DIRECTIONAL VALVES
CV16-20 Check Valve
DESCRIPTION
A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding
device.
OPERATION
The CV16-20 allows fl ow from ➀ to ➁, while blocking oil fl ow in the opposite direction.
The cartridge has a fully guided poppet which is spring-biased to closed until suffi -
cient pressure is applied at
➀ to open to ➁.
FEATURES
• Hardened seat for long life and low leakage.
• Optional bias springs for back-pressure application fl exibility.
• Industry common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Proof Pressure: 350 bar (5075 psi)
Flow: See Performance Chart
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. at 240 bar (3500 psi)
Crack Pressure Defi ned: Gauge pressure evident at
➀ at 0.95 lpm (0.25 gpm)
attained
Standard Bias Springs at Crack: 0.35 bar (5 psi); 1.7 bar (25 psi); 4.1 bar (60 psi)
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-2; See page 9.116.1
Cavity Tool: CT16-2XX; See page 8.600.1
Seal Kit: SK16-2X-T; See page 8.650.1
USASI: ISO:
PERFORMANCE (Cartridge Only)
SYMBOLS
4.014.1
5.5/80
4.1/60
2.8/40
1.4/20
37.9
10
75.8
20
113.6
30
FLOW lpm/gpm
PRESSURE DROP bar/psi
151.4
40
to : 0.34 bar/5 psi spring — ;
1.72 bar/25 psi spring - - -
32 cSt/150 ssu oil at 40°C
➀➁
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.