Proportional
Pressure Relief Valve
PDB06
up to 350 bar
up to 5 l/min
Connection Housings
PDB06 Cartridge Valves
Control Electronics
E 5.164.4/03.02
2
E 5.164.4/03.02
1. DESCRIPTION
1.1. GENERAL
HYDAC proportional pressure
relief valves, type PDB, are
“control valves for oil hydraulic
systems, where the inlet pressure
is controlled by opening the outlet
port to the tank against a
counter force (solenoid spring
system)“ as specified by
DIN-ISO 1219. The pressure is
controlled electrically, the signal
being supplied by appropriate
control electronics which operate
the solenoid. This solenoid is
of the core tube type and has
the following advantages:
– completely sealed
– low noise level and long service
life due to oil damping
– good heat dissipation via the oil
– solenoid coil can be turned
through 360°, and removed
without having to open the
hydraulic system.
The control electronics for
the valve are available in
three versions and are pre-set
in accordance with the relevant
valve details. The valve design
also allows the use of other
commercially available control
systems, however, in this case
the valve characteristics can be
different to those shown in this
brochure.
The HYDAC proportional
pressure relief valve PDB is
designed as a compact cartridge
valve and has the following
advantages:
– standardised installation space
– space-saving installation in
housings, control blocks etc.
– simple fitting and
exchangeability
– interchangeable with mechanical
pressure relief valves, type DB4
– excellent control and stability
properties
– low hysteresis
– optimum system adjustment by
means of 3 pressure ranges
A wide range of connection
housings is available for a variety
of applications
A plug
B solenoid coil
C solenoid armature
D valve housing
E spring plate
F spring
G closing cone
1.2 FUNCTION
HYDAC PDB proportional
pressure relief valves are direct
operated cone seat valves for oil
hydraulic systems.
The valves consist basically of
a heat-treated valve seat, the
diameter of which varies
according to the pressure range
of the valve, a hardened and
polished closing cone and a
solenoid system for electrical
operation.
The solenoid system of the valve
carries out a stroke against the
spring, depending on the amount
of control current, thereby
producing a certain spring pre-
stress force. The spring applies
this force to the closing cone
and pushes it against the valve
seat. On the opposite side of
the closing cone the system
pressure acts via port 1 of the
pressure valve. If the hydraulic
pressure force is below the pre-
set spring force, the valve is
closed.
If the hydraulic pressure force
exceeds the pre-set spring force,
the closing cone lifts off from the
seat and connects pressure
port 1 with tank port 2. This limits
the system pressure to the value
set by the solenoid system and
the spring.
If the control current to the
solenoid coil is interrupted,
the spring relaxes and the
system pressure drops to the
minimum adjustable pressure
(p=f(Q) at 0 current).
1.3. APPLICATIONS
In oil hydraulic systems for
– remote adjustment of pressure
– automatic or manual adjustment
of system pressure to required
values
– control of pressure performance
– specific modulation of pressure
increase and decrease
– pilot operation of hydraulic valves
and logic elements
– control of adjustment devices on
pumps and in pump control
circuits
1.4. RECOMMENDATIONS
– to safeguard the maximum
permissible system pressure,
it is recommended that a separate
pressure relief valve (e.g. DB4)
is installed
– minimum adjustment pressure to
be taken into account (see point
2.2.9)
– connections to be taken into
account (see point 2.1.7)
– torque figures to be taken into
account (see point 3)
In order to guarantee faultless
operation and a long service life
the following advice is
recommended:
– vent valve during commissioning:
Flush in preferred mounting
position (solenoid pointing
downwards) and repeat operation
several times
– avoid continuous operation of
valve at maximum control
current; in that case the next
highest pressure range should
be used
– the cartridge valve is pre-set by
the manufacturer and must
neither be opened nor adjusted.
3
E 5.164.4/03.02
2. TECHNICAL
SPECIFICATIONS
2.1. GENERAL
2.1.1 Designation and symbol
Proportional
pressure relief valve
When ordering, please state stock no.
For non standard types delivery is longer and the price is higher.
2.1.3 Type of construction
Cone seat valve, direct operated
2.1.4 Type of mounting
Cartridge valve
2.1.5 Mounting position
optional,
solenoid pointing
downwards preferred
(see point 1.4.)
2.1.6 Weight
0.45 kg
2.1.7 Flow direction
According to symbol,
only permissible
in direction of arrow
Port 1:
pressure line (inlet)
Port 2:
tank line (outlet)
2.1.8 Ambient temperature range
Min. - 20 °C
Max. + 40 °C
2.1.9 Materials
Closing cone: hardened steel
Valve seat: high tensile steel
Valve body: free-cutting steel
Seals: FPM and PTFE
2.1.10 Type of connection
Various suitable connection
housings with installation
dimensions 06020 are available.
See separate housing brochure
no. E 5.252../..
