SV12-20 Poppet, 2-Way, Normally Closed
DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw-in hydraulic
cartridge valve, designed to function as a load holding or blocking valve in
applications requiring low internal leakage.
OPERATION
When de-energized, the SV12-20 acts as a check valve, allowing flow to pass from
1 to 2, while blocking flow in the reverse direction.
When energized, the poppet lifts to open the 2 to 1 flow path. In this mode,
flow from 1 to 2 is severely restricted. If this path is required, see model SV12-22,
page 1.045.1.
Operation of Manual Override Option: To override, push button in, twist counter-
clockwise 180° and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise 180° and release.
Override will be detented in this position.
FEATURES
• Continuous-duty rated solenoid. • Manual override option.
• Hardened seat for long life and low leakage. • Unitized, molded coil design.
• Optional coil voltages and terminations. • Cost effective cavity.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Optional waterproof E-Coils rated up to IP69K.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Proof Pressure: 345 bar (5000 psi)
Flow: 30 gpm (114 lpm); see performance chart
Internal Leakage: 0.15 cc/minute (3 drops/minute) max. at 240 bar (3500 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at
80% of nominal flow rating: Energized: 40 msec.; De-energized: 80 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified);
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 240 bar (3500 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC12-2; See page 9.112.1
Cavity Tool: CT12-2XX; See page 8.600.1
Seal Kit: SK12-2X-T; See page 8.650.1
Coil Nut: Part No: 7004400;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
ISO:
with Sensor:
1.018.1
10.3/150
8.3/120
6.2/90
4.1/60
2.1/30
37.9
10
75.8
20
113.6
30
FLOW lpm/gpm
PRESSURE DROP bar/psi
2 to 1 energized ——
1 to 2 de-energized - - - -
32 cSt/150 sus oil at 40°C
SYMBOLS
PERFORMANCE
(Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
17.2/250
20.7/300
24.1/350
27.6/400
13.8/200
10.3/150
6.9/100
3.4/50
18.9
5
37.9
10
56.8
15
75.7
20
FLOW lpm/gpm
PRESSURE DROP bar/psi
SV12-20 with Sensor
Port 2 to 1 Energized - - - -
Port 1 to 2 De-energized ——
32 cSt/150 sus oil at 40°C
94.6
25
114
30
VALVE SHIFT %
FLOW
Vcc
SENSOR OUTPUT
Typical Sensor Output & Flow vs. Valve Shift
0
0.1 lpm
0.4 gpm
30 lpm
113.6 gpm
10 15 50 100
Hatched Area: Overlapping Stroke, Leakage Flow
VOUT
Blue rectangles are links to other catalog pages.