540
E 5.991.9.0/12.10
Proportional
Flow Control Valve
Spool Type, Direct Acting,
Normally Closed
Metric Cartridge – 250 bar
PWK12120W
70 l/min
250 bar
The PWK12120W is a normally closed,
direct-acting, proportional ow control
valve.
It smoothly controls the ow from
port 1 to port 2.
The energization of the coil reduces or
increases an orice cross-section and
thus controls the ow.
Together with a pressure compensator
the proportional ow control valve can
be used as a proportional 2-way ow
regulator – for example when required
to lift/lower variable loads at the same
velocity.

z Stepless adjustment of the effective oil ow, depending on the coil current.
z Excellent stability throughout ow range
z Low hysteresis
z Excellent dynamic performance
z All exposed surfaces zinc-plated and corrosion-proof
z All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
z Solenoid seals protect the solenoid system
z Wide variety of connections available
z Low pressure drop due to CFD optimized ow-path
z Different ow rate ranges available


Operating pressure: max. 250 bar
Nominal ow: max. 70 l/min
Internal leakage: max. 900 ml/min at 250 bar
Media operating temperature range: min. -30 °C to max. +100 °C
Ambient temperature range: min. -30 °C to max. +60 °C
Fluid: Hydraulic oil to DIN 51524 Part 1 + 2
Viscosity: min. 10 mm²/s to max. 420 mm²/s
Filtration: Class 19/17/14 to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: No orientation restrictions
Materials: Valve body: steel
Piston: hardened and
ground steel
Seals: NBR (standard)
FKM (optional,
temperature range
to -20 °C)
Back-up rings: PTFE
Cavity: Metric 12120
Weight: Valve complete 0.75 kg
Coil only 0.35 kg
Electrical data
Control currents: 800 mA, 19.2 Ohm (24 Volt)
1600 mA, 5.0 Ohm (12 Volt)
Dither frequency: approx. 120 Hz
Coil duty rating: 100 %
Hysteresis with dither: ≤ 5 % of nominal current
Repeatability: ≤ 1 % of nominal current
Reversal error: ≤ 1 % of nominal current
Response sensitivity: ≤ 1 % of nominal current
Coil type: Coil...-50-2345
541
E 5.991.9.0/12.10

PWK12120 W - 01 M - C - N - 25 - 24 PG - 19.2
Basic model
Proportional ow control valve
Cavity 12120 = metric
Function symbol
W = normally closed
Type
01 = standard
Manual override
Omission = no option
M = manual override
Body and ports
C = cartridge only
Seals
V = FKM (standard)
N = NBR (optional)
Flow rate code
20 = 20 l/min at 5 bar Dp and l
max
25 = 25 l/min at 5 bar Dp and l
max
45 = 45 l/min at 5 bar Dp and l
max
Coil voltage
12 = 12 Volt DC (5.0 Ohm)
24 = 24 Volt DC (19.2 Ohm)
Other voltages on request
Coil connectors 50-2345
PG = DIN connector to EN175301-803
PL = Lead wires (2), 0.75mm², 457 mm long
PN = Deutsch connector, 2 pole, axial
PT = AMP Junior Timer, 2 pole, radial
Coil resistance
5.0 = 5.0 Ohm (12V)
19.2 = 19.2 Ohm (24V)
D
Measured at
n 40 mm
2
/s
T
oil
= 42 °C
Standard models
Model code Part No.
PWK12120W-01-C-V-20-24PG-19.2 3578776
PWK12120W-01-C-V-25-24PG-19.2 3578775
PWK12120W-01-C-V-45-24PG-19.2 3356245
PWK12120W-01M-C-V-20-12PG-5.0 3578798
PWK12120W-01M-C-V-25-12PG-5.0 3578796
PWK12120W-01M-C-V-45-12PG-5.0 3354970
Other models on request
Standard line bodies
Code Part No. Material Ports Pressure
R12120-10X-01 396708 Steel, zinc-plated G3/4 420 bar
R12120-10X-02 396707 Steel, zinc-plated M 27 x 2 420 bar
Other line bodies on request
Seal kits
Code Part No.
SEAL KIT 12120-NBR 3454001
SEAL KIT 12120-FKM 3454002

Flow [l/min]
Dp [bar]

Flow [l/min]
Dp [bar]

Flow [l/min]
Dp [bar]
542
E 5.991.9.0/12.10

Millimeter (inch)
Subject to technical modications

Metric 12120
Cartridge form tools
Tools Part No.
Countersink (shank MK3) 172880
Reamer (shank MK2) 1014207
Millimeter (inch)
Subject to technical modications
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str.
D-66280 Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: [email protected]

Measured at
n 40 mm
2
/s
T
oil
= 42 °C
NOTE
The information in this brochure relates to
the operating conditions and applications
described.
For applications or operating conditions
not described, please contact the relevant
technical department.
Subject to technical modications.
tting depth
Torque 4
+2
Nm
hex SW32 metric
Torque 70
+10
Nm
After loosening mounting nut,
coil can be rotated through 360°
and removed
thru
thick
0 10 20 30 40 50 60 70 80 90 100
0
2
4
6
8
10
12
14
16
18
20
22
24
D
Flow [l/min]
% of maximum current
0 10 20 30 40 50 60 70 80 90 100
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
D
Flow [l/min]
% of maximum current
0 10 20 30 40 50 60 70 80 90 100
0
5
10
15
20
25
30
35
40
45
50
D
Flow [l/min]
% of maximum current
543