421
E 5.050.17/04.17
Fluid Level Gauge
Fluid Level Sensor
Temperature Switch
FSA / FSK / TS
up to NG1000; up to PN 0.5; T = -40 °C to +160 °C
1. DESCRIPTION
1.1. GENERAL
FSA uid level gauges, FSK uid level
sensors and TS temperature switches
are designed to monitor and control the
level of operating uid.
The exible product range means that
many combinations are possible:
FSA: Range of eleven evenly spaced
sizes.
Visual thermometer with °C and °F
scale.
Temperature gauge which measures
the temperature of the operating uid
in the tank in °C. Dual scale in °C and
°F available on request.
Simple standardised installation
conditions.
FSA-IB: shut-off of the uid to the uid
level gauge via non-return valve.
Display of the current level by
simultaneously pressing the upper
and lower buttons on the non-return
valves.
With the optional use of a
thermometer, the current temperature
of the uid will also be shown.
Certied by Bureau Veritas
(BV approval) and by American
Bureau of Shipping (ABS approval).
– FSAR: Fluid level gauge in round
design with pipe connections on both
sides.
Thanks to the principle of
communicating vessels, the gauge
can be attached externally even at
greater distances.
FSK: Monitor the uid level via an
electrical signal.
Range of eleven evenly spaced sizes.
Simple standardised installation
conditions.
Switching contact (sizes 127-381)
designed as optionally normally
closed (type O), normally open (type
C) or changing (type W) contact – as
changing contact (W) in sizes 076 and
500-1000.
Temperature gauge which measures
the temperature of the operating uid
in the tank in °C and °F.
Option: line marking on sight tube and
oat.
Better visual uid level monitoring
possible with red oat.
FSK-2SP: Monitoring of the minimum
or maximum uid level.
Two additional alternative switching
points for size 254 and above.
Optional: line markings on inspection
tube.
FSK-V: Switch points can be
positioned variably, additional
alternative switch points possible.
Switching contact designed as
changing contact, opens or closes at
switching level.
Riser tube made of glass.
Optional, 3-pole AMP plug
(Super Seal).
Optional: line markings on inspection
tube.
TS: three nominal temperatures
possible: 60 °C, 70 °C and 80 °C.
Can be easily tted into the FSA and
FSK.
Simple, standardised mounting
(FSA/K).
Non-corroding surfaces.
Accessories
TFP 100: Temperature sensor with a
measurement range of
-40 °C to +125 °C.
Measuring resistor designed as
4-conductor with standardised
electrical connection.
ABK / ABV: These shut-off elements
allow the connections to be blocked
for maintenance work or for making
changes to the display system (FSA/
FSK), without any tank draining
required.
422
E 5.050.17/04.17
ABK
This stop cock specially designed for the
FSA/FSK has a plug that is guided in a
valve casing and that can be turned from
the outside. Turning it by 90° closes the
connection opening of the FSA/FSK.
It is operated by screwdriver, from the
side, above or below depending on the
position of the ABK.
ABV
Screwing the adjusting screw deeper
into the valve casing closes the
connection opening of the FSA/FSK
(the screw can be loosened again
subsequently).
The screw is adjusted by means of an
allen key (AF width 3).
1.2. FUNCTION
FSA
By using the FSA, the uid level can be
easily seen on the outside of the tank.
The uid enters the unit via the lower
connection bore and is clearly visible in
the tube. By selecting the right size, the
particular uid level can be monitored.
FSK
By using the FSK, the uid level is
monitored via an electrical switching
signal. This switch signal can be used
for a warning or to control the level.
The uid enters the unit via the lower
connection bore and pushes a oat up
the tube. The oat now shows the level
of the uid in the tank. If the level of the
uid drops again, the oat will activate a
switch contact. For the NO switch (type
C) the circuit will then be closed, for the
NC switch (type O) the circuit will be
opened.
The special dual switching model (type
W) offers two possibilities. It can be used
either to close on contact or to open on
contact.
TS
The TS is a very useful additional option
to the FSA and FSK products. However,
it also has a useful application as a
separate accessory for systems.
Once tted, the temperature sensor
of the TS is surrounded by operating
uid. When the nominal temperature is
reached, a contact opens and the circuit
is broken.
This switching process can be used
either as an alarm or to monitor the
temperature.
When the temperature of the uid drops
by approx. 15 K, the circuit closes again.
TFP
Based on the principle of voltage drop,
the sensor provides an electrical signal
as a value for the temperature.
A constant measurement ow is
fed to the temperature sensor. The
voltage change is roughly proportional
to the change in resistance caused
by the temperature – the higher the
temperature, the greater the resistance.
Measurement errors caused by longer
feed lines are avoided by using the
4-conductor connection.
1.3. APPLICATION
Fluid level gauges FSA, uid level
sensors FSK and temperature switches
TS are used to monitor and control levels
of operating uid.
Areas of application are for example:
Machine tools, system engineering, tanks
for hydraulic, lubricating and cutting oils,
and gearboxes.
1.4. NOTES
The upper viscosity limit is 2,000 mm²/s.
It is not possible to combine a TS
temperature switch with an FT
temperature gauge.
To ensure correct functioning, pressure,
viscosity and temperature specications
must be observed.
FSA/FSK
In the standard design not suitable for
use with glycol and uids containing
glycol – the special design SO14 is
recommended as a solution variant in
such cases.
FSK
Depending on the uid level of the tank,
the following switching logic applies for
the uid level monitor with NC and NO
contacts.
Tank uid level
Tank uid level
(normally
closed)
(normally
open)
In each case the switching logic of the
uid level sensor starts with a full tank.
For the NC version the switching contact
opens when the uid level drops below
the switching level. Correspondingly, in
the NO version, the switching contact
closes when the uid level drops below
the switching level.
423
E 5.050.17/04.17
FSA 076 – 2 . X / FT200 / 12 ...
Designation
FSA = fluid level gauge
Nominal size (bolt centre spacing)
076; 127; 176; 254; 381
Seal material
1 = NBR (Perbunan)
2 = FKM (Viton)
5 = EPDM (on request)
Series
(specified by manufacturer)
Additional thermometer function
= no additional function
T = thermometer in display tube
FF = prepared for temperature probe
FT 100 = temperature probe 100 mm
FT 200 = temperature probe 200 mm
FT 300 = temperature probe 300 mm
TS 60 = temperature switch nominal temperature 60 °C
TS 70 = temperature switch nominal temperature 70 °C
TS 80 = temperature switch nominal temperature 80 °C
TFP 100 = temperature probe -40 °C to +125 °C
Installation conditions (Banjo bolt thread)
12 = M12 (standard)
10 = M10 (not on TS)
Special designs
SO2 = with glass tube (round design), aluminium connectors
SO7 = frame, fastening bolts and nuts made from stainless steel*
SO8 = fastening bolts and nuts made from stainless steel*
SO14 = with glass tube, plastic connectors (PA)
SO19 = with green hollow ball, no contrast washer
SO32 = with glass tube (round design), aluminium connectors;
frame, fastening bolts and nuts made from stainless steel*
SO65 = FSA – standard, but without fastening bolts or sealing washers
SO67 = FSA – standard, but without sealing washers
SO79 = with side viewing window
* only for size M12
Fluid level sensor FSK
O - N/C contact
2. TECHNICAL
CHARACTERISTICS
2.1. GENERAL
2.1.1 Designation and Symbol
Fluid level gauge FSA
C - N/O contact
W - N/O or N/C contact
FSA 2542 . 0 / T / 12 SO7/SO78 2xIB
Designation
FSA = fluid level gauge
Nominal size (bolt centre spacing)
076; 127; 176; 254; 381;
500; 600; 700; 800; 900; 1000
Seal material
1 = NBR (Perbunan)
2 = FKM (Viton)
Design of riser tube
0 = round
Additional thermometer function
- = no additional function
T = thermometer
Installation conditions (Banjo bolt thread)
12 = M12
Special designs
SO2 = with glass tube, aluminium connectors and round design
SO7 = frame, fastening bolts and nuts made from stainless steel
SO78 2xIB = with 2x bolts FSA/K-M12 V ISOLATOR bolt
Certification
BV = BV approval (sizes 076–1000)
ABS = ABS approval (sizes 076–381)
2.1.3 Model code for FSA-IB
(also order example)
2.1.2 Model code for FSA
(also order example)
Temperature switch TS
424
E 5.050.17/04.17
FSA - 1000 - 2 . 0 / - / 12 ... Ø19 ...
