EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-570.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
VF1-10/VF11-10 - Velocity Fuse
23 L/min (6 USgpm) • Up to 350 bar (5000 psi)
Operation
This valve is normally open
from port 1 to port 2. When
flow exceeds the setting of
the valve, it closes. The valve
returns to the open condition
when the pressure at port 1 is
reduced to less than 80 psi.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Description
This is a screw in cartridge
velocity fuse used to lock a
cylinder or motor in place in
the case of a complete hose
failure.
Sectional View
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi)
Rated Flow 23 L/min (6 USgpm)
Flow regulation accuracy 1,9–22,7 L/min (0.5–6.0 USgpm) ±20%
Factory set maximum flow rate accuracy under
standard test conditions and within the above ranges
Internal leakage Port 2 to 1; <5 drops/min, maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20, etc
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminium or steel
Weight 0,11 kg (0.25 lbs)
Seal kit 565803 (Buna-N)
566086 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
A - 22,8 L/min (6 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
B - 14,44 L/min (3 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
C - 3,8 L/min (1 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
30
25
20
15
10
5
0 7 10 14 17 20
0 45 100 150 200 250
8
6
4
2
0
Pressure drop - psi
Pressure drop - bar
A
B
C
300
3
Flow - L/min
(21,8 cSt oil @ 49°C)
Flow - USgpm
(105 SUS oil @ 120°F)
Pressure Drop
Cartridge only
Note: The valve is not intended
for use in pump unloading
applications
2
1
Fusing direction
Reverse
flow direction
2
1
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-571.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
VF1-10/VF11-10 - Velocity Fuse
23 L/min (6 USgpm) • Up to 350 bar (5000 psi)
Model Code
1
Function
VF1 - Velocity fuse 210 bar
(3000 psi)
VF11 - Velocity fuse 350 bar
(5000 psi)
2
Size
10 - Size
3
Seals
N or Blank - Buna-N
V - Viton
®
4
Adjustment
F - Fixed orice
2 3 4 51
VF(*)1 10 (V) F **
Code Port Size Housing Number
Aluminium Aluminium Steel
Light Duty Fatigue Rated
0 Cartridge only
(A)3B 3/8" BSPP 02–175462 – –
(A)6T SAE 6 566151 – –
(A)2G 1/4" BSPP – 876702 –
(A)3G 3/8" BSPP – 876703 –
(A)6H SAE 6 – 876700 –
(A)8H SAE 8 – 876701 –
S6T SAE 6 – – 02-175100
S8T SAE 8 – – 02-175101
S2G 1/4” BSPP – – 02-175102
S3G 3/8” BSPP – – 02-175103
See section J for housing details.
5
Port Size
6
Factory Set Flow Rate
(Specify in USgpm) Range
1,9-22,7 L/min ((0.5 - 6.0 USgpm)
7
Special Features
00 - None
(Only required if valve has special
features, omitted if "00".)
•
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
6
*.*
7
00
Dimensions
mm (inch)
Cartridge Only
Basic Code
VF1/11
Torque cartridge in housing:
A - 47-54 Nm (35-40 ft lbs)
S - 68-75 Nm (50-55 ft lbs)
19,0
(0.75)
ø15,82 (0.623)
0.875"-14 Thd.
25,4 (1.00) hex
31,7
(1.25)
2
1
2
1
0.81
(20.7)
1.25
(31.7)
0.875"-14 Thd.
.62 (15.8)
Installation Drawing (Steel)
– – –– –
63.5
(2.50)
50.8
(2.00)
28.6
(1.13)
76.2
(3.00)
22.2
(0.87)
95
(0.37)
44.45
(1.75)
2 X Ø7.14
(0.281)
44.45
(1.75)
19
(0.75)