E 5.978.1.0/12.10
514
Proportional Pressure
Relief Valve
Metric Cartridge – 350 bar
PDBM06020
Poppet Type - Direct Operated
up to 10 l/min
up to 350 bar
The PDBM06020 is a direct-operated,
poppet type proportional pressure relief
valve.
If the pressure at port 1 rises above the
setting dened by the electrical control,
the valve opens and allows ow from
port 1 to port 2. As a function of the
electrical signal, the relief pressure at
port 1 can be set steplessly.
FEATURES
Excellent stability over the whole ow range
Very good dynamics
Exposed surfaces zinc-plated and corrosion-proof
Minimal wear and long service life due to hardened and ground valve
components
Coil seals protect the solenoid system
Wide variety of coils and connectors available
Low pressure drop due to CFD optimised ow-path
Patented design for guided poppet
Excellent dynamic performance
Screen protected measuring orice enhances safety
FUNCTION
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal ow: pressure range 070 bar...max.10 l/min
pressure range 210 bar...max. 6 l/min
pressure range 350 bar...max. 4 l/min
Internal leakage: < 0.1 cm³/min at 80% nominal pressure
Media operating temperature range: min. -20 °C to max. +100 °C
Ambient temperature range: min. -20 °C to max. +60 °C
Fluids: Hydraulic oil to DIN 51524 Part 1 and 2
Viscosity: min 7.4 mm²/s to max. 420 mm²/s
Filtration: Class 19/17/14 to ISO 4406 or cleaner
Installation: optional, vertical preferred
Material: Valve body: steel
Piston: hardened and
ground steel
Seals: NBR (standard)
FKM (optional)
Back-up rings: PTFE
Cavity: 06020 metric
Weights: Valve complete: 0.44 kg
Coil only: 0.22 kg
Electronics
Control currents: 850 mA; 18 Ohm (24V)
1750 mA; 4.1 Ohm (12V)
Dither frequency: 160 - 250 Hz
Hysteresis with dither: 2-4% of max. control current
Repeatability: ≤ 1.5% of max. pressure range
Hysteresis error: ≤ 2% of max. control current
Response sensitivity: ≤ 1% of max. control current
Note:
The PDBM06020 can also be supplied with an emergency pressure adjustment (version -01M).
This allows a mechanical pressure adjustment of the valve if the electrical signal is interrupted.
This adjustment should be used only in the case of electrical failure since the manual setting would
be additive to the electrical setting and the danger of equipment damage could develop.
In order to achieve optimal function, any trapped air should be vented with the bleed screw on the
face of the tube (not tted to version -01M).