221
EN 18.058.6/02.18
2
Technical data:
Input data
Measuring ranges bar 6 16 40 100 250 400 600 -1 .. 5
Overload pressures bar 15 32 80 200 500 800 1000 15
Burst pressure bar 100 200 200 500 1000 2000 2000 100
Mechanical connection G1/4 A ISO 1179-2
Tightening torque, recommended 20 Nm
Parts in contact with fl uid Mech. connection: Stainless steel
Seal: FKM
Output data
Switching outputs 2 relay contacts
Switching current: 0.01 mA .. 1 A
Switching voltage: 10 mV .. 60 V (AC/DC)
Switching capacity (ohmic resistance): 30 W / 30 VA
Switching cycles (ohmic resistance):
20 million at minimum load
0.5 million at maximum load
Analogue output, permitted load resistance 4 .. 20 mA
Load resist. max. 400 Ω
Accuracy acc. to DIN 16086,
terminal based
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
Temperature compensation, zero point ≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
Temperature compensation, span ≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
Repeatability ≤ ± 0.5 % FS max.
Reaction time approx. 10 ms
Long-term drift ≤ ± 0.3 % FS / year
Environmental conditions
Compensated temperature range -10 .. +70 °C
Operating temperature range -25 .. +80 °C
Storage temperature range -40 .. +80 °C
Fluid temperature range -25 .. +80 °C
mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance acc. to
DIN EN 60068-2-6 at 10 .. 500 Hz
5 .. 25 Hz: 3.2 mm
25 .. 500 Hz: 4 g
Shock resistance acc. to
DIN EN 60068-2-27 (11 ms)
≤ 50 g
Protection class acc. to DIN EN 60529
1)
IP 65
Other data
Supply voltage 20 .. 32 V DC
Residual ripple of supply voltage ≤ 5 %
Current consumption approx. 100 mA
Display 4-digit, LED, 7 segment, red,
height of digits 6.4 mm
Weight ~ 300 g
Note: Reverse polarity protection of the supply voltage, overvoltage, override and short circuit
protection are provided.
FS (Full Scale) = relative to complete measuring range
1)
With mounted mating connector in corresponding protection class
Pressure Switch
EDS 300 shipping applications
Relative pressure Display
Description:
The EDS 300 is a compact, electronic
pressure switch with digital display. The
pressure measurement is based on a strain
gauge sensor cell in stainless steel. All
parts in contact with fl uid are in stainless
steel, and are welded together. Since no
seals are required in the sensor interior,
leakage is eliminated. Two relay switching
outputs with N/O function and an additional
analogue output signal (4 .. 20 mA) enable
the pressure switch to be incorporated into
modern control systems. The switch points
and the corresponding hystereses can easily
be adjusted via the key pad.
For optimum adaptation to a particular
application, the instrument has many
additional setting parameters, e.g. switching
direction of the relays or switching delay
times.
Fields of application are pressure or limit
monitoring on marine transmissions, diesel
engines, pumps and general hydraulic and
pneumatic systems.
Approvals:
●
American Bureau of
Shipping
●
Lloyds Register of
Ships
●
Det Norske Veritas
Germanischer Lloyd
●
Bureau Veritas
Other approvals on request
2 switching outputs