Pressure Filter
Series HPF 60-450
4568 PSI
Description:
Pressure filter series HPF 60-450 have a working
pressure up to 4568 PSI. Pressure peaks can be
absorbed with a sufficient safety margin. The HPF-
filters are flanged to the mounting-surface.
The filter element consists of star-shaped, pleated filter
material, which is supported on the inside by a
perforated core tube and is bonded to the end caps
with a high-quality adhesive. The flow direction is from
outside to inside. Filter elements are available down to
5 µm
(c)
. Finer filtration is available upon request.
Eaton filter elements are known for high intrinsic
stability and an excellent filtration capability, a high
dirt-retaining capacity and a long service life.
Eaton filter elements are suitable for all petroleum
based fluids, HW-emulsions, most synthetic hydraulic
fluids and lubrication oils.
Eaton filter elements are available up to a pressure
resistance of p 2320 PSI and a rupture strength ofp
3625 PSI.
The internal valve is integrated into the filter head.
After reaching the bypass pressure setting, the bypass
valve will send unfiltered partial flow around the filter.
The reversing valve provides another level of
protection for the filter element. The reverse flow will
not be filtered.
1. Type index:
1.1. Complete filter: (ordering example)
HPF. 90. 10VG. HR. E. P. -. F. 4. -. -. AE
1 2 3 4 5 6 7 8 9 10 11 12
1 series:
HPF = pressure filter, manifold mounted
2 nominal size: 60, 90, 150, 170, 240, 360, 450
3 filter-material and filter-fineness:
80G, 40G, 25G, 10G stainless steel wire mesh
25VG, 16VG, 10VG, 6VG, 3VG glass fiber
4 filter element collapse rating:
30 =
p 435 PSI
HR =
p 2320 PSI (rupture strength p 3625 PSI)
5 filter element design:
E = single-end open
6 sealing material:
P = Nitrile (NBR)
V = Viton (FPM)
7 filter element specification: (see catalog)
- = standard
VA = stainless steel
IS06 = for HFC applications, see sheet-no. 31601
8 process connection:
F = manifold mounted
9 process connection size:
4 = ¾“ (HPF 60-150)
5 = 1“ (HPF 170-450)
10 filter housing specification: (see catalog)
- = standard
IS06 = for HFC applications, see sheet no.31605
11 internal valve:
- = without
S1 =
with bypass valve
p 51 PSI
S2 =
with bypass valve
p 102 PSI
R = reversing valve, Q ≤ 18.50 GPM (HPF 60-150)
reversing valve, Q ≤ 55.75 GPM (HPF 170-450)
12 clogging indicator or clogging sensor:
- = without
AOR = visual, see sheet-no. 1606
AOC = visual, see sheet-no. 1606
AE = visual-electric, see sheet-no. 1615
VS5 = electronic, see sheet-no. 1619
To add an indicator to your filter, use the corresponding indicator data
sheet to find the indicator details and add them to the filter assembly
model code.
1.2. Filter element:
(ordering example)
01E. 90. 10VG. HR. E. P. -
1 2 3 4 5 6 7
1 series:
01E. = filter element according to company standard
2 nominal size: 60, 90, 150, 170, 240, 360, 450
3 - 7 see type index-complete filter