115
E 7.408.1/03.12
Tank Breather Filter BF
up to 11000 l/min
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
Breather lter sizes 4, 10, 3 and 30
consist of a housing which is screwed
onto the oil tank, and a built-in lter
element.
Sizes 5, 52, 7 and 72 have housings
which are screwed onto the oil tank
and have one or two exchangeable
lter element(s).
BF 5 and 52 are tted with a built-in oil
mist trap as standard.
Sizes 8 and 9 consist of a ange for
mounting to the tank, an exchangeable
element and a cap. The BF 9 also has
an oil mist trap which allows the oil to
be drained via an oil drain plug.
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities
in g
Paper
BF 3 µm
4 2.9
10 2.9
3 6.2
30 6.2
7 26.1
72 52.2
5 85.1
52 170.2
The lter elements are made from phenolic resin
impregnated paper and cannot therefore be
cleaned.
1.4 SEALS
NBR (= Perbunan) on lter
Polyurethane on element
Cardboard on mounting ange
1.5 SPECIAL MODELS AND
ACCESSORIES
with check/bypass valve to support the
suction characteristics of the pump
Not 100% air-tight or leakage-free!
(only BF 10 (except for G¼), 3, 30, 5
and 52)
with anti-splash device
(only BF 10, 3, 30, 7, 72)
with connection for a clogging indicator
(only BF 7, 72, 8, 9)
with manual pressure release
(= BFPR; only BF 10)
1.6 SPARE PARTS
See Original Spare Parts List
1.7 CERTIFICATES, APPROVALS,
STANDARDS
BF 7, 72 to Renault standard;
others on request
1.8 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
The standard models are suitable for
use with mineral and lubrication oils.
For re-resistant and biodegradable
oils, see tables:
Fire-resistant uids
BF HFA HFC HFD-R
4, 3, 5, 52 – – –
10, 30, 7, 72 –
8, 9 
HFA oil in water emulsion
(H
2
O content ≥ 80%)
HFC water polyglycol solution
(H
2
O content 35-55%)
HFD-R synthetic, water-free
phosphate ester
1.3 FILTER SPECIFICATIONS
Temperature range -30 °C to +100 °C
Material of housing Steel, zinc-plated/plastic coated
(BF 4, 3),
Steel (BF 5, 52)
Steel, galvanized (BF 8)
Aluminium (BF 9)
Glass bre reinforced plastic
(BF 10, 30, 7, 72)
Type of clogging indicator VMF (pressure gauge)
Pressure setting of clogging indicator 0.6 bar K pressure gauge
0.035 bar UBM indicator
(others on request)
BF4
E 7.408.1/03.12
Biodegradable uids
BF HTG HE HPG
PAG PRG
4, 10, 3, 30, + + 
7, 72, 5, 52 + + 
8, 9 + + 
+ suitable for all
contact our Technical Sales Department
– not suitable
HTG vegetable oil based hydraulic
uids
HE ester-based synthetic hydraulic
uids
HPG polyglycol-based synthetic
hydraulic uids
PAG sub-group HPG:
polyalkylene glycol
PEG sub-group HPG:
polyethylene glycol
1.9 CHANGING INTERVALS
The lter elements or lters must be
replaced as frequently as the uid
lters, but at least every 12 months.
