DIRECTIONAL VALVES
LS50-30 Load Shuttle, Ball-Type
DESCRIPTION
A load-shuttling, screw-in, cartridge-style hydraulic check valve, for use in blocking
circuits where a priority of fl ow/direction is given to a higher pressure circuit over a
lower one.
OPERATION
The LS50-30 will allow fl ow from the higher pressure ➀ or ➂ port to the ➁ port.
The valve is commonly used to direct oil from the pressure side of a bidirectional
hydraulic motor to a pressure-released hydraulic brake.
FEATURES
• Rapid response to load direction changes.
• Industry common cavity.
RATINGS
Operating Pressure: 345 bar (5000 psi)
Proof Pressure: 390 bar (5700 psi)
Flow: See Performance Chart
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. at 345 bar(5000 psi)
Temperature: -40 to 120°C with standard Polyurethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-3; See page 9.110.1
Cavity Tool: CT10-3XX; See page 8.600.1
Seal Kit: SK10-3P-MM; See page 8.650.1
SYMBOLS
USASI/ISO:
PERFORMANCE (Cartridge Only)
4.272.1
17.2/250
13.8/200
10.3/150
6.9/100
3.4/50
3.8
1
11.4
3
FLOW lpm/gpm
PRESSURE DROP bar/psi
7.5
2
15.1
4
18.9
5
22.7
6
26.5
7
30.2
8
or to
32 cSt/150 ssu oil at 40°C
➀➂➁
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.