Designation
FSA = fluid level gauge
Nominal size (bolt centre spacing)
500; 600; 700; 800; 900; 1000
Seal material
1 = NBR (Perbunan)
2 = FKM (Viton)
Design of riser tube
0 = round
Additional thermometer function
= no additional function
FT = temperature probe
Installation conditions (Banjo bolt thread)
12 = M12 (standard)
Tank seal
... = gasket (no entry required)
OR = O-ring
Diameter of riser tube
Ø19 = 19 mm
Special designs
SO2 = with glass tube (round design), aluminium connectors
2.1.4 Model code for FSA 500-1000
(also order example)
FSAR - 137 - 1 . 0 / - / 12LR - 4SF ...
Designation
FSAR = fluid level gauge with pipe connection
Nominal size ( indication range)
088; 137; 215; 342
Seal material
1 = NBR (Perbunan)
2 = FKM (Viton)
Design of riser tube
0 = round
Additional functions
- = hollow ball Ø10
Installation conditions (pipe connection)
12LR = 12LR on both sides
Quantity of viewing windows
4SF = viewable from 4 sides
Design
No details = no fastening nut
MUTTER = with fastening nut
2.1.5 Model code for FSAR
(also order example)
425
E 5.050.17/04.17
FSK - 127 - 2 . X / O / FT200 / 12 / ...
Designation
FSK = Fluid level sensor
Nominal size (bolt centre spacing)
127; 176; 254; 381
Seal material
2 = FKM (Viton)
Series
(specified by manufacturer)
Switching function
O = normally closed opens at the switching level
C = normally open closes at the switching level
W = changing opens or closes at the switching level (connector Z4 = standard)
Additional thermometer function
= no additional function
FT 100 = thermometer probe 100 mm
FT 200 = thermometer probe 200 mm
FT 300 = thermometer probe 300 mm
TSL 60 = temperature switch nominal temperature 60 °C
TSL 70 = temperature switch nominal temperature 70 °C
TSL 80 = temperature switch nominal temperature 80 °C
TFP 100 = temperature probe -40 °C to +125 °C
Installation conditions (Banjo bolt thread)
12 = M12 (standard)
10 = M10 (not on TS)
Connector
No details = 3-pole MPM (standard)
Z4 = 4-pole Hirschmann (standard for changing contact)
SEW = 4-pole M12x1 (sensor connector, horizontal)
SO75 = 3-pole MPM, mounted at top (only size 127)
SES = 4-pole M12x1 (sensor connector, vertical)
Form B = special connection for device connector
2.1.6 Model code for FSK
(also order example)
FSK - 1271 . O / W / – / 12 / 2SP
Designation
FSK = fluid level sensor
FSKV = fluid level sensor with variable switching points
Nominal size (bolt centre spacing)
076; 127; 176; 254; 381
Seal material
1 = NBR (Perbunan)
Series
(specified by manufacturer)
Switching function
W = changing contact, opens or closes at switching level
Additional thermometer function
= no additional function (standard)
Installation conditions (Banjo bolt thread)
12 = M12
Switch points
1SP = 1 switch points
2SP = 2 switch points (1x minimum, 1x maximum) (size 127 and above)
Additional switch points on request
Connector
FSK-076-1SP: 3-pole M8x1 male
FSK-2SP: 5-pole M12x1 male
FSK-V: 3-pole M8x1 male
2.1.7 Model code for FSK-076 / FSK-2SP / FSK-V
(also order example)
426
E 5.050.17/04.17
TS70 / X / 12
Designation
TS = temperature switch (for FSA)
TS-L = temperature switch long (for FSK)
Nominal temperature
60 = 60 °C
70 = 70 °C
80 = 80 °C
Series
(specified by manufacturer)
Installation conditions (Banjo bolt thread)
12 = M12 (standard)
2.1.9 Model code for TS
(also order example)
FSK - 1000 - 1 . 0 / W / - / 12 2SP Ø19 ... ...
