EN 7.933.4/09.17
141
Filtromat
OF 5
Description
The stationary uid conditioning unit
OF 5 is designed to ll/lter hydraulic
and lubrication tanks and to lter
ofine. A change-over valve on the
unit allows the operator to bypass
the lter when emptying the tank
(optional).
Applications
z Hydraulic and lubrication oil
systems in a variety of industries
Advantages
z Convenient ltration in bypass ow
z Simple handling
z Increased oil and component
service lifetimes
z Reduction of life cycle costs LCC
Technical details
Max. ow rate 30 l/min, 40 l/min
Operating pressure 4.5 bar max.
Viscosity range 15 to 800 mm²/s
(version-dependent)
Permitted operating uid Mineral oil (others on request)
Permissible suction pressure at suction port -0.4 bar to +0.6 bar
Fluid temperature -10 to 80°C
Ambient temperature -20 to 40°C
Seals NBR (option: FPM)
IP class IP 54
Weight (empty) ≈ 46 kg
EN 7.933.4/09.17
142
Model code
OF5 S 10 P 6 N 1 B 05 E
Basic type
OF5
Versions
S = Stationary with change-over valve
N = Ofine unit: stationary without change-over valve
Type code
10 = Standard
Special models on request
Seals
P = NBR (Perbunan)
V = FPM (Viton)
Motor-pump unit
Meas. ref. Theor. output at 1450 rpm Max. viscosity El. motor rating at 50 Hz
3 30 l/min 250 mm²/s 0.75 kW
6 40 l/min 800 mm²/s 1.5 kW
Electric motor voltage
M = 1 x 230 V - 50 Hz
N = 3 x 380-420 V - 50 Hz; 3 x 440-480 V - 60 Hz
S = 3 x 500-600 V - 50 (60) Hz
X = special voltage
Filter size
1 = Element 330
2 = Element 1300
3 = Element 2600
Filter material
B = Betamicron (BN4HC)
A = Aquamicron (BN/AM), (AM)
Filtration rating
03 = 3 µm BN4HC; BN/AM
05 = 5 µm BN4HC
10 = 10 µm BN4HC;BN/AM
20 = 20 µm BN4HC
40 = 40 µm AM
Clogging indicator
E = Standard, back-pressure indicator
B = Option: differential pressure gauge - visual
C = Option: differential pressure gauge - electrical
D = Option: differential pressure gauge - visual/electrical
B, C and D not for version "N"
Dimensions
1
2
2
1
3
Filter element removal height
1 = connections on OF 5 S
2 = connections on OF 5 N
3 = air bleed screw
EN 7.933.4/09.17
143
Hydraulic circuit diagram
OF5 S
I Emptying tank, lter is bypassed A → B
II Filtering ofine A → T
III Filling via lter B → T
OF5 N
Replacement elements
Filter
size
Filtration
rating
Element type Part no.
1 3 µm 0330 R 003 BN4HC/-KB (-V-KB) 1262999 (1263640)
1 5 µm 0330 R 005 BN4HC/-KB (-V-KB) 1263000 (1263641)
1 10 µm 0330 R 010 BN4HC/-KB (-V-KB) 1263001 (1263642)
1 20 µm 0330 R 020 BN4HC/-KB (-V-KB) 1263002 (1263643)
1 40 µm 0330 R 040 AM/-KB (-V-KB) 1272067 (1266563)
1 3 µm 0330 R 003 BN/AM/-KB (-V-KB) 1272069 (1276690)
1 10 µm 0330 R 010 BN/AM/-KB 1272068
2 3 µm 1300 R 003 BN4HC/-KB (-V-KB) 1263059 (1263760)
2 5 µm 1300 R 005 BN4HC/-KB (-V-KB) 1263060 (1263761)
2 10 µm 1300 R 010 BN4HC/-KB (-V-KB) 1263061 (1263762)
2 20 µm 1300 R 020 BN4HC/-KB (-V-KB) 1263062 (1263763)
2 40 µm 1300 R 040 AM/-KB 1267699
2 3 µm 1300 R 003 BN/AM/-KB 1267991
2 10 µm 1300 R 010 BN/AM/-KB (-V-KB) 1270010 (1276060)
3 3 µm 2600 R 003 BN4HC/-KB (-V-KB) 1263071 (1263784)
3 5 µm 2600 R 005 BN4HC/-KB (-V-KB) 1263072 (1263785)
3 10 µm 2600 R 010 BN4HC/-KB (-V-KB) 1263073 (1263786)
3 20 µm 2600 R 020 BN4HC/-KB (-V-KB) 1263074 (1263787)
3 40 µm 2600 R 040 AM/-KB 306899
3 3 µm 2600 R 003 BN/AM/-KB (-V-KB) 1268232 (1275329)
3 10 µm 2600 R 010 BN/AM/-KB 1276840
V = Viton
KB = Without bypass
EN 7.933.4/09.17
144
Note
The information in this general brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the relevant
technical department.
All technical details are subject to change.
HYDAC FILTER SYSTEMS GMBH
Industriegebiet
D-66280 Sulzbach / Saar, Germany
Tel.: +49 (0) 6897/509-01
Fax: +49 (0) 6897/509-9046
Internet: www.hydac.com