DESCRIPTION
A solenoid-operated, normally-closed, on/off, poppet-type, screw-in hydraulic
cartridge valve incorporating an integral load-sense pressure port with isolation check.
OPERATION
When de-energized, the SVCL10-32 blocks flow at ports 3 and 1. When energized,
flow is allowed from 3 to 1 and 2 with a check-isolated load sense signal supplied at
2. Reverse flow is not allowed from 1 to 3.
NOTE: When using this valve in bridge circuits, seals should not be used on the pilot
pistons of the pilot-operated check valves. This is to avoid trapping oil which would
keep the pilot-operated check valve open.
FEATURES
• Continuous-duty rated solenoid.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• All ports may be fully pressurized.
• Cartridges are voltage interchangeable.
• Optional waterproof E-Coils rated up to IP69K.
• Unitized, molded coil design.
• Reduce manifold space claim.
RATINGS
Operating Pressure: 250 bar (3625 psi); Holding Pressure at 1: 250 bar (5000 psi)
Flow: 15 gpm (57 lpm); see performance charts
Internal Leakage: Ports 1 and 3: 5 drops/minute max. at 250 bar (3625 psi)
Port 2: 10 drops/minute max. at 250 bar (3625 psi)
Operating Temperature: -40° to 100°C (-40° to 212° F) with standard Buna N seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals;
-54°C to 104°C (-65°F to 225°F) with Polyurethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard D-Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-3, Variation “B”; See page 9.110.1
Cavity Tool: CT10-3XX; See page 8.600.1
Seal Kit: SK10-3X-MM; See page 8.650.1
Coil Nut: Part No. 7004400
SVCL10-32 Poppet, 3-Port, Normally Closed
SYMBOL
1.315.1
PERFORMANCE (Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
ISO:
Expanded:
3 to 1
32 cSt/150 sus oil at 40°C
17.2/250
13.7/200
10.3/150
6.9/100
3.4/50
22.7
6
45.4
12
56.8
15
FLOW lpm/gpm
PRESSURE DROP bar/psi
11.4
3
34.1
9
3 to 2 1.2A
32 cSt/150 sus oil at 40°C
1.03/15
0.83/12
0.62/9
0.41/6
0.21/3
0.76
0.2
1.52
0.4
1.90
0.5
FLOW lpm/gpm
PRESSURE DROP bar/psi
0.38
0.1
1.14
0.3
U.S. Patent
7,921,880
Blue rectangles are links to other catalog pages.
DIMENSIONS
SVCL10-32
1.315.2
TO ORDER
Cartridge: Weight: 0.18 kg.
(0.40 lbs.); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Buna N
O-rings and polyester elastomer
back-up standard.
Standard D-Coil: Weight: 0.27 kg.
(0.60 lbs.); Unitized thermoplas-
tic encapsulated, Class H high
temperature magnetwire. See
page 3.200.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.);
Fully encapsulated with rugged
external metal shell. Rated up to
IP69K with integral connectors.
Note: See page 3.400.1 for all
E-Coil retrofit applications.
MATERIALS
®
HYDRAFORCE
HYDRAFORCE
.com
®
1.62
41.1
1.84
DIA.
46.7
E-Coil
View
TORQUE
5–7 ft-lbs
(6.8–9.5 Nm)
TORQUE
33–37 ft-lbs
(44.8–50.2 Nm)
1.00
25.4
2.93
74.4
2.32
59.0
0.87
22.1
1.48
37.6
D-Coil
View
U.S. Patent 7,921,880
SVCL10-32__ - __ __ __ - __ - __ __ __ __ __
Porting
Cartridge Only 0
Seals
Buna N (Std.) N
Fluorocarbon V
Polyurethane P
Voltage
0 Less Coil**
12 12 VDC
20 20 VDC
†
24 24 VDC
**Includes D-Coil Nut
For Coils with Zener Diode, add “/Z” to option code.
For example: “ER/Z”. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
Coil Termination E-Coil D-Coil
Deutsch DT04-2P ER (IP69K) DR (IP65)
Metri-Pack
®
150 EY (IP69K) DY (IP65)
Dual Lead Wires EL (IP69K) DL (IP65)
Amp Jr. Timer EJ (IP67) —
DIN 43650 EG (IP65) DG (IP65)
Dual Spades — DS (IP65)
Option
None (Blank)
Manual Override M
Blue rectangles are links to other catalog pages.