Designation
FSK = Fluid level sensor
Nominal size (bolt centre spacing)
500; 600; 700; 800; 900; 1000
Seal material
1 = NBR (Perbunan)
Series
(determined by manufacturer)
Switching function
W = changing contact, opens or closes at switching level
Additional thermometer function
= no additional function
FT = temperature probe
Installation conditions (Banjo bolt thread)
12 = M12 (standard)
Switch points
1SP = 1 switch point
2SP = 2 switch points (1x minimum, 1x maximum)
Additional switch points on request
Diameter of riser tube
Ø19 = 19 mm
Connector
No details = 3-pole M8x1 male (standard)
Special designs
SO2 = with glass tube (round design), aluminium connectors
2.1.8 Model code for FSK 500-1000
(also order example)
427
E 5.050.17/04.17
2.1.10 Type of construction
The devices are designed to be mounted
directly on to the operating uid tank.
2.1.11 Type of connection
FSA / FSK
The device is mounted using two banjo
bolts. The connection bores can be
either threaded holes or through holes
(Ø13, Ø11).
FSAR
The device is mounted via a 12LR pipe
connection on both sides, piping clamp
or retaining plate.
TS
The temperature switch can be tted to
the FSA/FSK in place of the lower banjo
bolt.
2.1.12 Mounting position
FSA vertically on the tank wall
FSK vertically on the tank wall
(connection plug at bottom of the
tank)
TS – instead of lower banjo bolt
M12 (FSA)
TS-L instead of lower banjo bolt
M12 (FSK)
TFP – instead of lower banjo bolt
M12 (FSA/FSK)
2.1.13 Weight
FSK076 - 0.22 kg FSK500 - 0.69 kg
FSK127 - 0.21 kg FSK600 - 0.79 kg
FSK176 - 0.23 kg FSK700 - 0.85 kg
FSK254 - 0.26 kg FSK800 - 0.93 kg
FSK381 - 0.30 kg FSK900 - 1.00 kg
FSK1000 - 1.14 kg
FSA076 - 0.17 kg FSA500 - 0.68 kg
FSA127 - 0.19 kg FSA600 - 0.75 kg
FSA176 - 0.21 kg FSA700 - 0.84 kg
FSA254 - 0.24 kg FSA800 - 0.92 kg
FSA381 - 0.29 kg FSA900 - 0.99 kg
FSA1000 - 1.13 kg
TS-... - 0.11 kg
TS-L-... - 0.13 kg
FT 200 - 0.03 kg
FT 300 - 0.04 kg
TFP 100 - 0.20 kg
2.1.17 FSA seal types
Flat seal (standard)
Quad ring
O-ring
2.1.14 Flow direction
Any
2.1.15 Ambient temperature
-20 °C to +80 °C
2.1.16 Materials
FSA / FSK
Connectors and tube in high quality
synthetic material
Housing frame made from aluminium
(steel or stainless steel on request)
Soft seals in Viton (FKM) or Perbunan
(NBR)
Bolts, nuts and washers in steel
(zinc-plated)
Plug connections in high quality
synthetic material (FSK)
FSA-IB
Housing frame, bolts and nuts made
of stainless steel
Riser tube made of glass Ø19
FSAR
Frame made of aluminium
Riser tube made of glass or plastic
FSA / FSK 500 - 1000
Connectors made of aluminium
Float gauge made from NBR
FSK-2SP
Connectors made of aluminium /
polyamide
Frame made of aluminium
Riser tube made of glass Ø19
FSK-V
Housing frame made of stainless steel
Connectors made of aluminium /
polyamide
Riser tube made of glass Ø19
TS / TS-L / TFP
Housing with temperature sensor,
washer and nut in steel (zinc-plated)
Plug connections in high quality
synthetic material
428
E 5.050.17/04.17
2.2. HYDRAULIC DATA
2.2.1 Nominal pressure
max. 0.5 bar
2.2.2 Operating uids
Mineral oil to DIN 51524 Part 1 and 2,
water-oil emulsions and synthetic uids,
such as hydraulic uids based on
phosphate ester.
(other uids on request)
2.2.3 Temperature of operating uid
-20 °C to +80 °C
2.2.4 Range of thermometer scale
FSA / FSK
Thermometer T for FSA :
+ 20 °C to + 80 °C
Thermometer FT for FSA / FSK :
0 °C to + 100 °C
2.4. ELECTRICAL
CHARACTERISTICS TS / TS-L
2.4.1 Electrical function
N/C contact
2.4.2 Switching power
2.5 A/50 V - 10,000 switching operations
0.5 A/50 V - 100,000 switching operations
2.4.3 Minimum switching current
50 mA
2.4.4 Switching tolerance
± 5 K
2.4.5 Switching hysteresis
Normally closed
60 °C – 10-15 K
70 °C – 10-15 K
80 °C – 10-20 K
2.3.2 Contact load
max. 8 W
2.3.3 Switching voltage
1-48 V AC/DC
2.3.4 Switching current
max. 0.2 A
2.3.5 Protection class
IP 65
2.3.6 Viscosity range
max. 2000 mm²/s
2.3. ELECTRICAL
CHARACTERISTICS FSK
2.3.1 Electrical functions
Type O / normally closed
Type O / normally closed
(plug Z4 and type B)
Type C / normally open
Type W / change over
(connector Z4 and type B)
Type O / normally closed
(plug - SEW)
Type W / change over
(plus - SEW)
1
2
3
2
1
4
2
3
4
1
2
1
3
2
3
1
1
2
3
2
1
4
2
3
4
1
2
1
3
2
3
1
Type W / change over
As delivered, switching point at bottom
activated by magnetic eld.
Size 127, 254, 381
Size 176
Type W / change over
NOTICE: With only one reed contact,
the switch point is at the top or at the
bottom.
Contact assignment
Float setting
bottom top
Minimum 5 - 4 5 - 3
Maximum 5 - 1 5 - 2
Contact assignment
Float setting
bottom top
Minimum 3 - 4 1 - 4
Maximum 1 - 4 3 - 4
Contact assignment
Float setting
top
Maximum 5 - 4
Contact assignment
Float setting
bottom
Minimum 5 - 4
FSK–2SP
FSK–V
429
E 5.050.17/04.17
3. DIMENSIONS
3.1. FLUID LEVEL GAUGE FSA
Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L3
[mm]
F
[mm]
Quantity F
76 37 76 108 - -
127 88 127 159 - -
175 137 176 208 - -
254 215 254 286 - -
381 342 381 413 - -
500 432 500 535 137 3
600 532 600 635 170 3
700 632 700 735 150 4
800 732 800 835 175 4
900 832 900 935 158 5
1000 932 1000 1035 147 6
Tightening torque
8
-0,5
Nm
Nominal size 381
housing with
strengthening bar
FSA standard FSA 500 - 1000
FSA-IB (with non-return valve)
Colour
black
Colour
red
Tightening torque
8
-0,5
Nm
Tightening torque
8
-0,5
Nm
SW17SW18
F
55
34.5
3
6
max. 8
27
M12
L3
L2
L134
10
19
34.3
Tightening
torque
8
-0,5
Nm
430
E 5.050.17/04.17
Design Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L3
[mm]
F
[mm]
G
[mm]
Without nut
FSAR-088 88 141.5 163.5 88 88
FSAR-137 137 190.5 212.5 137 137
FSAR-215 215 268.5 290.5 2x 105 3x 68
FSAR-342 342 395.5 417.5 3x 110.5 4x 82
With nut
FSAR-088 88 139.5 177.5 88 88
FSAR-137 137 188.5 226.5 137 137
FSAR-215 215 266.5 304.5 2x 105 3x 68
FSAR-342 342 393.5 431.5 3x 110.5 4x 82
FSAR without fastening nut FSAR with fastening nut
FSA with temperature switch TS
FSA / FSK with temperature gauge
FSA with temperature gauge
Tightening torque
8
-0,5
Nm
Tightening torque
8
-0,5
Nm
431
E 5.050.17/04.17