2.1.11 Nominal size
NG = 06
2.1.2 Model code
(also order example)
PDB 06020 – 01 X – 070 – G24 – Z4
Proportional pressure relief valve
Installation dimensions
Type
01 = standard
Series
(determined by manufacturer)
Pressure range
070 = up to 70 bar
210 = up to 210 bar
350 = up to 350 bar
Nominal voltage
G24 = 24 V DC
Type of connection, electrical
Z4 = plug to DIN 43650-AF2-PG11
Standard models
Stock no. Model code
716 200 PDB 06020-01X-070-G24-Z4
716 201 PDB 06020-01X-210-G24-Z4
716 202 PDB 06020-01X-350-G24-Z4
4
E 5.164.4/03.02
2.2. HYDRAULIC DETAILS
2.2.1 Nominal pressure
Inlet (port 1) ... up to 350 bar
depending on pressure range
of valve
Outlet (port 2)
no pressure to tank
2.2.2 Operating pressure ranges
... up to 70 bar
... up to 210 bar
... up to 350 bar
for min. adjustment pressure
see p
min
-Q-Graphs (point 2.2.9)
2.2.3 Operating fluid
Hydraulic oil to DIN 51524,
Part 1 and 2
2.2.4 Operating fluid
temperature range
Min. - 20 °C
Max. + 70 °C
2.2.5 Viscosity range
Min. 10 mm²/s
Max. 380 mm²/s
2.2.6 Flow rate
depending on pressure range
pressure range 070:
… up to 5 l/min
pressure range 210:
… up to 5 l/min
pressure range 350:
… up to 3 l/min
2.2.7 Filtration
Max. permissible contamination
rate of the operating fluid to
ISO 4406 Class 20/18/15
(NAS 1638, class 9).
We recommend a filter with
a minimum retention rate of
β
10
≥ 100.
The fitting of filters and regular
replacement of filter elements
guarantees correct operation,
reduces wear and tear and
increases the service life.
2.2.8 Performance graphs
(measured at ν = 65 mm²/s
and t = 30 °C)
Pressure range 070 bar (G24) Pressure range 350 bar (G24)
Pressure range 210 bar (G24)
5
E 5.164.4/03.02
2.2.10 Hysteresis
≤ 4.5 %
2.3. TYPE OF OPERATION
2.3.1 Construction
Electro-magnetic by means of a
pressure resistant core tube
single stroke proportional solenoid
2.3.2 Voltage
DC
2.3.3 Controlling current range
G24: 0 ... 950 mA
2.3.4 Coil resistance
G24: R
20
= 15.3 Ohm
2.3.5 Switching time
100 %
2.3.6 Safety type
IP65 to DIN 40050
for correctly fitted connector
3. DIMENSIONS
PDB 06020
Installation dimensions 06020
PG11 connector can be
displaced by 4 x 90°
fitting depth
2.2.9 Minimum adjustment pressure
A pressure adjustment to a value
below the line is not possible.
Pressure range 070 bar
Pressure range 210 bar
Pressure range 350 bar
min. adjustment pressure (bar) min. adjustment pressure (bar) min. adjustment pressure (bar)
after loosening the knurled nut,
the coil can be rotated through 360°
and removed
Cartridge form tools
Tool Stock No.
Countersink 170033
Reamer 1000768
Tap 1002648
Plug gauge 168840
6
E 5.164.4/03.02
4. CONTROL
ELECTRONICS
4.1 ELECTRONIC AMPLIFIER
TYPE OF CONSTRUCTION
PEK: 19” Euro card system
– plug connector: male multipoint
DIN 41612-D032
– Euro card system
100 x 160 mm
– 6 TE front plate width
(1 TE = 5.08 mm)
– low-loss PDM output stage
– differential input (0-10 V)
with level adjustment
– additional input for direct
potentiometer connection
– 2 independently adjustable
ramp times
– LED display for supply voltage
– base and maximum current
adjustable
– chopper frequency adjustable
PEK
PES PEM
PES: Plug amplifier for
fitting directly onto valve
solenoids
– suitable for fitting onto solenoid
for valve type ...PDB06020
– compact component, can be
separated from the solenoid
system
– low-loss PDM output stage
– differential input (0 - 10 V)
– reverse polarity protected and
short-circuit proof
– LED display for control start
– base, step and maximum current
adjustable
PEM: Amplifier module
– can be mounted onto DIN EN
50022 rail and DIN EN 50035 rail
– compact construction
– replaces terminal strip
– low-loss PDM output stage
– differential input (0 - 10 V)
– reverse polarity protected and
short-circuit proof
– base, step and maximum current
adjustable
7
E 5.164.4/03.02
Standard models:
Please quote stock no. when ordering.
Delivery for non-standard models is longer and the price is higher.
4.3 SUPPLY VOLTAGE
PEK: 24 V DC ± 10 % (permissible residual ripple 49 %)
PES: 20-32 V DC (permissible residual ripple 5 %)
PEM: 20-32 V DC (permissible residual ripple 5 %)
4.4 CURRENT OUTPUT
4.5 REFERENCE INPUT
PEK: 0-10 V DC and direct potentiometer connection
PES: 0-10 V DC
PEM: 0-10 V DC
5. NOTE
The information in this brochure relates to the operating conditions and
applications described.
For applications or operating conditions not described, please contact the
relevant technical department.
Subject to technical modifications.
4.6 DIMENSIONS
PEK
PES
PEM
4.2 MODEL CODE
(also order example)
PES - 01 X - G24
Proportional electronic
amplifier construction
PEK = 19” Euro card system
PES = plug amplifier
PEM = amplifier module
Type
00 = not pre-set
01 = pre-set to suit PDB06020
Series
(determined by manufacturer)
Supply voltage
G24 = 24 V DC
PG threaded connection
4-core cable
approx. 2 m long
Stock no. (= order no.) Model code
479 001 PEK-01X-G24
716 225 PES-01X-G24
479 101 PEM-01X-G24
Amplifier type Base
current (mA)
Step
current (mA)
Maximum
current (A)
Chopper
frequ. (Hz)
Ramp times
up/down (sec)
PEK-00X-G24 0-500 – 0-1.6 50-200 0.1-10/0.1-10
PEK-01X-G24 200 – 0.95 160 0.1-10/0.1-10
PES-00X-G24 0-700 0-600 0-1.6 160 –
PES-01X-G24 200 0 0.95 160 –
PEM-00X-G24 0-700 0-600 0-1.6 160 –
PEM-01X-G24 200 0 0.95 160 –