313
E 7.557.3/03.12
Inline Filter DFN/DFNF/LFN/LFNF
to DIN 24550
up to 400 l/min, up to 400 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl.
DFNF and LFNF lters are suitable for
ow in both directions.
Standard equipment:
without bypass valve
connection for a clogging indicator
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities
in g
Betamicron
®
(BN4HC)
LFN, LFNF 3 µm 6 µm 10 µm 25 µm
DFN, DFNF
40 5.2 5.6 6.3 7.0
63 9.2 9.9 11.1 12.8
100 15.4 16.5 18.6 20.6
160 27.5 29.3 33.1 36.7
250 46.0 49.0 55.2 61.3
400 76.2 81.3 91.4 101.5
Betamicron
®
(BH4HC)
LFN, LFNF 3 µm 6 µm 10 µm 25 µm
DFN, DFNF
40 4.1 4.4 5.2 6.2
63 7.3 7.9 9.2 11.2
100 12.2 13.2 15.5 18.9
160 21.8 23.9 27.8 33.8
250 38.1 41.7 48.6 59.0
400 63.6 69.5 81.0 98.3
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BH4HC): 160 bar
Wire mesh (W/HC): 20 bar
1.4 SEALS
NBR (= Perbunan)
1.5 INSTALLATION
As inline lter
1.6 SPECIAL MODELS AND
ACCESSORIES
with bypass valve
FPM seals
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
1.10 IMPORTANT INFORMATION
Filter housings must be earthed.
When using electrical clogging
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
1.3 FILTER SPECIFICATIONS
Nominal pressure 100 bar : all LFN and LFNF
210 bar : DFN 160, 400
400 bar : DFN 40, 63, 100, 250
DFNF 40, 63, 100
Fatigue strength At nominal pressure 10
6
cycles
from 0 to nominal pressure
Temperature range -30 °C to +100 °C
(-30 °C to -10 °C = 200 bar - only DFN/F)
Material of lter head (and cover plate) EN-GJS-400-15 : DFN/F
Aluminium : LFN/F
Material of lter bowl (tube) Steel : DFN/F
Aluminium : LFN/F 40, 63
Steel : LFN/F 100
Type of indicator VM (Diff. pressure ind. up to 210 bar
oper. pressure - not for type LZ)
VD (Diff. pressure ind. up to 420 bar
oper. pressure)
Pressure setting of the clogging indicator 5 bar (others on request)
Bypass cracking pressure (optional) 7 bar (others on request)
Symbol for hydraulic systems
DFN / LFN
LFN/F
40
E 7.557.3/03.12
LFN/F
63
LFN/F
100
DFN/F
40
DFN/F
63
DFN/F
100
DFN
160
DFN
250
DFN
400
DFNF/
LFNF
314
E 7.557.3/03.12
DFN BN/HC 250 S F 10 D 1 . X /-L24
Filter type
DFN, LFN, LFNF, DFNF
Filter material of element
BN/HC Betamicron
®
(BN4HC) BH/HC Betamicron
®
(BH4HC)
W/HC Wire mesh
Size of lter or element
DFN: 40, 63, 100, 160*, 250, 400 (*on request)
DFNF: 40, 63, 100
LFN/F: 40, 63, 100
Operating pressure
I = 100 bar (LFN and LFNF)
L = 210 bar (DFN 160, 400)
S = 400 bar (DFN 40, 63, 100, 250; DFNF 40, 63, 100)
Type and size of connection
Type Connection Filter size
40 63 100 160 250 400
B G ½
x x
C G ¾ x
x
D G 1 x x
E G 1¼
x x
F G 1½ x
x
K DN 40* x x
*Flange SAE, 6000 PSI
Filtration rating in µm
BN/HC, BH/HC: 3, 6, 10, 25 W/HC: 25, 50, 100, 200
Type of clogging indicator
Y plastic blanking plug in indicator port
A steel blanking plug in indicator port
B visual
C electrical for other clogging indicators,
D visual and electrical see brochure no. 7.050../..
LZ visual-mechanical / electrical
Type code
1 DFN / DFNF
2 LFN / LFNF
Modication number
X the latest version is always supplied
Supplementary details
B. bypass cracking pressure (e.g. B7 = 7 bar); without details = without bypass valve
L... light with appropriate voltage (24V, 48V, 110V, 220V)
only for clogging
LED 2 light emitting diodes up to 24 Volt indicators type D
AV LZ indicator with plug to AUDI and VW specication
BO LZ indicator with plug and pin connection to BMW and Opel specication (M12x1)
CN LZ indicator with plug to DIN 43651 with 3 LEDs (CNOMO specication)
DB LZ indicator with plug to DIN 43651 with 3 LEDs (Daimler-Benz specication)
D4C LZ with plug and pin connection to Daimler-Chrysler specication and cold start suppression 30°C
BO-LED as for BO, but with diode strip
SO368 inlet and outlet G ½ (without RI connection; only for DFN/F 40, 63, 100)
V FPM seals
W suitable for HFA and HFC emulsions
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
0250 DN 010 BN4HC /-V
Size
0040, 0063, 0100, 0160, 0250, 0400
Type
DN
Filtration rating in µm
BN4HC, BH4HC: 003, 006, 010, 025 W/HC: 025, 050, 100, 200
Filter material
BN4HC, BH4HC, W/HC
Supplementary details
V (for descriptions, see point 2.1)
2.2 REPLACEMENT ELEMENT
2.3 REPLACEMENT CLOGGING INDICATOR VM 5 D . X /-L24
Type of indicator
VM differential pressure indicator up to 210 bar operating pressure (not for type LZ)
VD differential pressure indicator 420 bar operating pressure
Pressure setting
5 standard 5 bar, others on request
Type of clogging indicator (see Point 2.1)
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V, W (for descriptions, see point 2.1)
315
E 7.557.3/03.12
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing ∆p and the element ∆p and is
calculated as follows:
∆p
total
=∆p
housing
+∆p
element
∆p
housing
= (see Point 3.1)
∆p
element
= Q •
SK*
•
viscosity
1000 30
(*see Point 3.2)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
3.1 ∆p-Q HOUSING CURVES BASED
ON ISO 3968
The housing curves apply to mineral oil
with a density of 0.86 kg/dm³ and
a kinematic viscosity of 30 mm²/s.