Symbol
BF10 BF3 BF30 BF7 BF72 BF5 BF52 BF8 BF9
116
E 7.408.1/03.12
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
2.1.1 BF 4 and 3
BF P 72 G 3 W 1 . X /-AS
Filter type
BF
Filter material
P Paper
Size
BF 7, 72
Type and size of connection
Des. Type Connection Filter size
7 72
G Thread G 1 • •
ISO 228
N NPT-
3
/
4
• •
Thread
U UNF- G 1
5
/
16
-12UN • •
Thread
Filtration rating in µm
P 3 (absolute)
Type of clogging indicator
W without port, no clogging indicator
K pressure gauge (measuring range
-1 to +0.6 bar) (not for BF 72)
UBM visual/analogue vacuum gauge
with manual reset
(pressure setting: -0.035 bar)
Type code (TKZ)
1
Modication number
X the latest version is always supplied
Supplementary details
AS anti-splash device
(not for model with K pressure gauge)
2.1.3 BF 7 and 72
BF P 3 G 3 W 4 . X /-RV
Filter type
BF
Filter material
P Paper
Size of lter
BF 4, 3
Type and size of connection
Des. Type Connection Filter size
BF4 BF3
G Thread G ¼ •
ISO 228 G ½ •
G ¾ •
G 3/8 •
Filtration rating in µm
P 3 (absolute)
Type of clogging indicator
W without port, no clogging indicator
Type code (TKZ)
Size Code Connection ∆p [bar]
BF 3 1.X G ¾ -
BF 3 2.X G 3/8 -
BF 3 3.X G ½ -
BF 3../-RV 4.X G ¾ 0.4
BF 3../-RV 5.X G ¾ 0.7
BF 3../-RV 6.X G ¾ 0.2
BF 3../-RV 7.X G ¾ 1.0
BF 4 1.X G ¼ -
Modication number
X the latest version is always supplied
Supplementary details
RV check/bypass valve (not for BF 4)
BF P 52 G 3 W 1 . X /-RV0.4
Filter type
BF
Filter material
P Paper
BN Betamicron
®
Size
BF 5, 52
Type and size of connection
Des. Type Conn. Filter size
5 52
G Thread G 2½ • •
ISO 228
Filtration rating in µm
BN 3, 10 (absolute)
P 3 (absolute)
Type of clogging indicator
W without port, no clogging indicator
Type code (TKZ)
1
Modication number
X the latest version is always supplied
Supplementary details
RV0.4 check/bypass valve with 0.4 bar pressure setting
SO479 lter suitable for HFC uids
2.1.4 BF 5 and 52
BF P 30 G 3 W 1 . X /-RV
Filter type
BF
Filter material
P Paper
Size
BF 10, 30
Type and size of connection
Des. Type Connection Filter size
BF10 BF30
G Thread G ¼ •
G
3
/
8
•
ISO 228 G ¾ •
M metr. connection M 42x2 •
M 30x1.5 •
M 22x1.5 •
N NPT thread ½ •
¾ •
U UNF thread 1 1/16-12UN-2A • •
Filtration rating in µm
P 3 (absolute)
Type of clogging indicator
W without port, no clogging indicator
Type code (TKZ)
Size Code Connection
BF 30 G… 1.X G ¾
BF 30 M… 1.X M 42x2
BF 30 M... 2.X M 30x1.5
BF 30 N... 1.X NPT ¾
BF 30 U... 1.X 1 1/16-12UN-2A
BF 10 G... 1.X G ¼
BF 10 G... 2.X
G
3
/
8
BF 10 M... 1.X M 22x1.5
BF 10 N 1.X NPT ½
Modication number
X the latest version is always supplied
Supplementary details
AS anti-splash without check/bypass valve
RV0.2
RV0.4
valve with relevant pressure setting
RV0.7
(not for BF 10 with G 1/4)
2.1.2 BF 10 and 30
117
E 7.408.1/03.12
BF BN 8 F 1 W 1 . X
Filter type
BF
Filter material
BN Betamicron
®
BN/AM Betamicron
®
/Aquamicron
®
Size
BF 8, 9
Type and size of connection
Des. Type Filter size
8 9
F Flange • •
Filtration rating in µm
BN 1, 2 for BF 8
BN 2 for BF 9
BN/AM 1 for BF 8
Type of clogging indicator
A blanking plug in indicator port
K pressure gauge (measuring range -1 to +0.6 bar)
Type code (TKZ)
1
Modication number
X the latest version is always supplied
2.1.5 BF 8 and 9
0005 L 003 P
Size
0005 for BF 5, 52 (on BF 52: 2 x 0005 L...)
0007 for BF 7
0072 for BF 72
0008 for BF 8
0009 for BF 9
Type
L
Filtration rating in µm
P: 003 (BF 5, 52, 7, 72)
BN: 001, 002 (BF 8)
BN: 002 (BF 9)
BN: 003, 010 (BF 5, 52)
BN4AM: 001 (BF 8)
Filter material
P Paper (BF 5, 52, 7, 72)
BN Betamicron
®
(BF 5, 52, 8, 9)
BN4AM Betamicron
®
/Aquamicron
®
(BF 8)
Replacement elements cannot be ordered for BF 4, 10, 3, 30.
These lters are only available complete!
