
TO ORDER
Porting
Cartridge Only 0
SAE 8 8T
SAE 10 10T
SAE 12 12T
1/2 in. BSP* 4B
3/4 in. BSP* 6B
*BSP Body; U.K. Mfr. Only
EC12-30
5.410.2
EC12-30 - __ __ __ - __ - __
Compensator Spring
100 6.9 bar (100 psid) standard
160 11.0 bar (160 psid)
Seals
N Buna N (Std.)
V Fluorocarbon
®
HYDRAFORCE
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.