EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-390.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
FCV11-12 - Flow Restrictor Valve
Needle
114 L/min • 350 bar (5000 psi)
Operation
This needle valve is a variable
orifice used to create a pressure
drop when flow passes from
port 1 to 2 or port 2 to 1.
Clockwise rotation of the adjust
screw de-creases the orifice size
to completely closed and anti-
clockwise increases the orifice.
The setting can be locked using
the lock nut on the adjust screw.
Features
Hardened and ground working
components. Cartridge
construction for maximum
mounting flexibility.
20 40 60 80 100
6,21
5,52
4,83
4,14
3,45
2,5
2,0
1,0
0,5
302520151050
0
10
20
30
40
50
60
70
80
90
Flow - L/min (21,8 cSt oil @ 49°C)
Pressure drop - bar
Pressure drop - psi
A
B
C
Flow - USgpm (105 SUS @ 120°F)
Description
This is a manually adjusted
cartridge type needle valve. With
fine control it is ideal for none
compensated speed control of
actuators or as a control orifice
in conjunction with a pressure
compensator Total shut off can
be achieved allowing the valve to
be used as a shut of valve.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) Port “1” to “2”
210 bar (3000 psi) Port “1” to “2”
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Internal leakage less than 5 drops/min maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-2 or C-12-2U
Fluids All general purpose hydraulic fluids such as
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum or steel
Weight cartridge only 0,24 kg (0.54 lbs)
Seal kit 2–165889 (Buna-N)
02–165888 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
Pressure Drop Curves
Cartridge only
A - Cartridge with C-12-2 valve body, full open
B - Cartridge with C-12-2U valve body, full open
C - Cartridge only, full open
1
2
1
2
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-391.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
FCV11-12 - Flow Restrictor Valve
Needle
114 L/min • 350 bar (5000 psi)
Code Port Size Housing Number
C-12-2U C-12-2 C-12-2U C-12-2
Aluminium Aluminium Steel Steel
Fatigue rated Fatigue rated Fatigue rated Fatigue rated
0 Cartridge only
10T(U) SAE 10 02–160641 02–160640 02–169817 02–169744
12T(U) SAE 12 02–160645 02–160644 02v169790 02–169782
4G(U) 1/2" BSPP 02–161116 02–161118 02–172512 02–172062
6G(U) 3/4" BSPP 02–161115 02–161117 02–162922 02–169665
See section J for housing details.
1
Function
FCV11 - Flow control valve
2
Size
12 - 12 size
3
Seal Material
Blank - Buna-N
V - Viton
®
4
Adjustment
S - Screw
K - Knob
5
Valve Housing Material
Blank - No body
A - Aluminum
S - Steel
44,6
(1.80)
31,8 (1.25) hex
1.063"–12
Thd.
2
1
Ø23,75 (0.935)
"S" Adjustment
3,2 (0.12) hex
40,0
(1.60)
Dimensions
mm (inch)
Model Code
2 31
FCV11
12
(V)
5
*
6
***
4
S
6
Port Size
8
NV
9
00
7
(U)
7
Cavity
Blank – Cavity without undercut
U – Cavity with undercut
8
Valve Type
NV – Needle Valve
(Adjustable)
9
Special Features
00 - None
(Only required if valve has special
features, omit if ("00")
Torque cartridge in housing
A - 81–95 Nm (60–70 ft lbs)
S - 102–115 Nm (75–85 ft lbs)
Cartridge Only
Basic Code
FCV11-12
•
WARNING
Aluminum housings
can be used for pressures up
to 210 bar (3000 psi). Steel
housings must be used for
operating pressures above 210
bar (3000 psi).
Installation Drawing (Steel)
– – –– – – –
12.7
(0.50)
63.5
(2.500)
63.5
(2.500)
88.9
(3.50)
88.9
(3.50)
28.7
(1.13)
20.7
(0.81)
2 X Ø 10.31
(0.46)
25.4
(1.00)
50.8
(2.00)
1
2