3.2. FLUID LEVEL SENSOR FSK
FSK standard
Size 381 housing with
strengthening bar
approx. 55
switching level
Tightening torque
8
-0,5
Nm
tting dimension approx. 74
3
1
4
55
34.5
3 6
max. 8
SW17
SW18
27
M12
37.55
5(72.5)
34.3
18.6
10
F
L1
34
L2
L3
L7
44.5
2
FSK 500 - 1000
approx. 43
Switch point at top
Fluid level
approx. 72
Switch point at bottom
Fluid level
Position the reed contacts
left or right depending on
application
Connection
3-pole plug
M8x1
Bottom reed
contact
Top reed
contact
Tightening
torque
8
-0,5
Nm
Alignment of reed contact
(liquid level increasing)
Alignment of reed contact
(liquid level decreasing)
Type W / changing contact
3-pole connector
M8x1 – male
Liquid level
switching level
Liquid level
switching level
Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L3
[mm]
L7
[mm]
F
[mm]
Quantity F
127 88 127 204 203 - -
176 137 176 253 252 - -
254 215 254 331 330 - -
381 342 381 458 457 - -
500 432 500 535 411 137 3
600 532 600 635 511 170 3
700 632 700 735 611 150 4
800 732 800 835 711 175 4
900 832 900 935 811 158 5
1000 932 1000 1035 911 147 6
432
E 5.050.17/04.17
FSK 076
Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L3
[mm]
127 88 127 219.5
176 137 176 268.5
254 215 254 346.5
381 342 381 473.5
20
31
37
76
108
34.3
19.5
41
+1
19
45
3
25.5 5.5
27
max. 8
M12-SW18
M10-SW 16
1
3
4
Position the reed contact left or
right depending on application
Switching level
uid level
AF width 17
Tightening torque
8
-0,5
Nm
Connection
3-pole plug
M8x1
Connection
3-pole plug
M8x1
Type W / changing contact
FSK plug Z4
Size 381
housing with strengthening
bar
approx. 55
switching level
Tightening torque
8
-0,5
Nm
Fitting dimension approx. 89.5
433
E 5.050.17/04.17
20
31
37
76
108
34.3
19.5
41
+1
19
45
3
25.5 5.5
27
max. 8
M12-SW18
M10-SW 16
1
3
4
Connection
3-pole plug
M8x1
Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L5
[mm]
L6
[mm]
127 88 127 188.5 193.5
176 137 176 237.5 242.5
254 215 254 315.5 320.5
381 342 381 442.5 447.5
FSK sensor connection SEW-M12x1 horizontal
FSK sensor connection SES-M12x1 vertical
Size 381
housing with strengthening bar
Size 381
housing with
strengthening bar
approx. 55
switching level
approx. 55
switching level
Tightening torque
8
-0,5
Nm
Tightening torque
8
-0,5
Nm
4-pole connector
M12x1 – male
4-pole connector
M12x1 – male
434
E 5.050.17/04.17
FSK male connection Form B
FSK with two switch points
Size 381
housing with
strengthening bar
View of switching level
MIN-MAX
NG 381
housing with strengthening bar
NG 254 / NG 381
approx. 55
switching level
Tightening torque
8
-0,5
Nm
tting dimension
approx. 65
Type
Size =
centre distance of bolts
L1
[mm]
L2
[mm]
L3
[mm]
N
[mm]
Approx. S
[mm]
FSK-127-1.0/W/-/12/2SP 127 88 127 159 47.5 77
FSK-176-1.0/W/-/12/2SP 176 137 176 208 96.5 126
FSK-254-1.0/W/-/12/2SP 254 215 254 286 174.5 204
FSK-381-1.0/W/-/12/2SP 381 342 381 413 301.5 331
Nominal size =