2.2 REPLACEMENT ELEMENT
VMF 0.6 K . X
Type
VMF Return line indicator
Pressure setting
0.6 -1 to +0.6 bar
0.035 -0.035 bar
Type
A blanking plug in indicator port
K pressure gauge (pressure setting -1 to +0.6 bar)
UBM visual-analogue vacuum gauge with manual
reset (pressure setting: -0.035 bar)
Modication number
X the latest version is always supplied
2.3 REPLACEMENT CLOGGING INDICATOR
118
E 7.408.1/03.12
BF P 7 F 3 UBM 0 . X
Size
7 Tank volume from 20 to 400 litre
72 Tank volume over 400 litre
Type and size of connection
Des. Type Filter size
7 72
G with threaded • •
adapter
F with ange • •
adapter
S with weld • •
adapter
Type of clogging indicator
UBM visual analogue vacuum pressure gauge with manual reset, measuring range 0 to +0.035 bar
Type code (TKZ)
0 without adapter (basic model)
2 incl. adapter with male thread G ¾
3 incl. adapter with female thread 1½-16 UNC
4 incl. adapter with female thread G ¾
5 incl. ange adapter (1½-16 UNC)
6 incl. ange adapter (G ¾)
7 incl. weld adapter (1½-16 UNC)
8 incl. weld adapter (G ¾)
9 incl. adapter with male thread G 1¼
Modication number
X the latest version is always supplied
EFS Filling protection
2.4 MODEL CODE FOR BF 7 AND 72 TO RENAULT SPECIFICATION
Basic model With threaded adapter With ange adapter With weld adapter
Dimensions BF 7/72 to RENAULT specication
For further information on the BF7/72 to Renault specication please contact HYDAC!
BF 7 BF 72
Interface to
DIN 24557/Pt 2
approx.
approx.
approx.
approx.
119
E 7.408.1/03.12
2.5 BREATHER FILTER WITH MANUAL PRESSURE RELEASE BFPR
MODEL CODE
Type Filter material Size Type of
connection
Filtration
rating
[µm]
Type of
clogging
indicator
Type
code
Modication
number
Supplementary
details
BFPR P =
phenolic resin
impregnated
paper
10 U =
1 1/16-12UN-2A
others on
request
3 W =
without port (no
clogging indicator)
1 .x =
The latest
version is
always supplied
RV0.35 =
pre-charge pressure
0.35 bar
RV0.7 =
pre-charge pressure
0.7 bar
RV1.15 =
pre-charge pressure
1.15 bar
Required
information!
TECHNICAL DESCRIPTION
Breather lters with manual pressure
release "BFPR" consist of a housing
which is screwed onto the oil tank
and which has an integrated air lter
element.
An integrated valve allows the oil
tank to be pressurized to different
pressures, for example to support the
pump during start-up, thereby avoiding
cavitation of the pump.
The manual pressure release
function enables complete pressure
release which is initiated when the
pressure release button is pressed.
This pressure release is required
for example before carrying out
maintenance on the tank and
connecting pipes or hoses, to prevent
potential accidents or injury by
opening a pressurized system.
This lter must not be used as safety
valve!
Max. ow rate: 200 l/min
Weight: 0.22 kg
Curves and further information on
request!
DIMENSIONS
manual pressure release
O-ring
23.47 x 2.95-NBR-70Sh
120
E 7.408.1/03.12
3. FILTER CALCULATION /
SIZING
3.1 SINGLE PASS FILTRATION
PERFORMANCE DATA FOR AIR
FILTER ELEMENTS
The following separation values were
established under real-life simulated
conditions.
This means that the selected velocity
of the ow against the lter mesh-pack
was 20 cm/s and the contamination
added was 40 mg/m³ of ISO MTD test
dust.
Filtration Retention For particle Filter
rating value d... size material
3 µm d 80 0.74 µm
Paper
d 100 2.64 µm
10 µm d 80 0.25 µm
BN
d 100 0.84 µm
The d 80 value refers to the particle
size which is ltered out at a rate
of 80% during the retention test.
The particle size determined by this
method is called the nominal ltration
rating of the air lter. The d 100
value therefore refers to the particle
size which is ltered out at a rate of
100% during the single pass test.
The particle size determined by this
method is called the absolute ltration
rating of the air lter.
Table of average dust concentrations
in real life:
Urban regions with 3-7 mg/m³ air
a low level of industry
General mechanical 9-23 mg/m³ air
engineering
Construction industry 8-35 mg/m³ air
(wheeled vehicles)
Construction industry 35-100 mg/m³ air
(tracked vehicles)
Heavy industry 50-70 mg/m³ air
3.3 SIZING GUIDELINES
The rate at which contamination enters
a hydraulic system can be considerably
reduced by using efcient tank breather
ltration.
CAUTION:
Incorrectly sized tank breather lters
can place additional strain on the
system and reduce the service life of
hydraulic lter elements.
