294
E 7.562.3/03.12
FLN BN/HC 250 D F 10 D 1 . X /-L24
Filter type
FLN
Filter material of element
BN/HC Betamicron
®
(BN4HC)
W/HC Stainless steel wire mesh
Size of lter or element
FLN: 160, 250, 400
Operating pressure
D = 25 bar
Type and size of port
to DIN 24550 ( ), possible ports ( X )
Type Port Filter size
160 250 400
E G 1¼
X X
F G 1½ X
X
K DN 38* X X
*Flange SAE 1½", 3000 PSI
Filtration rating in µm
BN/HC: 3, 6, 10, 25
W/HC: 25, 50, 100, 200
Type of clogging indicator
Y plastic blanking plug in indicator port
A steel blanking plug in indicator port
B visual
C electrical for other clogging indicators,
D visual and electrical see brochure no. 7.050../..
LZ visual-mechanical / electrical
Type code
1
Modication number
X the latest version is always supplied
Supplementary details
A. pressure setting (e.g. A2 = 2 bar)
B. bypass cracking pressure (e. g.: B3.5 = 3.5 bar; B7 = 7 bar); no details = without bypass valve
L... light with appropriate voltage (24, 48, 110, 220 Volt) only for clogging
LED 2 light-emitting diodes 24 Volt indicators Type "D"
AV LZ indicator with plug to AUDI and VW specications
BO LZ indicator with plug and pin connections to BMW and Opel specication (M12x1)
CN LZ indicator with plug to DIN 43651 with 3 LEDs (CNOMO specication)
DB LZ indicator with plug to DIN 43651 with 3 LEDs (Daimler-Benz specication)
D4C LZ indicator with plug and connector to Daimler-Chrysler specication and cold start suppression 30 °C
BO-LED as for BO, but with diode strip
V FPM seals
W suitable for HFA and HFC emulsions
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
0250 DN 010 BN4HC /-V
Size
0160, 0250, 0400
Type
DN
Filtration rating in µm
BN4HC : 003, 006, 010, 025
W/HC : 025, 050, 100, 200
Filter material
BN4HC, W/HC
Supplementary details
V, W (for descriptions, see point 2.1)
2.2 REPLACEMENT ELEMENT
2.3 REPLACEMENT CLOGGING INDICATOR VM 5 D . X /-L24
Type of indicator
VM Differential pressure indicator up to 210 bar operating pressure
VD Differential pressure indicator up to 420 bar operating pressure (only for types LE and LZ)
Pressure setting
5 standard 5 bar, others on request
Type of clogging indicator
D (see Point 2.1)
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V, W (for descriptions, see point 2.1)