centre distance of bolts
L1
[mm]
L2
[mm]
L7
[mm]
127 88 127 203
176 137 176 252
254 215 254 330
381 342 381 457
Connection
5-pole plug
black
red
reed
contact
reed
contact
Fitting dimension
approx. 57
Connector not
supplied
Approx. 31
-2.5
switching point
top
Fluid level
Approx. 48.5
+2,5
switching point
bottom
Fluid level
approx. S
Tightening torque
8
-0,5
Nm
435
E 5.050.17/04.17
Angled connector M8x1 for FSKV
not adjustable
with cable
L = 2 m
adjustable
without cable
FSK with variable switch points
Type Nominal size L0 L1 L2 L3 L4 L5 L6
FSKV-127 127 159 88 127 96 101 40 65
FSKV-176 176 208 137 176 145 150 89 114
FSKV-254 254 286 215 254 223 228 167 192
FSKV-381 381 413 342 381 350 355 294 319
Order no.: 6105865 6105866
approx. 26
-1
switch level MAX
liquid level
approx. 41
+1
switch level
liquid level
Position the reed contacts
left or right depending on
application
Size 381
housing with
strengthening
bar
Colour black
Colour red
Top reed
contact
adjustable
Bottom reed
contact
adjustable
Connection
3-pole plug
Tightening torque
8
-0,5
Nm
SW 18
Tightening torque
8
-0,5
Nm
SW 17
L6 max. adjusting range -2nd contact
mounted on right
L5 min. adjusting range
Alignment of reed contact
(uid level decreasing)
Liquid level
switching level
Alignment of reed contact
(uid level increasing)
Liquid level
switching level
436
E 5.050.17/04.17
4. SPARE PARTS
4.1. SEAL KIT
NOTICE
The information in this brochure relates
to the operating conditions and
applications described.
For applications and operating
conditions not described, please contact
the relevant technical department.
Users bear the responsibility in all cases
for determining the product’s suitability
in the specic application. Quantied
values for product characteristics are
average values for a new product that
undergo a time deterioration process.
Errors and technical changes excepted.
Seal kit Order
no.= Part
number
FSA - 76 - 381 - 1.X /- /12 NBR 704 616
FSA - 76 - 381 - 2.X /- /12 FKM 704 627
FSA - 76 - 381 - 1.X /- /10 NBR 3248767
FSA - 76 - 381 - 2.X /- /10 FKM 3395614
HYDAC Accessories GmbH
Hirschbachstr. 2
66280 Sulzbach/Saar
Tel.: +49 (0)6897 - 509-01
Fax: +49 (0)6897 - 509-1009
Internet: www.hydac.com
E-Mail: info@hydac.com
FSK with temperature switch TS-L
3.3. TEMPERATURE SWITCH TS / TS-L
See FSA with TS tted
See FSK with TS-L tted
3.4. ACCESSORIES
Tightening
torque
8
-0,5
Nm
ABK
ABV
63
8
max. 8
M12
M12
77
23
1.6
M12
°09
15.2
min. 3
SW18
SW22
SW19
Tightening
torque
8
-0,5
Nm
Tightening
torque
8
-0,5
Nm
Turned with allen key
(AF width 03)
Tank
Installation requirement
Sealing nut
Tightening
torque
50 +5
Nm
Open position
switching travel
90°
Closed position
Tank
Tank
max. 8
M12
72
21.6
M12
8
50
SW18SW22
SW18
X
SW03
X (2 : 1)
M12x1
M18x1
48
1,5
M12
23,5
142
7
27
SW19
SW18
Temperature sensor TFP
Tightening torque
8
-0,5
Nm
4-pole connector
M12x1 / M18x1
437
E 5.050.17/04.17