221
EN 18.058.6/02.18
2
Technical data:
Input data
Measuring ranges bar 6 16 40 100 250 400 600 -1 .. 5
Overload pressures bar 15 32 80 200 500 800 1000 15
Burst pressure bar 100 200 200 500 1000 2000 2000 100
Mechanical connection G1/4 A ISO 1179-2
Tightening torque, recommended 20 Nm
Parts in contact with fl uid Mech. connection: Stainless steel
Seal: FKM
Output data
Switching outputs 2 relay contacts
Switching current: 0.01 mA .. 1 A
Switching voltage: 10 mV .. 60 V (AC/DC)
Switching capacity (ohmic resistance): 30 W / 30 VA
Switching cycles (ohmic resistance):
20 million at minimum load
0.5 million at maximum load
Analogue output, permitted load resistance 4 .. 20 mA
Load resist. max. 400 Ω
Accuracy acc. to DIN 16086,
terminal based
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
Temperature compensation, zero point ≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
Temperature compensation, span ≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
Repeatability ≤ ± 0.5 % FS max.
Reaction time approx. 10 ms
Long-term drift ≤ ± 0.3 % FS / year
Environmental conditions
Compensated temperature range -10 .. +70 °C
Operating temperature range -25 .. +80 °C
Storage temperature range -40 .. +80 °C
Fluid temperature range -25 .. +80 °C
mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance acc. to
DIN EN 60068-2-6 at 10 .. 500 Hz
5 .. 25 Hz: 3.2 mm
25 .. 500 Hz: 4 g
Shock resistance acc. to
DIN EN 60068-2-27 (11 ms)
≤ 50 g
Protection class acc. to DIN EN 60529
1)
IP 65
Other data
Supply voltage 20 .. 32 V DC
Residual ripple of supply voltage ≤ 5 %
Current consumption approx. 100 mA
Display 4-digit, LED, 7 segment, red,
height of digits 6.4 mm
Weight ~ 300 g
Note: Reverse polarity protection of the supply voltage, overvoltage, override and short circuit
protection are provided.
FS (Full Scale) = relative to complete measuring range
1)
With mounted mating connector in corresponding protection class
Pressure Switch
EDS 300 shipping applications
Relative pressure Display
Description:
The EDS 300 is a compact, electronic
pressure switch with digital display. The
pressure measurement is based on a strain
gauge sensor cell in stainless steel. All
parts in contact with fl uid are in stainless
steel, and are welded together. Since no
seals are required in the sensor interior,
leakage is eliminated. Two relay switching
outputs with N/O function and an additional
analogue output signal (4 .. 20 mA) enable
the pressure switch to be incorporated into
modern control systems. The switch points
and the corresponding hystereses can easily
be adjusted via the key pad.
For optimum adaptation to a particular
application, the instrument has many
additional setting parameters, e.g. switching
direction of the relays or switching delay
times.
Fields of application are pressure or limit
monitoring on marine transmissions, diesel
engines, pumps and general hydraulic and
pneumatic systems.
Approvals:
●
American Bureau of
Shipping
●
Lloyds Register of
Ships
●
Det Norske Veritas
Germanischer Lloyd
●
Bureau Veritas
Other approvals on request
2 switching outputs
Analogue output
222
EN 18.058.6/02.18
2
Model code:
EDS 3 4 7 – 4 – XXX – SXX
Mechanical connection
4 = G1/4 A ISO 1179-2
Electrical connection
7 = male DIN EN 175201-804, 6 pole + PE
(ZBE 10 mating connector not supplied)
Output
4 = 2 switching outputs and 1 analogue output
Measuring ranges in bar
006; 016; 040; 100; 250; 400; 600
Modication number
S00 = version in bar (except -1 .. 5 bar)
S13 = vacuum version -1 .. 5 bar (in connection with measuring range "006")
Accessories available: (not supplied with instrument)
ZBE 10 mating connector DIN EN 175201-804, 6 pole + PE, right-angle Part no.: 654527
ZBM 300 clamp for wall-mounting - screw-type tting - Part no.: 906385
ZBM 310 clamp for wall-mounting - weld-type tting - Part no.: 6011511
More detailed information on accessories as well as on further accessories such as mating
connectors can be found in the Accessories brochure.
Setting options:
All settings available on the EDS 300 are
grouped in 2 easy-to-navigate menus. In order
to prevent unauthorised adjustment of the
device, a programming lock can be set.
Setting ranges for the
switching outputs:
Switch point function
Measuring
range
in bar
Switch point
in bar
Hysteresis
in bar
Incre-
ment*
in bar
-1 .. 5 -0.85 .. 5 0.05 .. 5.9 0.05
0 .. 6 0.15 .. 6 0.05 .. 5.9 0.05
0 .. 16 0.3 .. 16 0.1 .. 15.8 0.1
0 .. 40 0.6 .. 40 0.2 .. 39.6 0.2
0 .. 100 1.5 .. 100 0.5 .. 99.0 0.5
0 .. 250 3.0 .. 250 1.0 .. 248.0 1.0
0 .. 400 6.0 .. 400 2.0 .. 396.0 2.0
0 .. 600 15.0 .. 600 5.0 .. 590.0 5.0
* All ranges given in the table can be adjusted
by the increments shown.
Additional functions:
●
Scale of the measuring range adjustable (bar
or psi)
●
Switching direction of the relays adjustable
(N/C or N/O function)
●
Switch-on and switch-off delay adjustable
from 0.0 .. 75.0 seconds
●
Choice of display (actual pressure, peak
value, switch point 1, switch point 2, display
off)
●
Subsequent correction of zero point in the
range ± 3 % FS possible
Pin connections:
Note:
The information in this brochure relates to the
operating conditions and applications described.
For applications or operating conditions not
described, please contact the relevant technical
department.
Subject to technical modications.
HYDAC ELECTRONIC GMBH
Hauptstr. 27, 66128 Saarbrücken
Germany
Telephone +49 (0)6897 509-01
Fax +49 (0)6897 509-1726
Internet: www.hydac.com
Hex AF
width 27
Male connector
DIN EN 175201-804
6p +PE
Elastomer prole
seal ring
DIN 3869
Pin EDS 347-4
1 +U
B
2 Centre relay 1 and 2
3 Relay contact 1 (SP1)
4 0 V
5 Analogue
6 Relay contact 2 (SP2)
┴
Housing
DIN EN 175201-804
Dimensions: