FLUID TEAM Automationstechnik Gm bH Fon: +49/7531/9748-0 www.fluid-team .com
D-78467 Konstanz Felix-Wankel-Str. 4 Fax: +49/7531/9748-44 info@fluid-team.de
PVD-X-E Date: 03/12 Page 1 of 2 Subject to change © FLUID TEAM GmbH
Description
The proportional throttle valves of the series PVD* regulate
a flow rate, dependent on the current, infinitely in 2/2-way-
function. The basic functions 'normally closed' (NC) and
'normally open' (NO) are available. There are 3 valve sizes
available: 11 (max. 25 l/min.), 14 (max. 70 l/min.) and 16
(max. 120 l/min.). Within these sizes fine gradations of flow
are possible. Due to very small tolerances in the piston/
sleeve combination the leakage oil values are extremely
small. The pistons are hardened and grinded, the sleeves
are hardened and honed. This guarantees a service life at
continuous values.
Typical Applications
The proportional throttle valve PVD* is variously applicable. Thus e.g. very cost-effective proportional flow control valves can be
realized in combination with pressure compensators (see EPSR series). Directly built in the pressure port of variable pumps,
energy-saving drives can be conceived by feedback of the consumer pressure (load sensing pumps).
Designs Symbols
There are 4 designs available:
PVDE slip-in cartridge
PVDR with inline body
PVDZ with sandwich body CETOP/ISO 3, 5
PVDES screw-in cartridge
Sizes / Flow Ranges
11 (Piston-∅ 11 mm): 0 to max. 25 l/min
14 (Piston-∅ 14 mm): 0 to max. 70 l/min
16 (Piston-∅ 16 mm): 0 to max. 120 l/min
There are numerous intermediate gradations available.
Hydraulic
Rated Pressure: max. 315 bar
Differencial Pressure: max. 25 bar
Minimum Pressure: Depending on flow rate and
viscosity.
Fluids: oils as per DIN 51524,
others upon request
Viscosity Range: 10 – 350 cSt
Flow Direction: from A to B
Filtration: class 18/16/13, filter ß 6...10 ≥ 75
Hysteresis: < 4% *
* at optimum dither signal between the 20% and 100% values
of the current range
Mechanic
Design: spool type throttle, directly operated
by the solenoid
Ambient Temperature: -25 °C – +50 °C
Fluid Temperature: -25 °C – +70 °C
Installation: no restrictions
Materials: valve parts: steel
seals: NBR, Viton available
backup rings: Teflon, PU
Surface Protection: solenoid: zinc plated
Weight: see dimension sheets
Electrical
Nominal Voltage: 24 V DC; 12 V DC
Rated Current: ∅11: 0,7 A (24 V); 1,7 A (12 V)
∅14: 0,83 A (24 V); 1,66 A (12 V)
∅16: 1,1 A (24 V); 2,2 A (12 V)
Wattage: ∅11: 16 W; ∅14: 20 W; ∅16: 27 W
Cyclic Duration Factor: 100 %
Control Command: PWM-Signal (Pulse-Width-Modulated DC)
Dither Frequency: preferably 140 Hz
Environmental Protection: IP 65
Electrical Termination: plug as per DIN 43650 form A,
incl. square connector Pg9. Socket AMP is
available on request
Control Devices: see chapter 6 'Electronic Amplifiers'
Technical Data
for terms and definitions see chapter 12
3 Sizes
•
max. 315 bar ● max. 120 l/min
Proportional Throttle Valve PVDE, PVDR, PVDZ, PVD
E
S
FLUID T EAM Automationstechnik Gm bH Fon: +49/7531/9748-0 www.fluid-team.com
D-78467 Konstanz Felix-Wankel-Str. 4 Fax: +49/7531/9748-44 info@fluid-team.de
PVD-X-E Date: 03/12 Page 2 of 2 Subject to change © FLUID TEA M GmbH
Note: Installation of „PVDE2-14/…“: With use in Aluminum bodies, please use bolts M5x65.
Please add an adequate note on your order
*) Guide for Piston Selection
In proportional throttle valves PVD* the throttling area changes with increasing solenoid current. In the normally closed
design the throttling area increases, in the normally open design it decreases. As higher the ∆p (difference pressure)
across the throttle, as more oil flow can pass the respective throttling area. To select the appropriate throttle, the ∆p must
be known. In Load Sensing systems the typical ∆p is 12 to 25bar, in flow control valves with pressure compensators the ∆p
the typical ∆p is 3,5 to 14bar. Higher ∆p values result in a worsening hysteresis.
Please Note: the flow characteristic values of the individual piston types are affected by the housing. The values for the
designs PVDE and PVDR are identical. However, the same piston in a sandwich body (PVDZ) or as screw-in cartridge
(PVDES), can show different characteristics caused by the housing ∆p). Consider as well all other throttle points in the
system (hoses, screw connections, valves)!
On data sheets PVD-11, PVD-14 and PVD-16 the represented characteristics give the following information:
(please contact FLUID TEAM for characteristic curves)
1.) Flow Rate vs. Current (Q/I):
Represent the flow rate resulting in the case of a fixed ∆p-value of 7 bar related to the current.
2.) Difference of Pressure vs. Flow Rate (∆p/Q):
Represent the pressure loss resulting in case of completely opened throttle valve related to the flow rate.
Model Code
PVDR2 –
11 / 2x3,0 –
SG –
1 –
24V –
*
2-Way Proportional Throttle Valve
Piston-∅ / No. of Drillings or
Slots x Drill-∅/Slot Width *)
Rest
Position
Design
Nominal
Voltage
Special
Versions
deliverable executions:
∅
∅∅
∅
normally closed = SG
(intern)
12 V DC
NH = steel-
(mm)
normally open = SO
24 V DC
manual
Slip-in Cartridge PVDE2
override
piston-∅ 11, 14, 16
11 11/ 1x0,8 - SG
2 l/min
24VJ =
(only for
11/ 2x3,0 - SG
12 l/min
AMP jr.
∅ 14)
Inline Body PVDR2
11/ 6x2,0 - SG
25 l/min
piston-∅ 11, 14, 16
11/ 1x1,0 - SO
2 l/min
S = Steel
11/ 4x3,0 - SO
14 l/min
body
Sandwich Body PVDZ2-06
11/ 8x3,0 - SO
20 l/min
(for PVDR2)
CETOP/ISO 3 (in P)
only piston-∅ 11, 14
14 14/ 1x1,0 - SG
5 l/min
14/ 3x3,0 - SG
38 l/min
PVDZ2-10
14/ 6x3,0 - SG
77 l/min
CETOP/ISO 5 (in P)
14/ 2x3,0 - SO
21 l/min
only piston-∅ 16
14/ 4x3,0 - SO
41 l/min
14/ 8x3,0 - SO
55 l/min
Screw-in Cartridge
PVDES2
for cavity T-13A
16 16/ 3x3,0 - SG
50 l/min
only piston-∅ 11
16/ 5x2,5 - SG
70 l/min
16/ 8x2,5 - SG
100 l/min
for cavity T-5A
16/ 6x5,0 - SO
120 l/min
only piston-∅ 14
(in the case of a fixed ∆p-value of 7 bar)
Other pistons are available on request.
Please contact FLUID TEAM for
appropriate selection of the throttle.
*)