EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009A-200.A
An Eaton Brand
A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 114 L/min (30 USgpm)
Internal leakage less than 5 drops/min, max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-2 or C-12-2U
Add “U” after number if undercut is required. If undercut is not specified,
expect 10 psi @ 15 USgpm and 20 psi @ 30 USgpm higher pressure drop.
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/16/13
Housing material (standard) Steel
Weight cartridge only 0,27 kg (0.59 lbs)
Seal kit 02-165889 (Buna-N), 02-165888 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
SV13-12-C/CM - Solenoid Valve
2-way, 2-position, normally closed, poppet type solenoid valve
114 L/min (30 USgpm) • 350 bar (5000 psi)
Description
This is a 2-way, 2-position,
poppet type, high pressure,
pilot operated, normally closed
solenoid valve. This valve is
used in applications requir-
ing low leakage, such as load
holding applications or as a
general purpose diverter or
dump valve.
Operation
In the de-energized position
the valve blocks flow from port
2 to 1 and free flow is allowed
from port 1 to 2.
When the solenoid is ener-
gized the pilot poppet is pulled
off the seat allowing the valve
to open in both directions.
Features
Hardened and ground work-
ing parts. Lapped seat for low
leakage. IP69K Tough coil com-
patibility. Continuously rated.
Compact design with low
pressure drop. 350 bar work-
ing pressure.
Performance Data
Sectional View
Pressure Drop
Cartridge only
A - Port 1 to port 2
B - Port 2 to port 1 energized
2
1
Pressure Drop - psi
25
0
50
75
100
125
150
175
Pressure D rop - bar
1
3
5
7
9
11
Flow - L/m in (21,8 cSt oil @ 49°C)
95 114765738180
Flow - U Sgpm (105 SU S oil @ 120°F)
0 5 10 15 20 25 30
A
B
1
2
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 A-201.A
An Eaton Brand
A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
2X 10.31
(.406)
88.9
(3.50)
88.9 (3.50)
63.5 (2.50)
63.5
(2.50)
12.7
(.50)
60.3
(2.37)
12.7
(.50)
28.7
(1.13)
25.4
(1.00)
2
1
Dimensions
mm (inch)
Torque cartridge in housing
A - 81-95 Nm (60-70 ft lbs)
S - 102-115 Nm (75-85 ft lbs)
Note: When solenoid valve is
ordered as cartridge only, coil
nut is included.
Note: For applications above
210 bar please consult our
technical department or use the
steel body option.
SV13-12-C/CM - Solenoid Valve
2-way, 2-position, normally closed, poppet type solenoid valve
114 L/min (30 USgpm) • 350 bar (5000 psi)
1
Function
SV13 - Solenoid valve
2
Size
12 - 12 size
3
Seal Material
Blank - Buna-N
V - Viton
®
4
Style
C - Normally closed
5
Manual Override Option
Blank - No manual override
M - Manual override
For valve dimensions with
manual override option installed
see page A-980.
6
Valve Housing Material
Blank - Cartridge only
A - Aluminum
S - Steel (standard)
Code Port Size Housing Number
Aluminium Steel
0 Cartridge only
4G 1/2" BSPP 02-161118 02-172062
4GU 1/2" BSPP 02-161116 02-172512
6G 3/4" BSPP 02-161117 02-169665
6GU 3/4" BSPP 02-161115 02-162922
10T SAE 10 02-160640 02-169744
10TU SAE 10 02-160641 02-169817
12T SAE 12 02-160644 02-169782
12TU SAE 12 02-160645 02-169790
See section J for housing details.
7
Port Size
8
Voltage Rating
00 - No coil
12D - 12VDC
24D - 24VDC
36D - 36VDC
24A - 24VAC
115A - 115VAC
230A - 230VAC
12B - 12VDC/w diode*
24B - 24VDC/w diode*
*Optional arc suppression diode.
9
Connector Types
Blank - No coil
G - ISO 4400 DIN 43650
Q - Spade terminals
W - Flying lead
N - Deutsch (DC only)
Y - Amp JR (DC only)
D - Metripack 150 male
(DC only)
J - Metripack 280 male
(DC only)
10
Coil Series
H - 10 series, 29 W
For coil part numbers and dimensions
see section C.
11
Special Features
00 - None
(Only required if valve has special
features, omitted if “00.”)
Model Code
2 3 4 5 6 8 9 101
SV13 12 (V) C (M) (S) **** * H
7
**
11
00
Installation Drawing (Steel)Cartridge Only
WARNING
Maintain 5-8 Nm
(4-6 ft lbs) maximum
torque on valve tube nut.
Over tightening may cause
valve failure.
•
–
– – –
–