For optimum sizing the following
should therefore be observed:
Filtration rating of breather lter ≤
ltration rating of hydraulic lter
Only use breather lters with an
absolute retention rate (d100 ≤ x µm;
x = given ltration rating)
Max. permitted initial pressure loss:
0.05 bar, optionally 0.01 bar (with a
clean lter element and calculated air
ow rate)
Determining the calculated air ow:
Q
A
= f5 x Q
p
Q
A
=calculated air ow in l
N
/min
f5=factor for operating conditions
Q
p
=max. ow rate of the
hydraulic pump in l/min
Ambient conditions Factor f5
Low dust concentration;
lter tted with clogging indicator; 1-2
continuous monitoring of the lter
Average dust concentration;
lter without clogging indicator; 3-6
intermittent monitoring of the lter
High dust concentration;
lter without clogging indicator; 7-10
infrequent or no monitoring of the
lter
3.2 DIFFERENTIAL PRESSURE
ACROSS BREATHER FILTER
The differential pressure (with clean
element) for the various lter sizes is
shown in the graphs under Point 3.4.
121
E 7.408.1/03.12
∆p [bar]
Q [l/min]
BF 4
∆p [bar]
Q [l/min]
BF 10
3.4 AIR FLOW RATE
∆p [bar]
Q [l/min]
BF 30
∆p [bar]
BF 3
Q [l/min]
∆p [bar]
Q [l/min]
BF 7
∆p [bar]
Q [l/min]
BF 72
∆p [bar]
Q [l/min]
BF 5
∆p [bar]
Q [l/min]
BF 52
∆p [bar]
Q [l/min]
BF 9
∆p [bar]
BF 8
Q [l/min]
Pressure drop curves for BF lters with
check/bypass valve (version /-RV...)
on request.
122
E 7.408.1/03.12
BF 4 BF 3
Type BF 7 "G" BF 72 "G"
d1 116 116
d2 G 1 G 1
d3 120 120
h1 110 162
h3 18 18
h4 60 90
b1 44 44
SW 41 41
Weight 0.40 kg 0.65 kg
Type BF 7 "N" BF 72 "N"
d1 116 116
d2 NPT ¾ NPT ¾
d3 120 120
h1 110 162
h3 18 18
h4 60 90
b1 44 44
SW 32 32
Weight 0.40 kg 0.65 kg
Type BF 7 "U" BF 72 "U"
d1 116 116
d2 1 5/16-12 UN 1 5/16-12 UN
d3 120 120
h1 110 162
h3 18 18
h4 60 90
b1 44 44
SW 41 41
Weight 0.40 kg 0.65 kg
4. DIMENSIONS
BF 10 BF 30
BF 7
BF 72
Type BF 4...
d1 44
d2 G ¼
d5 8
h1 62
h3 13.5
SW 17
Weight 0.08 kg
Type BF 10 "G"... BF 10 "M"...
d1 49 49
d2 G ¼ M22x1.5
d5 7 16
h1 64 71
h3 13.5 18
Weight 0.047 kg 0.052 kg
Type BF 10 "U"... BF 10 "N"...
d1 49 49
d2 1 1/16-12 UN NPT ½
d5 16 14
h1 71 71
h3 18 18
Weight 0.059 kg 0.049 kg
Type BF 3...1.X BF 3...2.X BF 3...3.X
d1 76 76 76
d2 G ¾ BSP 3/8" G ½
d5 19 12 15
h1 79 72 76
h3 16 12 14
SW 36 22 27
Weight 0.33 kg
Type BF 30
"G"...1.X
BF 30
"M"...1.X
BF 30
"M"...2.X
d1 83 83 83
d2 G ¾ M42x2 M30x1.5
d5 20.5 34.5 20.5
h1 76 76 76
h3 16 16 16
SW 32 46 32
Weight 0.12 kg 0.13 kg 0.12 kg
Type BF 30
"N"...1.X
BF 30
"U"...1.X
d1 83 83
d2 NPT ¾ 1 1/16-12 UN
d5 20.5 20.5
h1 76 76
h3 16 16
SW 32 32
Weight 0.12 kg
123
E 7.408.1/03.12
BF 5 BF 8 BF 9
BF 52
Interface Interface
Type BF 5... BF 52...
d1 177 177
d2 G 2½ G 2½
h1 107 173
h4 90 90
Weight 2.00 kg 2.60 kg
Type BF 8...
d1 200
d2 200
d4 93
d5 160
d6 18
h1 510
h2 365
h4 400
h6 20
Weight 12.4 kg
Type BF 9...
d1 250
d2 177
d3 246
d4 116
d5 210
d6 17
h1 455
h2 290
h4 330
h6 8
Weight 6.2 kg
124
E 7.408.1/03.12
NOTE
The information in this brochure relates to the operating conditions and
applications described.
For applications or operating conditions not described, please contact the relevant
technical department.
Subject to technical modications.
HYDAC FILTERTECHNIK GMBH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
NOTES