1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head with screw-in lter bowl.
Standard equipment:
port for clogging indicator in lter head z
mounting holes in the head z
pressure release/oil drain plug z
(LF 330 and above)
1.2 FILTER ELEMENTS
Hydac lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941 z
ISO 2942 z
ISO 2943 z
ISO 3724 z
ISO 3968 z
ISO 11170 z
ISO 16889 z
Contamination retention capacities in g
Betamicron
®
(BN4HC)
LF 3 µm 5 µm 10 µm 20 µm
30 4.6 5.1 5.4 5.6
60 6.5 7.3 7.8 8.0
110 13.8 15.5 16.4 16.9
160 19.8 22.2 23.5 24.3
240 32.3 36.3 38.4 39.6
330 47.2 53.1 56.1 57.9
660 102.2 114.9 121.5 125.4
Betamicron
®
(BH4HC)
LF 3 µm 5 µm 10 µm 20 µm
30 3.0 2.9 3.2 3.7
60 4.6 4.5 5.0 5.7
110 10.1 9.9 10.9 12.4
160 12.9 12.6 13.9 15.9
240 21.6 21.1 23.2 26.5
330 34.6 33.9 37.2 42.5
660 76.8 75.2 82.6 94.3
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BH4HC): 210 bar
Wire mesh (W): 20 bar
Stainless steel bre (V): 210 bar
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As inline lter
1.6 SPECIAL MODELS AND
ACCESSORIES
bypass valve built into the head, z
separate from the main ow
oil drain plug up to LF 240 z
seals in FPM, EPDM z
test and approval certicates z
1.7 SPARE PARTS
See Original Spare Parts List
1.8 FATIGUE STRENGTH
1.9 CERTIFICATES AND APPROVALS
On request
1.10 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524 z
Lubrication oils DIN 51517, API, z
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506 z
Biodegradable operating uids VDMA z
24568 HETG, HEES, HEPG
Non-am operating uids HFA, HFB, z
HFC and HFD
Operating uids with high water z
content (>50% water content) on
request
1.11 IMPORTANT INFORMATION
Filter housing must be earthed z
When using electrical clogging z
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector
1.3 FILTER SPECIFICATIONS
Nominal pressure 100 bar
Fatigue strength at nominal pressure 10
6
load cycles
from 0 to nominal pressure
(For other pressures, see graph at 1.8)
Temperature range -30 °C to +100 °C
(LF 660: -30 °C to -10 °C: p
max
= 75 bar)
Material of lter head Aluminium
Material of lter bowl Aluminium (LF 660: steel)
Type of clogging indicator VM (differential pressure indicator up to
210 bar operating pressure)
Setting pressure of clogging indicator 5 bar (others on request)
Bypass cracking pressure (optional) 6 bar (others on request)
Symbol for hydraulic systems
LF 30 LF 110 LF 160 LF 240 LF 330 LF 660LF 60
E 7.563.2/02.08