SV58-P20A Poppet, 2-Way, Normally Closed
DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw-in hydraulic
cartridge valve with integral neutral sensor, designed to function as a load holding
or blocking valve in applications requiring low internal leakage.
OPERATION
When de-energized, the SV58-P20A acts as a check valve, allowing flow from 1 to 2,
while blocking flow in the reverse direction. The neutral sensor will transmit an “Off”
signal. When energized, the poppet lifts to open the 2 to 1 flow path. In this mode,
flow from 1 to 2 is severely restricted. The neutral sensor will transmit an “On” signal.
FEATURES
• Continuous-duty rated solenoids with optional coil voltages and terminations.
• Hardened seat for long life and low leakage.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Integral position sensor, EMI/RFI CE-rated.
• Unitized, molded coil design — optional waterproof E-Coils rated up to IP69K.
• Industry common cavity.
RATINGS
Operating Pressure: 345 bar (5000 psi)
Proof Pressure: 483 bar (7000 psi)
Burst Pressure: 634 bar (9200 psi)
Flow: up to 18.9 lpm (5 gpm), see Performance Chart
Internal Leakage: In Neutral: 0.15 cc/min. (5 drops/min.) max. at 345 bar (5000 psi)
Typical Flow (Leakage) in Transition: 0.3 lpm (0.8 gpm) at 345 bar (5000 psi);
see Flow vs. Valve Shift graph.
Temperature: -54°C to 107°C (-65°F to 225°F) with Polyurethane seals;
Sensor Option: -40°C to 110°C (-40°F to 230°F)
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Pull-In Response Time: 57 ms (first indication of change when 100% voltage
is applied to the coil)
Drop-Out Response Time: 152 ms (first indication of change when voltage
goes to zero)
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-2; See page 9.108.1;
Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2P-T; See page 8.650.1
Coil Nut: Part No. 7004400
Position Sensor Ratings: See Sensor Option page 3.010.1
1.025.1
SYMBOL
PERFORMANCE
(Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
19.3/280
16.5/240
13.8/200
11.0/160
8.3/120
7.6
2
15.9
4
22.7
6
FLOW lpm/gpm
PRESSURE bar/psi
SV58-P20A with Sensor
1 to 2 de-energized ——
2 to 1 energized - - - -
32 cSt/150 sus oil at 40°C
30.3
8
5.5/80
2.8/40
VALVE SHIFT %
FLOW
Vcc
SENSOR OUTPUT
Typical Sensor Output vs. Valve Shift
0
0.3 lpm
0.08 gpm
56.8 lpm
15 gpm
15 20 50 100
VOUT
Hatched Area: Overlapping Stroke, Leakage Flow