Description
The proportional throttle valves of the series PVD* regulate
a flow rate, dependent on the current, infinitely in 2/2-way-
function. The basic functions 'normally closed' (NC) and
'normally open' (NO) are available. There are 3 valve sizes
available: 11 (max. 25 l/min.), 14 (max. 70 l/min.) and 16
(max. 120 l/min.). Within these sizes fine gradations of flow
are possible. Due to very small tolerances in the piston/
sleeve combination the leakage oil values are extremely
small. The pistons are hardened and grinded, the sleeves
are hardened and honed. This guarantees a service life at
continuous values.
Typical Applications
The proportional throttle valve PVD* is variously applicable. Thus e.g. very cost-effective proportional flow control valves can be
realized in combination with pressure compensators (see EPSR series). Directly built in the pressure port of variable pumps,
energy-saving drives can be conceived by feedback of the consumer pressure (load sensing pumps).
Designs Symbols
There are 4 designs available:
PVDE slip-in cartridge
PVDR with inline body
PVDZ with sandwich body CETOP/ISO 3, 5
PVDES screw-in cartridge
Sizes / Flow Ranges
11 (Piston-∅ 11 mm): 0 to max. 25 l/min
14 (Piston-∅ 14 mm): 0 to max. 70 l/min
16 (Piston-∅ 16 mm): 0 to max. 120 l/min
There are numerous intermediate gradations available.
Hydraulic
Rated Pressure: max. 315 bar
Differencial Pressure: max. 25 bar
Minimum Pressure: Depending on flow rate and
viscosity.
Fluids: oils as per DIN 51524,
others upon request
Viscosity Range: 10 – 350 cSt
Flow Direction: from A to B
Filtration: class 18/16/13, filter ß 6...10 ≥ 75
Hysteresis: < 4% *
* at optimum dither signal between the 20% and 100% values
of the current range
Mechanic
Design: spool type throttle, directly operated
by the solenoid
Ambient Temperature: -25 °C – +50 °C
Fluid Temperature: -25 °C – +70 °C
Installation: no restrictions
Materials: valve parts: steel
seals: NBR, Viton available
backup rings: Teflon, PU
Surface Protection: solenoid: zinc plated
Weight: see dimension sheets
Electrical
Nominal Voltage: 24 V DC; 12 V DC
Rated Current: ∅11: 0,7 A (24 V); 1,7 A (12 V)
∅14: 0,83 A (24 V); 1,66 A (12 V)
∅16: 1,1 A (24 V); 2,2 A (12 V)
Wattage: ∅11: 16 W; ∅14: 20 W; ∅16: 27 W
Cyclic Duration Factor: 100 %
Control Command: PWM-Signal (Pulse-Width-Modulated DC)
Dither Frequency: preferably 140 Hz
Environmental Protection: IP 65
Electrical Termination: plug as per DIN 43650 form A,
incl. square connector Pg9. Socket AMP is
available on request
Control Devices: see chapter 6 'Electronic Amplifiers'
for terms and definitions see chapter 12
3 Sizes
max. 315 bar ● max. 120 l/min
Proportional Throttle Valve PVDE, PVDR, PVDZ, PVD