In this case, the differential pressure
changes proportionally to the density.
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm²/s. The pressure drop changes proportionally to the change in
viscosity.
DFN 40, 63, 100
LFN 40, 63, 100
∆p [bar]
Q [l/min]
DFNF / LFNF 40, 63, 100
∆p [bar]
Q [l/min]
DFN 160, 250, 400
∆p [bar]
Q [l/min]
∆p [bar]
Q [l/min]
BN4HC: DFN / DFNF / LFN / LFNF 40
∆p [bar]
Q [l/min]
BN4HC: DFN / DFNF / LFN / LFNF 63
∆p [bar]
Q [l/min]
BN4HC: DFN 160
∆p [bar]
Q [l/min]
BN4HC: DFN 250
LFN/F BH4HC W/HC
DFN/F 3 µm 5 µm 10 µm 20 µm –
40 40.4 24.8 16.4 10.9 0.966
63 29.0 18.2 11.7 7.6 0.54
100 19.0 11.7 7.7 5.3 0.325
160 8.0 5.1 3.8 2.5 0.168
250 5.4 3.4 2.8 1.9 0.101
400 3.4 2.1 1.7 1.1 0.068
∆p [bar]
Q [l/min]
BN4HC: DFN / DFNF / LFN / LFNF 100
∆p [bar]
Q [l/min]
BN4HC: DFN 400
316
E 7.557.3/03.12
NOTE
The information in this brochure relates to the operating conditions and
applications described.
For applications and operating conditions not described, please contact the relevant
technical department.
Subject to technical modications.
HYDAC FILTERTECHNIK GMBH
Industriegebiet
D-66280 Sulzbach/Saar, Germany
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
Type b1 b2 b3 d1 d2 d3 d4 d5 d6 d7 h1 h2 h3 h4 h5 SW1 SW2 t1 t2 t3
LFN 40 90 56 32 84 68 G ½ 34 M6 52 48 90 57 39 6 75 27 27 1 14 9
LFN 63 90 56 32 84 68 G ¾ 44 M6 52 48 150 57 39 6 75 27 27 1 17 9
LFN 100 160
*1)
56 32 84 65 G 1 - M6 52 48 245.5 57 39 6 75 27 27 - 24.5 9
LFNF 40 90 56 32 84 68.2 G ½ 34 M6 52 48 90 57 39 6 75 27 27 1 14 9
LFNF 63 90 56 32 84 68.2 G ¾ 44 M6 52 48 150 57 39 6 75 27 27 1 17 9
LFNF 100 160
*1)
56 32 84 65 G 1 - M6 52 48 245.5 57 39 6 75 27 27 - 24.5 9
4. DIMENSIONS
LFN, LFNF
Type Weight Volume of
incl. element pressure
[kg] chamber [l]
LFN 40 1.45 0.26
LFN 63 1.8 0.40
LFN 100 4.3 0.50
LFNF 40 1.45 0.26
LFNF 63 1.8 0.40
LFNF 100 4.3 0.50
DFN 40 5.0 0.22
DFN 63 6.0 0.33
DFN 100 6.25 0.50
DFN 160 20.0 1.10
DFN 250 22.0 1.70
DFN 400 26.5 2.70
DFNF 40 5.0 0.22
DFNF 63 6.0 0.33
DFNF 100 6.25 0.50
port for
clogging indicator
SW 3
oil drain (SO 184)
inlet
outlet
DFN / DFNF 40 - 100
port for
clogging indicator
vent
(SW5)
test point
G 1/8
oil
drain
SW10
DFN...S C: G3/4, 22 deep
DFN...S B: G1/2, 14 deep
Version DFN
40/63/100 S D (G1)
DFN..S B../-SO368:92
4 x M6 / 9 deep
inlet
outlet
Ø 68.20
(size 100:
Ø65)
size 63: 145.50
size 100: 237
size 40: 86
size 63: 214
size 100: 305.50
size 40: 145.50
Version DFN...S C (G3/4): 150
Version DFN...S B (G1/2): 114
DFN 160 - 400
port for
clogging indicator
vent
(SW5)
test point
G 1/8
oil
drain
SW10
DFN...F: G1 1/2, 22 deep
DFN...E: G1 1/4, 26 deep
4 x M12 / 17 deep
inlet
outlet
size 160: 139
size 250: 229
size 400: 379
size 160: 239.50
size 250: 329.50
size 400: 479.50
4 x M16 / 22 deep
*1) for G1 ports
applies to all sizes
45
6
167
DFN...F: 163
DFN...E: 235
SW 27
158
79.40
Ø38
36.7
SW 36
DFN...F: Ø68
DFN...E: Ø55
Ø 115.50
60
105
40
112
115
Ø 157