E .1/12.10
222
Check Valve
SAE 10-Cartridge – 420 bar
RV10A-01
Ball Type
80 l/min
420 bar
The RV10A allows ow passage from
1 to 2, while normally blocking ow
in the opposite direction. The guided
check is spring-biased closed until
sufcient pressure is applied at 1
to open to 2.

All surfaces zinc-plated and corrosion proof
Hardened closing element
Low leakage design
Compact design


Operating pressure: 420 bar
Nominal ow: 80 l/min
Internal leakage: 0.1 cc/min
max. at 420 bar
Standard cracking pressure: 0.35 bar
1.00 bar
2.00 bar
5.00 bar
Media operating temp. range: -20 °C to +120 °C
Fluids: Mineral-based or synthetics with
lubricating properties
Viscosity: 7.4 to 420 cSt
Filtration: Class 21/19/16 according to ISO 4406
or cleaner
Material: Valve body: carbon steel
Ball: carbon steel
Seals: NBR (standard)
FKM (optional)
Cavity: FC10-2
Weight: 100 g
E .1/12.10
223





C = Cartridge only
SB4 = 1/2 BSP ports, steel body
SS8 = SAE-8 ports, steel body
AB4 = 1/2 BSP ports, aluminium body
AS8 = SAE-8 ports, aluminium body

N = NBR
V = FKM

05 = 0.35 bar
15 = 1.00 bar
30 = 2.00 bar
70 = 5.00 bar


FC10-2
Millimeter (inch)
technical modications
reserved
Millimeter (inch)
technical modications
reserved

 
Rougher FC10-2 in preparation
Finisher FC10-2 in preparation

    
FH102-SB4 3037594 Steel, zinc-plated 1/2 BSP 420 bar
FH102-SS8 3037612 Steel, zinc-plated SAE-8 420 bar
FH102-AB4 3037777 Aluminium, clear anodized 1/2 BSP 245 bar
FH102-AS8 3037778 Aluminium, clear anodized SAE-8 245 bar
Measured at n = 34 mm²/s
T
oil
= 46 °C
ow rate
pressure drop

Justus-von-Liebig-Str.

Tel: 0 68 97 /509-01
Telefax. 0 68 97 /509-598
The information in this brochure
relates to the operating conditions
and applications described.
For applications or operating
conditions not described, please
contact the relevant technical
department.
Subject to technical modications.

l/min
US gpm